{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/6123"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/6123","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Testing and performance characterization of the split field polarimeter in the 3-5 um waveband","abstract":"The infrared (IR) radiation emitted or reflected in an off-normal direction from a smooth surface is partially polarized. This principle can be used for enhanced discrimination of targets from backgrounds in marine environment. It has been shown that (man-made) targets do not demonstrate a pronounced polarization effect when observed at near normal exitance whereas the sea background radiation has a significant degree of polarization in slant observation directions. The NPS split-field polarimeter was previously designed and constructed to provide simultaneous image pairs in a single frame, differing only in the direction of linear polarization. The system can operate in both long wavelength (8-12 Ã¦m) and the mid wavelength (3-5 Ã¦m) with interchangeable polarizing splitter plates. In this thesis, tests were conducted to visually compare the polarizing effect on objects in the 3-5 Ã¦m waveband using the polarimeter and with the external polarizer. The image recorded in the laboratory with the horizontal and vertical polarizations depicts a contrast enhancement differing with varied aspect of the target. With the successful demonstration of the polarimeter operability, the performance of the thermal imager operated with and without the polarimeter was characterized by measuring its Minimum Resolvable Temperature Difference (MRTD) as a function of different spatial frequency. The measured performance was then compared against the same thermal imager using an external polarizer. The measured MRTD curve is used to model the system detection and recognition range using the Johnson criteria.","abstract_html":"The infrared (IR) radiation emitted or reflected in an off-normal direction from a smooth surface is partially polarized. This principle can be used for enhanced discrimination of targets from backgrounds in marine environment. It has been shown that (man-made) targets do not demonstrate a pronounced polarization effect when observed at near normal exitance whereas the sea background radiation has a significant degree of polarization in slant observation directions. The NPS split-field polarimeter was previously designed and constructed to provide simultaneous image pairs in a single frame, differing only in the direction of linear polarization. The system can operate in both long wavelength (8-12 Ã¦m) and the mid wavelength (3-5 Ã¦m) with interchangeable polarizing splitter plates. In this thesis, tests were conducted to visually compare the polarizing effect on objects in the 3-5 Ã¦m waveband using the polarimeter and with the external polarizer. The image recorded in the laboratory with the horizontal and vertical polarizations depicts a contrast enhancement differing with varied aspect of the target. With the successful demonstration of the polarimeter operability, the performance of the thermal imager operated with and without the polarimeter was characterized by measuring its Minimum Resolvable Temperature Difference (MRTD) as a function of different spatial frequency. The measured performance was then compared against the same thermal imager using an external polarizer. The measured MRTD curve is used to model the system detection and recognition range using the Johnson criteria.","abstract_has_math":false,"creators":["Tung, Yan Foo"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Combat Systems Technology","degree_level":"Masters","degree_discipline":"Combat Systems Technology","degree_department":"Physics","school":null,"contributors":[],"advisors":["Cooper, Alfred W.","Karunasiri, Gamani"],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-12","date_published":"2003-12","updated_at":"2026-11-19T06:38:50Z","subjects":["Infrared radiation","Military applications","Polariscope","Polarization (Light)"],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/6123","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/6123","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F6123","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F6123","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cooper, Alfred W.","Karunasiri, Gamani"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Tung, Yan Foo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 2003"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:47:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:47:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2003-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Combat Systems Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Combat Systems Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Thermal imaging","Polarization","Infrared radiation","Split field polarimeter"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Infrared radiation","Military applications","Polariscope","Polarization (Light)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/6123"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The infrared (IR) radiation emitted or reflected in an off-normal direction from a smooth surface is partially polarized. This principle can be used for enhanced discrimination of targets from backgrounds in marine environment. It has been shown that (man-made) targets do not demonstrate a pronounced polarization effect when observed at near normal exitance whereas the sea background radiation has a significant degree of polarization in slant observation directions. The NPS split-field polarimeter was previously designed and constructed to provide simultaneous image pairs in a single frame, differing only in the direction of linear polarization. The system can operate in both long wavelength (8-12 Ã¦m) and the mid wavelength (3-5 Ã¦m) with interchangeable polarizing splitter plates. In this thesis, tests were conducted to visually compare the polarizing effect on objects in the 3-5 Ã¦m waveband using the polarimeter and with the external polarizer. The image recorded in the laboratory with the horizontal and vertical polarizations depicts a contrast enhancement differing with varied aspect of the target. With the successful demonstration of the polarimeter operability, the performance of the thermal imager operated with and without the polarimeter was characterized by measuring its Minimum Resolvable Temperature Difference (MRTD) as a function of different spatial frequency. The measured performance was then compared against the same thermal imager using an external polarizer. The measured MRTD curve is used to model the system detection and recognition range using the Johnson criteria."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/testingndperform109456123"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 85 p. : ill. (some col.)"]},{"key":"dc:title","label":"Title","values":["Testing and performance characterization of the split field polarimeter in the 3-5 um waveband"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Civilian, Defence Science and Technology Agency, Singapore"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cooper, Alfred W.","Karunasiri, Gamani"],"dc:contributor.department":["Physics"],"dc:creator":["Tung, Yan Foo"],"dc:date":["December 2003"],"dc:date.accessioned":["2012-03-14T17:47:50Z"],"dc:date.available":["2012-03-14T17:47:50Z"],"dc:date.issued":["2003-12"],"dc:description.abstract":["The infrared (IR) radiation emitted or reflected in an off-normal direction from a smooth surface is partially polarized. This principle can be used for enhanced discrimination of targets from backgrounds in marine environment. It has been shown that (man-made) targets do not demonstrate a pronounced polarization effect when observed at near normal exitance whereas the sea background radiation has a significant degree of polarization in slant observation directions. The NPS split-field polarimeter was previously designed and constructed to provide simultaneous image pairs in a single frame, differing only in the direction of linear polarization. The system can operate in both long wavelength (8-12 Ã¦m) and the mid wavelength (3-5 Ã¦m) with interchangeable polarizing splitter plates. In this thesis, tests were conducted to visually compare the polarizing effect on objects in the 3-5 Ã¦m waveband using the polarimeter and with the external polarizer. The image recorded in the laboratory with the horizontal and vertical polarizations depicts a contrast enhancement differing with varied aspect of the target. With the successful demonstration of the polarimeter operability, the performance of the thermal imager operated with and without the polarimeter was characterized by measuring its Minimum Resolvable Temperature Difference (MRTD) as a function of different spatial frequency. The measured performance was then compared against the same thermal imager using an external polarizer. The measured MRTD curve is used to model the system detection and recognition range using the Johnson criteria."],"dc:description.uri":["http://archive.org/details/testingndperform109456123"],"dc:format.extent":["xiv, 85 p. : ill. (some col.)"],"dc:identifier.uri":["https://hdl.handle.net/10945/6123"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Thermal imaging","Polarization","Infrared radiation","Split field polarimeter"],"dc:subject.lcsh":["Infrared radiation","Military applications","Polariscope","Polarization (Light)"],"dc:title":["Testing and performance characterization of the split field polarimeter in the 3-5 um waveband"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Civilian, Defence Science and Technology Agency, Singapore"],"local:etd.verified":["no"],"thesis:degree_discipline":["Combat Systems Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Combat Systems Technology"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:38:50Z"}