{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/6177"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/6177","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Investigation of outer length scale in optical turbulence","abstract":"100 prevailed. The primary reason was that inadequate sampling of the turbulent layers prevented the computation of valid statistical averages. The volume backscatter cross-section measured by an acoustic sounder provided better statistical averaging of the optical structure parameter C than the microthermal balloon data. The separation of daytime convective thermal plumes was found from the acoustic sounder data by computing average C values between 20 to 50 meters for each acoustic pulse and performing an autocorrelation of these averages over 600 seconds. Multiplying the autocorrelation time by the wind speed gave the separation between the convective thermal maxima and their minima. The mean correlation length for March 2002 at the Starfire Optical Range was 1590 hlmghl2n2nÅ 770 meters, between 1000 and 1600 local time. This length is proportional to the convective thermal cell size and to the boundary layer inversion height. A smaller length scale of 200 meters also appeared in the acoustic sounder data associated with the local height of the data and the hill above the ground.","abstract_html":"100 prevailed. The primary reason was that inadequate sampling of the turbulent layers prevented the computation of valid statistical averages. The volume backscatter cross-section measured by an acoustic sounder provided better statistical averaging of the optical structure parameter C than the microthermal balloon data. The separation of daytime convective thermal plumes was found from the acoustic sounder data by computing average C values between 20 to 50 meters for each acoustic pulse and performing an autocorrelation of these averages over 600 seconds. Multiplying the autocorrelation time by the wind speed gave the separation between the convective thermal maxima and their minima. The mean correlation length for March 2002 at the Starfire Optical Range was 1590 hlmghl2n2nÅ 770 meters, between 1000 and 1600 local time. This length is proportional to the convective thermal cell size and to the boundary layer inversion height. A smaller length scale of 200 meters also appeared in the acoustic sounder data associated with the local height of the data and the hill above the ground.","abstract_has_math":false,"creators":["Lim, Steven S.M."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Combat Systems Technology","degree_level":"Masters","degree_discipline":"Combat Systems Technology","degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":["Walters, D.L.","Miller, D.K."],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-12","date_published":"2003-12","updated_at":"2026-11-19T06:38:50Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/6177","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/6177","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F6177","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F6177","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Walters, D.L.","Miller, D.K."]},{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Lim, Steven S.M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:48:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:48:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2003-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Combat Systems Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Combat Systems Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Atmospheric Structure Parameter","Atmospheric turbulence","Outer Length Scale","Richardson Number","Acoustic Sounder","Thermosonde","Optical turbulence"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/6177"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["100 prevailed. The primary reason was that inadequate sampling of the turbulent layers prevented the computation of valid statistical averages. The volume backscatter cross-section measured by an acoustic sounder provided better statistical averaging of the optical structure parameter C than the microthermal balloon data. The separation of daytime convective thermal plumes was found from the acoustic sounder data by computing average C values between 20 to 50 meters for each acoustic pulse and performing an autocorrelation of these averages over 600 seconds. Multiplying the autocorrelation time by the wind speed gave the separation between the convective thermal maxima and their minima. The mean correlation length for March 2002 at the Starfire Optical Range was 1590 hlmghl2n2nÅ 770 meters, between 1000 and 1600 local time. This length is proportional to the convective thermal cell size and to the boundary layer inversion height. A smaller length scale of 200 meters also appeared in the acoustic sounder data associated with the local height of the data and the hill above the ground."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/investigationofo109456177"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 37 p. : col. ill. ;"]},{"key":"dc:title","label":"Title","values":["Investigation of outer length scale in optical turbulence"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, Republic of Singapore Army"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Walters, D.L.","Miller, D.K."],"dc:contributor.department":["Physics (PH)"],"dc:creator":["Lim, Steven S.M."],"dc:date.accessioned":["2012-03-14T17:48:00Z"],"dc:date.available":["2012-03-14T17:48:00Z"],"dc:date.issued":["2003-12"],"dc:description.abstract":["100 prevailed. The primary reason was that inadequate sampling of the turbulent layers prevented the computation of valid statistical averages. The volume backscatter cross-section measured by an acoustic sounder provided better statistical averaging of the optical structure parameter C than the microthermal balloon data. The separation of daytime convective thermal plumes was found from the acoustic sounder data by computing average C values between 20 to 50 meters for each acoustic pulse and performing an autocorrelation of these averages over 600 seconds. Multiplying the autocorrelation time by the wind speed gave the separation between the convective thermal maxima and their minima. The mean correlation length for March 2002 at the Starfire Optical Range was 1590 hlmghl2n2nÅ 770 meters, between 1000 and 1600 local time. This length is proportional to the convective thermal cell size and to the boundary layer inversion height. A smaller length scale of 200 meters also appeared in the acoustic sounder data associated with the local height of the data and the hill above the ground."],"dc:description.uri":["http://archive.org/details/investigationofo109456177"],"dc:format.extent":["xiv, 37 p. : col. ill. ;"],"dc:identifier.uri":["https://hdl.handle.net/10945/6177"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Atmospheric Structure Parameter","Atmospheric turbulence","Outer Length Scale","Richardson Number","Acoustic Sounder","Thermosonde","Optical turbulence"],"dc:title":["Investigation of outer length scale in optical turbulence"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, Republic of Singapore Army"],"local:etd.verified":["no"],"thesis:degree_discipline":["Combat Systems Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Combat Systems Technology"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:38:50Z"}