{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/59699"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/59699","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"THE IMPACT OF TECHNOLOGIES AND MISSIONS ON CONTINGENCY BASE FUEL CONSUMPTION","abstract":"Fossil fuels satisfy the bulk of the U.S. military's energy requirements for transportation and sustainment needs. In recent years, deployments to Operation Enduring Freedom (OEF), Operation Iraqi Freedom (OIF), and Operation Inherent Resolve (OIR) have highlighted inefficiencies in how the U.S. military generates electrical power. Many strategies have been proposed to unleash the U.S. military from the tether of fuel. This paper presents a mixed integer linear program to minimize the fuel needed to meet power requirements at a contingency base over a 24-hour period. The paper then assesses the impact on fuel consumption and generator run-hours of introducing energy storage systems and photovoltaic arrays to different power demand scenarios based on the mission, geographic, and seasonal parameters. Removing the traditional requirement for spinning reserves and allowing generators to operate at 100% of their rated load resulted in substantial reductions in generator run-hours across all scenarios. The results showed that adding an energy storage system had effectively no impact on generator run-hours or fuel consumption, and that the impact of adding a photovoltaic array was highly dependent upon the latitude and season in which the contingency base was established. The author concludes that diesel and JP-8 are the best methods for storing energy at a contingency base, and that reducing energy demand is the most direct way to reduce fuel consumption and generator run-hours.","abstract_html":"Fossil fuels satisfy the bulk of the U.S. military&#x27;s energy requirements for transportation and sustainment needs. In recent years, deployments to Operation Enduring Freedom (OEF), Operation Iraqi Freedom (OIF), and Operation Inherent Resolve (OIR) have highlighted inefficiencies in how the U.S. military generates electrical power. Many strategies have been proposed to unleash the U.S. military from the tether of fuel. This paper presents a mixed integer linear program to minimize the fuel needed to meet power requirements at a contingency base over a 24-hour period. The paper then assesses the impact on fuel consumption and generator run-hours of introducing energy storage systems and photovoltaic arrays to different power demand scenarios based on the mission, geographic, and seasonal parameters. Removing the traditional requirement for spinning reserves and allowing generators to operate at 100% of their rated load resulted in substantial reductions in generator run-hours across all scenarios. The results showed that adding an energy storage system had effectively no impact on generator run-hours or fuel consumption, and that the impact of adding a photovoltaic array was highly dependent upon the latitude and season in which the contingency base was established. The author concludes that diesel and JP-8 are the best methods for storing energy at a contingency base, and that reducing energy demand is the most direct way to reduce fuel consumption and generator run-hours.","abstract_has_math":false,"creators":["Kiser, Erik"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Applied Mathematics","degree_level":"Masters","degree_discipline":"Applied Mathematics","degree_department":"Applied Mathematics (MA)","school":null,"contributors":[],"advisors":["Krener, Arthur J."],"committee_chairs":[],"committee_members":["Zhou, Hong"],"year":2018,"date_issued":"2018-06","date_published":"2018-06","updated_at":"2026-11-24T23:52:31Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["30532"],"render_values":[{"text":"30532","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/59699","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/59699","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F59699","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Krener, Arthur J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Zhou, Hong"]},{"key":"dc:contributor.department","label":"Department","values":["Applied Mathematics (MA)"]},{"key":"dc:creator","label":"Author","values":["Kiser, Erik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-08-24T22:35:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-24T22:35:54Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Mathematics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Mathematics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["30532"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["energy","energy storage","generator","fuel","photovoltaic","model predictive control","numerical optimization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/59699"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fossil fuels satisfy the bulk of the U.S. military's energy requirements for transportation and sustainment needs. In recent years, deployments to Operation Enduring Freedom (OEF), Operation Iraqi Freedom (OIF), and Operation Inherent Resolve (OIR) have highlighted inefficiencies in how the U.S. military generates electrical power. Many strategies have been proposed to unleash the U.S. military from the tether of fuel. This paper presents a mixed integer linear program to minimize the fuel needed to meet power requirements at a contingency base over a 24-hour period. The paper then assesses the impact on fuel consumption and generator run-hours of introducing energy storage systems and photovoltaic arrays to different power demand scenarios based on the mission, geographic, and seasonal parameters. Removing the traditional requirement for spinning reserves and allowing generators to operate at 100% of their rated load resulted in substantial reductions in generator run-hours across all scenarios. The results showed that adding an energy storage system had effectively no impact on generator run-hours or fuel consumption, and that the impact of adding a photovoltaic array was highly dependent upon the latitude and season in which the contingency base was established. The author concludes that diesel and JP-8 are the best methods for storing energy at a contingency base, and that reducing energy demand is the most direct way to reduce fuel consumption and generator run-hours."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theimpactoftechn1094559699"]},{"key":"dc:title","label":"Title","values":["THE IMPACT OF TECHNOLOGIES AND MISSIONS ON CONTINGENCY BASE FUEL CONSUMPTION"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Krener, Arthur J."],"dc:contributor.committeemember":["Zhou, Hong"],"dc:contributor.department":["Applied Mathematics (MA)"],"dc:creator":["Kiser, Erik"],"dc:date.accessioned":["2018-08-24T22:35:54Z"],"dc:date.available":["2018-08-24T22:35:54Z"],"dc:date.issued":["2018-06"],"dc:description.abstract":["Fossil fuels satisfy the bulk of the U.S. military's energy requirements for transportation and sustainment needs. In recent years, deployments to Operation Enduring Freedom (OEF), Operation Iraqi Freedom (OIF), and Operation Inherent Resolve (OIR) have highlighted inefficiencies in how the U.S. military generates electrical power. Many strategies have been proposed to unleash the U.S. military from the tether of fuel. This paper presents a mixed integer linear program to minimize the fuel needed to meet power requirements at a contingency base over a 24-hour period. The paper then assesses the impact on fuel consumption and generator run-hours of introducing energy storage systems and photovoltaic arrays to different power demand scenarios based on the mission, geographic, and seasonal parameters. Removing the traditional requirement for spinning reserves and allowing generators to operate at 100% of their rated load resulted in substantial reductions in generator run-hours across all scenarios. The results showed that adding an energy storage system had effectively no impact on generator run-hours or fuel consumption, and that the impact of adding a photovoltaic array was highly dependent upon the latitude and season in which the contingency base was established. The author concludes that diesel and JP-8 are the best methods for storing energy at a contingency base, and that reducing energy demand is the most direct way to reduce fuel consumption and generator run-hours."],"dc:description.uri":["http://archive.org/details/theimpactoftechn1094559699"],"dc:identifier.uri":["https://hdl.handle.net/10945/59699"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["energy","energy storage","generator","fuel","photovoltaic","model predictive control","numerical optimization"],"dc:title":["THE IMPACT OF TECHNOLOGIES AND MISSIONS ON CONTINGENCY BASE FUEL CONSUMPTION"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Army"],"thesis:degree_discipline":["Applied Mathematics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Applied Mathematics"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["30532"]},"updated_at":"2026-11-24T23:52:31Z"}