{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/62752"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/62752","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"ENERGY MANAGEMENT IN NAVAL FACILITIES USING PHASE CHANGE MATERIALS","abstract":"Phase change materials (PCM) offer a great potential to passively cool buildings by using latent heat to store the room thermal energy throughout the day and releasing it at night when the ambient air is cooler. This study supports the ONR Energy, Science and Technology Evaluation Program (ESTEP) by evaluating commercial PCMs and other alternatives to traditional air conditioning methods. Flat panels of PCMs—energy panels—were installed in the ceiling and as a wall in a room. The air temperature in the room was continuously monitored for weeks by imposing varying heat loads to document the effectiveness of the PCM in achieving the desired benefits. The results showed that the PCM reacted very quickly to the applied heat load with a charge time of a few minutes, but still satisfactorily cooled the room. However, a more gradual heat loading permitted the room temperature to remain stable near the PCM melting temperature, which was the goal of the project. These conclusions also enable estimating the PCM mass required for any room if the heat loads can be quantitatively assessed. The results of this study were verified with the DoE energy management software EnergyPlus, a program that uses finite differencing methods to simulate the thermal profile of whole buildings. Reasonable qualitative agreement was obtained between the measurements and calculations.","abstract_html":"Phase change materials (PCM) offer a great potential to passively cool buildings by using latent heat to store the room thermal energy throughout the day and releasing it at night when the ambient air is cooler. This study supports the ONR Energy, Science and Technology Evaluation Program (ESTEP) by evaluating commercial PCMs and other alternatives to traditional air conditioning methods. Flat panels of PCMs—energy panels—were installed in the ceiling and as a wall in a room. The air temperature in the room was continuously monitored for weeks by imposing varying heat loads to document the effectiveness of the PCM in achieving the desired benefits. The results showed that the PCM reacted very quickly to the applied heat load with a charge time of a few minutes, but still satisfactorily cooled the room. However, a more gradual heat loading permitted the room temperature to remain stable near the PCM melting temperature, which was the goal of the project. These conclusions also enable estimating the PCM mass required for any room if the heat loads can be quantitatively assessed. The results of this study were verified with the DoE energy management software EnergyPlus, a program that uses finite differencing methods to simulate the thermal profile of whole buildings. Reasonable qualitative agreement was obtained between the measurements and calculations.","abstract_has_math":false,"creators":["Martinez, Julian M."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical and Aerospace Engineering (MAE)","school":null,"contributors":[],"advisors":["Chandrasekhara, Muguru"],"committee_chairs":[],"committee_members":["Gannon, Anthony J."],"year":2019,"date_issued":"2019-06","date_published":"2019-06","updated_at":"2026-11-19T06:39:09Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["32422"],"render_values":[{"text":"32422","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/62752","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/62752","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F62752","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F62752","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chandrasekhara, Muguru"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gannon, Anthony J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical and Aerospace Engineering (MAE)"]},{"key":"dc:creator","label":"Author","values":["Martinez, Julian M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-08T23:49:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-08T23:49:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["32422"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["phase change material","thermal energy storage","EnergyPlus","BioPCM","passive cooling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/62752"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Phase change materials (PCM) offer a great potential to passively cool buildings by using latent heat to store the room thermal energy throughout the day and releasing it at night when the ambient air is cooler. This study supports the ONR Energy, Science and Technology Evaluation Program (ESTEP) by evaluating commercial PCMs and other alternatives to traditional air conditioning methods. Flat panels of PCMs—energy panels—were installed in the ceiling and as a wall in a room. The air temperature in the room was continuously monitored for weeks by imposing varying heat loads to document the effectiveness of the PCM in achieving the desired benefits. The results showed that the PCM reacted very quickly to the applied heat load with a charge time of a few minutes, but still satisfactorily cooled the room. However, a more gradual heat loading permitted the room temperature to remain stable near the PCM melting temperature, which was the goal of the project. These conclusions also enable estimating the PCM mass required for any room if the heat loads can be quantitatively assessed. The results of this study were verified with the DoE energy management software EnergyPlus, a program that uses finite differencing methods to simulate the thermal profile of whole buildings. Reasonable qualitative agreement was obtained between the measurements and calculations."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["ONR"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/energymanagement1094562752"]},{"key":"dc:title","label":"Title","values":["ENERGY MANAGEMENT IN NAVAL FACILITIES USING PHASE CHANGE MATERIALS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Ensign, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chandrasekhara, Muguru"],"dc:contributor.committeemember":["Gannon, Anthony J."],"dc:contributor.department":["Mechanical and Aerospace Engineering (MAE)"],"dc:creator":["Martinez, Julian M."],"dc:date.accessioned":["2019-08-08T23:49:07Z"],"dc:date.available":["2019-08-08T23:49:07Z"],"dc:date.issued":["2019-06"],"dc:description.abstract":["Phase change materials (PCM) offer a great potential to passively cool buildings by using latent heat to store the room thermal energy throughout the day and releasing it at night when the ambient air is cooler. This study supports the ONR Energy, Science and Technology Evaluation Program (ESTEP) by evaluating commercial PCMs and other alternatives to traditional air conditioning methods. Flat panels of PCMs—energy panels—were installed in the ceiling and as a wall in a room. The air temperature in the room was continuously monitored for weeks by imposing varying heat loads to document the effectiveness of the PCM in achieving the desired benefits. The results showed that the PCM reacted very quickly to the applied heat load with a charge time of a few minutes, but still satisfactorily cooled the room. However, a more gradual heat loading permitted the room temperature to remain stable near the PCM melting temperature, which was the goal of the project. These conclusions also enable estimating the PCM mass required for any room if the heat loads can be quantitatively assessed. The results of this study were verified with the DoE energy management software EnergyPlus, a program that uses finite differencing methods to simulate the thermal profile of whole buildings. Reasonable qualitative agreement was obtained between the measurements and calculations."],"dc:description.sponsorship":["ONR"],"dc:description.uri":["http://archive.org/details/energymanagement1094562752"],"dc:identifier.uri":["https://hdl.handle.net/10945/62752"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["phase change material","thermal energy storage","EnergyPlus","BioPCM","passive cooling"],"dc:title":["ENERGY MANAGEMENT IN NAVAL FACILITIES USING PHASE CHANGE MATERIALS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Ensign, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["32422"]},"updated_at":"2026-11-19T06:39:09Z"}