{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/6284"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/6284","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Experimental determination of paraxial ray transfer matrices and cardinal points of complex optical systems by means of finite conjugate imaging","abstract":"The Lineate Imaging Near-ultraviolet Spectrometer (LINUS) uses three complex lens systems to focus an image from distances on the order of several kilometers onto the image intensifier of an ultraviolet camera. These images can then be analyzed to characterize the atmospheric distribution and concentration of sulfur dioxide (SO2). The lenses purchased for LINUS were corrected for spherical aberrations but due to the lack of detailed knowledge about the lenses their chromatic aberrations could not be readily predicted. The project presented in this thesis was performed with the goal of experimentally quantifying the chromatic aberrations of each of LINUSÎ±s lens systems. The matrix method of representing paraxial optical systems was used to determine relationships between object and image distances for different lens systems. These relationships were manipulated to give equations for the matrix elements of the lens system in terms of readily measurable parameters. Once the matrix elements are known, all of the cardinal points can be readily predicted. This method will, in theory, quantify the chromatic aberrations of each lens system. The method was validated with simulations and measurements taken on a lens of known focal length. Finally, the LINUS lens systems were characterized at 220, 300, 334, and 370 nm.","abstract_html":"The Lineate Imaging Near-ultraviolet Spectrometer (LINUS) uses three complex lens systems to focus an image from distances on the order of several kilometers onto the image intensifier of an ultraviolet camera. These images can then be analyzed to characterize the atmospheric distribution and concentration of sulfur dioxide (SO2). The lenses purchased for LINUS were corrected for spherical aberrations but due to the lack of detailed knowledge about the lenses their chromatic aberrations could not be readily predicted. The project presented in this thesis was performed with the goal of experimentally quantifying the chromatic aberrations of each of LINUSÎ±s lens systems. The matrix method of representing paraxial optical systems was used to determine relationships between object and image distances for different lens systems. These relationships were manipulated to give equations for the matrix elements of the lens system in terms of readily measurable parameters. Once the matrix elements are known, all of the cardinal points can be readily predicted. This method will, in theory, quantify the chromatic aberrations of each lens system. The method was validated with simulations and measurements taken on a lens of known focal length. Finally, the LINUS lens systems were characterized at 220, 300, 334, and 370 nm.","abstract_has_math":false,"creators":["Blackwell, Jerry S."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":["Davis, D. Scott"],"committee_chairs":[],"committee_members":["Harkins, Richard"],"year":2001,"date_issued":"2001-12","date_published":"2001-12","updated_at":"2026-11-19T06:39:09Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["266943"],"render_values":[{"text":"266943","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/6284","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/6284","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F6284","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Davis, D. Scott"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Harkins, Richard"]},{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Blackwell, Jerry S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:48:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:48:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2001-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["ultraviolet spectroscopy","matrix method","complex lens systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["266943"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/6284"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Lineate Imaging Near-ultraviolet Spectrometer (LINUS) uses three complex lens systems to focus an image from distances on the order of several kilometers onto the image intensifier of an ultraviolet camera. These images can then be analyzed to characterize the atmospheric distribution and concentration of sulfur dioxide (SO2). The lenses purchased for LINUS were corrected for spherical aberrations but due to the lack of detailed knowledge about the lenses their chromatic aberrations could not be readily predicted. The project presented in this thesis was performed with the goal of experimentally quantifying the chromatic aberrations of each of LINUSÎ±s lens systems. The matrix method of representing paraxial optical systems was used to determine relationships between object and image distances for different lens systems. These relationships were manipulated to give equations for the matrix elements of the lens system in terms of readily measurable parameters. Once the matrix elements are known, all of the cardinal points can be readily predicted. This method will, in theory, quantify the chromatic aberrations of each lens system. The method was validated with simulations and measurements taken on a lens of known focal length. Finally, the LINUS lens systems were characterized at 220, 300, 334, and 370 nm."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/experimentaldete109456284"]},{"key":"dc:title","label":"Title","values":["Experimental determination of paraxial ray transfer matrices and cardinal points of complex optical systems by means of finite conjugate imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Davis, D. Scott"],"dc:contributor.committeemember":["Harkins, Richard"],"dc:contributor.department":["Physics (PH)"],"dc:creator":["Blackwell, Jerry S."],"dc:date.accessioned":["2012-03-14T17:48:22Z"],"dc:date.available":["2012-03-14T17:48:22Z"],"dc:date.issued":["2001-12"],"dc:description.abstract":["The Lineate Imaging Near-ultraviolet Spectrometer (LINUS) uses three complex lens systems to focus an image from distances on the order of several kilometers onto the image intensifier of an ultraviolet camera. These images can then be analyzed to characterize the atmospheric distribution and concentration of sulfur dioxide (SO2). The lenses purchased for LINUS were corrected for spherical aberrations but due to the lack of detailed knowledge about the lenses their chromatic aberrations could not be readily predicted. The project presented in this thesis was performed with the goal of experimentally quantifying the chromatic aberrations of each of LINUSÎ±s lens systems. The matrix method of representing paraxial optical systems was used to determine relationships between object and image distances for different lens systems. These relationships were manipulated to give equations for the matrix elements of the lens system in terms of readily measurable parameters. Once the matrix elements are known, all of the cardinal points can be readily predicted. This method will, in theory, quantify the chromatic aberrations of each lens system. The method was validated with simulations and measurements taken on a lens of known focal length. Finally, the LINUS lens systems were characterized at 220, 300, 334, and 370 nm."],"dc:description.uri":["http://archive.org/details/experimentaldete109456284"],"dc:identifier.oclc":["266943"],"dc:identifier.uri":["https://hdl.handle.net/10945/6284"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["ultraviolet spectroscopy","matrix method","complex lens systems"],"dc:title":["Experimental determination of paraxial ray transfer matrices and cardinal points of complex optical systems by means of finite conjugate imaging"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:39:09Z"}