{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/59700"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/59700","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"INDUSTRIAL AUTOMATION OF SOLAR-POWERED HYDROGEN GENERATION PLANT","abstract":"This study combined and modified designs of solar-powered hydrogen generation and compression facilities in order to allow for continuous autonomous operation of a 100-percent renewable hydrogen system. The hydrogen generation autonomous operating system was built and tested including assembly, programming, and operation. Utilizing a total system design approach in order to achieve long-term operation without human intervention was key. The design was based around an industrial-type programmable logic controller. It included limiting the number of sensors and controls to improve reliability. Commercial-off-the-shelf components were used due to their proven reliability, accuracy, and durability. Designed-in system safety features include smoke detectors, oxygen and hydrogen sensors, and emergency shutdown pushbuttons, which trigger emergency shutdown if an unsafe condition occurs. The final generation system was operated continuously for nine days to prove design robustness and to provide data for system validation and improvement. Modifications to system programming and changes in sensors and controls will improve efficiencies. New developments in water distillation, dehumidification, and purification can be easily added to improve efficiency and provide the necessary water for continuous system operation. Implementation of the hydrogen compression automation system will be extremely useful in providing fuel for future projects such as a hydrogen-powered gas turbine.","abstract_html":"This study combined and modified designs of solar-powered hydrogen generation and compression facilities in order to allow for continuous autonomous operation of a 100-percent renewable hydrogen system. The hydrogen generation autonomous operating system was built and tested including assembly, programming, and operation. Utilizing a total system design approach in order to achieve long-term operation without human intervention was key. The design was based around an industrial-type programmable logic controller. It included limiting the number of sensors and controls to improve reliability. Commercial-off-the-shelf components were used due to their proven reliability, accuracy, and durability. Designed-in system safety features include smoke detectors, oxygen and hydrogen sensors, and emergency shutdown pushbuttons, which trigger emergency shutdown if an unsafe condition occurs. The final generation system was operated continuously for nine days to prove design robustness and to provide data for system validation and improvement. Modifications to system programming and changes in sensors and controls will improve efficiencies. New developments in water distillation, dehumidification, and purification can be easily added to improve efficiency and provide the necessary water for continuous system operation. Implementation of the hydrogen compression automation system will be extremely useful in providing fuel for future projects such as a hydrogen-powered gas turbine.","abstract_has_math":false,"creators":["Birkemeier, Scott M."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical and Aerospace Engineering (MAE)","school":null,"contributors":[],"advisors":["Gannon, Anthony J.","Holmes, Andrea D."],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-06","date_published":"2018-06","updated_at":"2026-11-26T00:12:20Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["29750"],"render_values":[{"text":"29750","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/59700","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/59700","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F59700","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F59700","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gannon, Anthony J.","Holmes, Andrea D."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical and Aerospace Engineering (MAE)"]},{"key":"dc:creator","label":"Author","values":["Birkemeier, Scott M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-08-24T22:35:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-24T22:35:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["29750"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["hydrogen","automation","sensors","controls","renewable"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/59700"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study combined and modified designs of solar-powered hydrogen generation and compression facilities in order to allow for continuous autonomous operation of a 100-percent renewable hydrogen system. The hydrogen generation autonomous operating system was built and tested including assembly, programming, and operation. Utilizing a total system design approach in order to achieve long-term operation without human intervention was key. The design was based around an industrial-type programmable logic controller. It included limiting the number of sensors and controls to improve reliability. Commercial-off-the-shelf components were used due to their proven reliability, accuracy, and durability. Designed-in system safety features include smoke detectors, oxygen and hydrogen sensors, and emergency shutdown pushbuttons, which trigger emergency shutdown if an unsafe condition occurs. The final generation system was operated continuously for nine days to prove design robustness and to provide data for system validation and improvement. Modifications to system programming and changes in sensors and controls will improve efficiencies. New developments in water distillation, dehumidification, and purification can be easily added to improve efficiency and provide the necessary water for continuous system operation. Implementation of the hydrogen compression automation system will be extremely useful in providing fuel for future projects such as a hydrogen-powered gas turbine."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/industrialautoma1094559700"]},{"key":"dc:title","label":"Title","values":["INDUSTRIAL AUTOMATION OF SOLAR-POWERED HYDROGEN GENERATION PLANT"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gannon, Anthony J.","Holmes, Andrea D."],"dc:contributor.department":["Mechanical and Aerospace Engineering (MAE)"],"dc:creator":["Birkemeier, Scott M."],"dc:date.accessioned":["2018-08-24T22:35:55Z"],"dc:date.available":["2018-08-24T22:35:55Z"],"dc:date.issued":["2018-06"],"dc:description.abstract":["This study combined and modified designs of solar-powered hydrogen generation and compression facilities in order to allow for continuous autonomous operation of a 100-percent renewable hydrogen system. The hydrogen generation autonomous operating system was built and tested including assembly, programming, and operation. Utilizing a total system design approach in order to achieve long-term operation without human intervention was key. The design was based around an industrial-type programmable logic controller. It included limiting the number of sensors and controls to improve reliability. Commercial-off-the-shelf components were used due to their proven reliability, accuracy, and durability. Designed-in system safety features include smoke detectors, oxygen and hydrogen sensors, and emergency shutdown pushbuttons, which trigger emergency shutdown if an unsafe condition occurs. The final generation system was operated continuously for nine days to prove design robustness and to provide data for system validation and improvement. Modifications to system programming and changes in sensors and controls will improve efficiencies. New developments in water distillation, dehumidification, and purification can be easily added to improve efficiency and provide the necessary water for continuous system operation. Implementation of the hydrogen compression automation system will be extremely useful in providing fuel for future projects such as a hydrogen-powered gas turbine."],"dc:description.award":["Outstanding Thesis"],"dc:description.uri":["http://archive.org/details/industrialautoma1094559700"],"dc:identifier.uri":["https://hdl.handle.net/10945/59700"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["hydrogen","automation","sensors","controls","renewable"],"dc:title":["INDUSTRIAL AUTOMATION OF SOLAR-POWERED HYDROGEN GENERATION PLANT"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["29750"]},"updated_at":"2026-11-26T00:12:20Z"}