{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/64181"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/64181","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"OBSERVABILITY ANALYSIS FOR THE DETECTION AND ESTIMATION OF MICROGRID ACTIVITIES","abstract":"This research investigates the suitability of employing the observability Gramian as a computational instrument in analyzing microgrid system operations. An observable system permits the use of a limited sensor network to provide fault detection, abnormal activity detection, and system calibration with partial information. Microgrids can be modeled using systems of ordinary differential equations (ODEs). The observability Gramian is calculated using the solution to the ODEs with perturbed initial conditions. The observability is determined by the minimum eigenvalue of the Gramian matrix. A large minimum eigenvalue implies that the system is strongly observable, while a small value means the system is weakly observable or practically unobservable. Employing contactless sensors allows a non-invasive method of monitoring the system without interruption. As a case study, the empirical observability Gramian was numerically computed using a 9-bus microgrid model solving a system of nonlinear ODEs with 6 state variables and 12 parameters. The case study first determines the observability of various sensor network configurations, and then an observability analysis for fault detection introduces variations in system parameters. This case study showed that, depending on the sensor network configuration, microgrids can be observable in the presence of unknown parameter variation.","abstract_html":"This research investigates the suitability of employing the observability Gramian as a computational instrument in analyzing microgrid system operations. An observable system permits the use of a limited sensor network to provide fault detection, abnormal activity detection, and system calibration with partial information. Microgrids can be modeled using systems of ordinary differential equations (ODEs). The observability Gramian is calculated using the solution to the ODEs with perturbed initial conditions. The observability is determined by the minimum eigenvalue of the Gramian matrix. A large minimum eigenvalue implies that the system is strongly observable, while a small value means the system is weakly observable or practically unobservable. Employing contactless sensors allows a non-invasive method of monitoring the system without interruption. As a case study, the empirical observability Gramian was numerically computed using a 9-bus microgrid model solving a system of nonlinear ODEs with 6 state variables and 12 parameters. The case study first determines the observability of various sensor network configurations, and then an observability analysis for fault detection introduces variations in system parameters. This case study showed that, depending on the sensor network configuration, microgrids can be observable in the presence of unknown parameter variation.","abstract_has_math":false,"creators":["Andriulli, Mario C."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Applied Mathematics","degree_level":"Masters","degree_discipline":"Applied Mathematics","degree_department":"Applied Mathematics (MA)","school":null,"contributors":[],"advisors":["Kang, Wei"],"committee_chairs":[],"committee_members":["Krener, Arthur J."],"year":2019,"date_issued":"2019-12","date_published":"2019-12","updated_at":"2026-11-19T06:39:25Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["32883"],"render_values":[{"text":"32883","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/64181","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/64181","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F64181","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F64181","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kang, Wei"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Krener, Arthur J."]},{"key":"dc:contributor.department","label":"Department","values":["Applied Mathematics (MA)"]},{"key":"dc:creator","label":"Author","values":["Andriulli, Mario C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-02-20T01:32:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-02-20T01:32:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Mathematics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Mathematics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["32883"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["observability","controllability","Gramian","microgrid","electricity","ordinary differential equation","MATLAB"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/64181"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research investigates the suitability of employing the observability Gramian as a computational instrument in analyzing microgrid system operations. An observable system permits the use of a limited sensor network to provide fault detection, abnormal activity detection, and system calibration with partial information. Microgrids can be modeled using systems of ordinary differential equations (ODEs). The observability Gramian is calculated using the solution to the ODEs with perturbed initial conditions. The observability is determined by the minimum eigenvalue of the Gramian matrix. A large minimum eigenvalue implies that the system is strongly observable, while a small value means the system is weakly observable or practically unobservable. Employing contactless sensors allows a non-invasive method of monitoring the system without interruption. As a case study, the empirical observability Gramian was numerically computed using a 9-bus microgrid model solving a system of nonlinear ODEs with 6 state variables and 12 parameters. The case study first determines the observability of various sensor network configurations, and then an observability analysis for fault detection introduces variations in system parameters. This case study showed that, depending on the sensor network configuration, microgrids can be observable in the presence of unknown parameter variation."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/observabilityana1094564181"]},{"key":"dc:title","label":"Title","values":["OBSERVABILITY ANALYSIS FOR THE DETECTION AND ESTIMATION OF MICROGRID ACTIVITIES"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kang, Wei"],"dc:contributor.committeemember":["Krener, Arthur J."],"dc:contributor.department":["Applied Mathematics (MA)"],"dc:creator":["Andriulli, Mario C."],"dc:date.accessioned":["2020-02-20T01:32:29Z"],"dc:date.available":["2020-02-20T01:32:29Z"],"dc:date.issued":["2019-12"],"dc:description.abstract":["This research investigates the suitability of employing the observability Gramian as a computational instrument in analyzing microgrid system operations. An observable system permits the use of a limited sensor network to provide fault detection, abnormal activity detection, and system calibration with partial information. Microgrids can be modeled using systems of ordinary differential equations (ODEs). The observability Gramian is calculated using the solution to the ODEs with perturbed initial conditions. The observability is determined by the minimum eigenvalue of the Gramian matrix. A large minimum eigenvalue implies that the system is strongly observable, while a small value means the system is weakly observable or practically unobservable. Employing contactless sensors allows a non-invasive method of monitoring the system without interruption. As a case study, the empirical observability Gramian was numerically computed using a 9-bus microgrid model solving a system of nonlinear ODEs with 6 state variables and 12 parameters. The case study first determines the observability of various sensor network configurations, and then an observability analysis for fault detection introduces variations in system parameters. This case study showed that, depending on the sensor network configuration, microgrids can be observable in the presence of unknown parameter variation."],"dc:description.uri":["http://archive.org/details/observabilityana1094564181"],"dc:identifier.uri":["https://hdl.handle.net/10945/64181"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["observability","controllability","Gramian","microgrid","electricity","ordinary differential equation","MATLAB"],"dc:title":["OBSERVABILITY ANALYSIS FOR THE DETECTION AND ESTIMATION OF MICROGRID ACTIVITIES"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Army"],"thesis:degree_discipline":["Applied Mathematics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Applied Mathematics"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["32883"]},"updated_at":"2026-11-19T06:39:25Z"}