{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/60348"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/60348","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"ASSESSMENT ON RADIATED SUSCEPTIBILITY TESTING WITHIN THE DOD AND INDUSTRY","abstract":"The war on terrorism has been a major driving factor for warfighter use of commercial off-the-shelf (COTS) items. Multiple COTS products have been introduced in the field that have been tested to industry standards, immunity testing, rather than to Department of Defense (DoD) military standards—a subset for Electromagnetic Environmental Effects (E3) testing called Radiated Susceptibility (RS) 103 testing, and External Radio Frequency Electromagnetic Environment (External RF EME) testing. The DoD needs to determine the minimum acceptable test for radiated susceptibility (RS)/Immunity in order to determine the risk, if any, to the operators using these products in the field. Many of the COTS products that have been introduced for DoD use were purportedly assessed to a military specification while being tested to an industry test. This thesis assesses the difference between DoD and industry RS/Immunity testing to determine the worst-case test scenario for ground systems.","abstract_html":"The war on terrorism has been a major driving factor for warfighter use of commercial off-the-shelf (COTS) items. Multiple COTS products have been introduced in the field that have been tested to industry standards, immunity testing, rather than to Department of Defense (DoD) military standards—a subset for Electromagnetic Environmental Effects (E3) testing called Radiated Susceptibility (RS) 103 testing, and External Radio Frequency Electromagnetic Environment (External RF EME) testing. The DoD needs to determine the minimum acceptable test for radiated susceptibility (RS)/Immunity in order to determine the risk, if any, to the operators using these products in the field. Many of the COTS products that have been introduced for DoD use were purportedly assessed to a military specification while being tested to an industry test. This thesis assesses the difference between DoD and industry RS/Immunity testing to determine the worst-case test scenario for ground systems.","abstract_has_math":false,"creators":["Solis, Carlos G."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Systems Engineering Management","degree_level":"Masters","degree_discipline":"Systems Engineering Management","degree_department":"Systems Engineering (SE)","school":null,"contributors":[],"advisors":["Carlson, Ronald R."],"committee_chairs":[],"committee_members":["Yakimenko, Oleg A."],"year":2018,"date_issued":"2018-09","date_published":"2018-09","updated_at":"2026-11-19T06:38:38Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["28511"],"render_values":[{"text":"28511","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/60348","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/60348","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F60348","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Carlson, Ronald R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yakimenko, Oleg A."]},{"key":"dc:contributor.department","label":"Department","values":["Systems Engineering (SE)"]},{"key":"dc:creator","label":"Author","values":["Solis, Carlos G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-10-26T19:20:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-10-26T19:20:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering Management"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Systems Engineering Management"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["28511"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["International Electro Technical Commission","military standards","electromagnetic compatibility","electromagnetic interference","Electromagnetic Environmental Effects","E3","radiated susceptibility","immunity","dwell time","field strength","modulation","frequency"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/60348"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The war on terrorism has been a major driving factor for warfighter use of commercial off-the-shelf (COTS) items. Multiple COTS products have been introduced in the field that have been tested to industry standards, immunity testing, rather than to Department of Defense (DoD) military standards—a subset for Electromagnetic Environmental Effects (E3) testing called Radiated Susceptibility (RS) 103 testing, and External Radio Frequency Electromagnetic Environment (External RF EME) testing. The DoD needs to determine the minimum acceptable test for radiated susceptibility (RS)/Immunity in order to determine the risk, if any, to the operators using these products in the field. Many of the COTS products that have been introduced for DoD use were purportedly assessed to a military specification while being tested to an industry test. This thesis assesses the difference between DoD and industry RS/Immunity testing to determine the worst-case test scenario for ground systems."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["SVAD"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/assessmentonradi1094560348"]},{"key":"dc:title","label":"Title","values":["ASSESSMENT ON RADIATED SUSCEPTIBILITY TESTING WITHIN THE DOD AND INDUSTRY"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Civilian, Department of the Air Force"]}]}],"canonical_facts":{"dc:contributor.advisor":["Carlson, Ronald R."],"dc:contributor.committeemember":["Yakimenko, Oleg A."],"dc:contributor.department":["Systems Engineering (SE)"],"dc:creator":["Solis, Carlos G."],"dc:date.accessioned":["2018-10-26T19:20:39Z"],"dc:date.available":["2018-10-26T19:20:39Z"],"dc:date.issued":["2018-09"],"dc:description.abstract":["The war on terrorism has been a major driving factor for warfighter use of commercial off-the-shelf (COTS) items. Multiple COTS products have been introduced in the field that have been tested to industry standards, immunity testing, rather than to Department of Defense (DoD) military standards—a subset for Electromagnetic Environmental Effects (E3) testing called Radiated Susceptibility (RS) 103 testing, and External Radio Frequency Electromagnetic Environment (External RF EME) testing. The DoD needs to determine the minimum acceptable test for radiated susceptibility (RS)/Immunity in order to determine the risk, if any, to the operators using these products in the field. Many of the COTS products that have been introduced for DoD use were purportedly assessed to a military specification while being tested to an industry test. This thesis assesses the difference between DoD and industry RS/Immunity testing to determine the worst-case test scenario for ground systems."],"dc:description.sponsorship":["SVAD"],"dc:description.uri":["http://archive.org/details/assessmentonradi1094560348"],"dc:identifier.uri":["https://hdl.handle.net/10945/60348"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["International Electro Technical Commission","military standards","electromagnetic compatibility","electromagnetic interference","Electromagnetic Environmental Effects","E3","radiated susceptibility","immunity","dwell time","field strength","modulation","frequency"],"dc:title":["ASSESSMENT ON RADIATED SUSCEPTIBILITY TESTING WITHIN THE DOD AND INDUSTRY"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Civilian, Department of the Air Force"],"thesis:degree_discipline":["Systems Engineering Management"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Systems Engineering Management"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["28511"]},"updated_at":"2026-11-19T06:38:38Z"}