{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/62816"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/62816","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"IMPLEMENTATION OF ACTIVE AND REACTIVE POWER FLOW CONTROL IN A SINGLE PHASE MICROGRID","abstract":"A microgrid is a miniature version of a large power grid, and its purpose is to operate autonomously and to increase the reliability of the power system in a naval installation. It is a local area power system, which is able to operate either as a subset of a main grid or in an autonomous mode (islanded). The power flowing from a utility to a microgrid and vice-versa has two components: 1) active power, which is the real power that can be transformed from electric to non-electric by the loads; and 2) reactive power, which is generated by inductive loads, such as electric motors. The presence of the latter category lessens the energy efficiency of an installation, reduces the real energy, and increases the cost of the electricity for the consumer. The compensation for the reactive power and simultaneously the control of the active power is obtained by a highly developed electronic system, called the Energy Management System (EMS). It manages the distributed energy resources in a microgrid, such as batteries, and renewable energy sources to ensure that electricity is available to an installation when the main grid is off. In our research, four different methods of EMS control have been examined in order to regulate the electricity delivered to the consumer for maximum available power and to reduce the cost of the electricity. Simulated plots are presented and validated by experimental waveforms measured on a laboratory prototype.","abstract_html":"A microgrid is a miniature version of a large power grid, and its purpose is to operate autonomously and to increase the reliability of the power system in a naval installation. It is a local area power system, which is able to operate either as a subset of a main grid or in an autonomous mode (islanded). The power flowing from a utility to a microgrid and vice-versa has two components: 1) active power, which is the real power that can be transformed from electric to non-electric by the loads; and 2) reactive power, which is generated by inductive loads, such as electric motors. The presence of the latter category lessens the energy efficiency of an installation, reduces the real energy, and increases the cost of the electricity for the consumer. The compensation for the reactive power and simultaneously the control of the active power is obtained by a highly developed electronic system, called the Energy Management System (EMS). It manages the distributed energy resources in a microgrid, such as batteries, and renewable energy sources to ensure that electricity is available to an installation when the main grid is off. In our research, four different methods of EMS control have been examined in order to regulate the electricity delivered to the consumer for maximum available power and to reduce the cost of the electricity. Simulated plots are presented and validated by experimental waveforms measured on a laboratory prototype.","abstract_has_math":false,"creators":["Kanavaros, Dimitrios"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Cristi, Roberto","Calusdian, James","Julian, Alexander","Oriti, Giovanna"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-06","date_published":"2019-06","updated_at":"2026-11-19T06:39:09Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["31825"],"render_values":[{"text":"31825","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/62816","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/62816","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F62816","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cristi, Roberto","Calusdian, James","Julian, Alexander","Oriti, Giovanna"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Kanavaros, Dimitrios"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-08T23:49:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-08T23:49:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f4822f3e-2aea-40ad-9b4a-288607743ad7"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering","Electrical Engineer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering","Electrical Engineer"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["31825"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["active power","reactive power","power factor","microgrid","single phase microgrid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/62816"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A microgrid is a miniature version of a large power grid, and its purpose is to operate autonomously and to increase the reliability of the power system in a naval installation. It is a local area power system, which is able to operate either as a subset of a main grid or in an autonomous mode (islanded). The power flowing from a utility to a microgrid and vice-versa has two components: 1) active power, which is the real power that can be transformed from electric to non-electric by the loads; and 2) reactive power, which is generated by inductive loads, such as electric motors. The presence of the latter category lessens the energy efficiency of an installation, reduces the real energy, and increases the cost of the electricity for the consumer. The compensation for the reactive power and simultaneously the control of the active power is obtained by a highly developed electronic system, called the Energy Management System (EMS). It manages the distributed energy resources in a microgrid, such as batteries, and renewable energy sources to ensure that electricity is available to an installation when the main grid is off. In our research, four different methods of EMS control have been examined in order to regulate the electricity delivered to the consumer for maximum available power and to reduce the cost of the electricity. Simulated plots are presented and validated by experimental waveforms measured on a laboratory prototype."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/implementationof1094562816"]},{"key":"dc:title","label":"Title","values":["IMPLEMENTATION OF ACTIVE AND REACTIVE POWER FLOW CONTROL IN A SINGLE PHASE MICROGRID"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, Hellenic Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cristi, Roberto","Calusdian, James","Julian, Alexander","Oriti, Giovanna"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Kanavaros, Dimitrios"],"dc:date.accessioned":["2019-08-08T23:49:55Z"],"dc:date.available":["2019-08-08T23:49:55Z"],"dc:date.issued":["2019-06"],"dc:description.abstract":["A microgrid is a miniature version of a large power grid, and its purpose is to operate autonomously and to increase the reliability of the power system in a naval installation. It is a local area power system, which is able to operate either as a subset of a main grid or in an autonomous mode (islanded). The power flowing from a utility to a microgrid and vice-versa has two components: 1) active power, which is the real power that can be transformed from electric to non-electric by the loads; and 2) reactive power, which is generated by inductive loads, such as electric motors. The presence of the latter category lessens the energy efficiency of an installation, reduces the real energy, and increases the cost of the electricity for the consumer. The compensation for the reactive power and simultaneously the control of the active power is obtained by a highly developed electronic system, called the Energy Management System (EMS). It manages the distributed energy resources in a microgrid, such as batteries, and renewable energy sources to ensure that electricity is available to an installation when the main grid is off. In our research, four different methods of EMS control have been examined in order to regulate the electricity delivered to the consumer for maximum available power and to reduce the cost of the electricity. Simulated plots are presented and validated by experimental waveforms measured on a laboratory prototype."],"dc:description.uri":["http://archive.org/details/implementationof1094562816"],"dc:identifier.uri":["https://hdl.handle.net/10945/62816"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["f4822f3e-2aea-40ad-9b4a-288607743ad7"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["active power","reactive power","power factor","microgrid","single phase microgrid"],"dc:title":["IMPLEMENTATION OF ACTIVE AND REACTIVE POWER FLOW CONTROL IN A SINGLE PHASE MICROGRID"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, Hellenic Navy"],"thesis:degree_discipline":["Electrical Engineering","Electrical Engineer"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering","Electrical Engineer"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["31825"]},"updated_at":"2026-11-19T06:39:09Z"}