{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/64887"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/64887","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"EVALUATION OF UNSCHEDULED INTENTIONAL ISLANDING METHODS FOR SINGLE PHASE GRID-CONNECTED INVERTERS IN COMPLIANCE WITH IEEE STANDARD 1547-2018","abstract":"A power electronics-based Energy Management System (EMS) is a key component of a microgrid; it manages loads, controls power flow to improve overall efficiency, and disconnects Distributed Energy Resources (DER) from the main grid in the event of a grid fault. The latter is the focus of the research conducted in this thesis. IEEE Standard 1547-2018 provides the requirements relevant to the connection of a microgrid to the main grid. The standard requires that the disconnection control method maintains connection for a specified time, known as voltage ride-through time, during voltage disturbances in the main grid voltage. This thesis explores five different methods of EMS control and their respective algorithm for disconnection from the grid. The response times of disconnection from the grid are simulated using a physics-based model validated by experimental measurements on a laboratory prototype. The simulations are compared against the IEEE Standard 1547-2018 voltage ride-through times to determine if the different controller dynamic responses meet the requirements. Of the five methods tested, all were in compliance with IEEE Standard 1547-2018 grid disconnection times but only the two best performing methods, extended Multiple Second Order Generalized Integrator (MSOGI) and true root mean squared (RMS), were able to comply with the voltage ride-through requirements.","abstract_html":"A power electronics-based Energy Management System (EMS) is a key component of a microgrid; it manages loads, controls power flow to improve overall efficiency, and disconnects Distributed Energy Resources (DER) from the main grid in the event of a grid fault. The latter is the focus of the research conducted in this thesis. IEEE Standard 1547-2018 provides the requirements relevant to the connection of a microgrid to the main grid. The standard requires that the disconnection control method maintains connection for a specified time, known as voltage ride-through time, during voltage disturbances in the main grid voltage. This thesis explores five different methods of EMS control and their respective algorithm for disconnection from the grid. The response times of disconnection from the grid are simulated using a physics-based model validated by experimental measurements on a laboratory prototype. The simulations are compared against the IEEE Standard 1547-2018 voltage ride-through times to determine if the different controller dynamic responses meet the requirements. Of the five methods tested, all were in compliance with IEEE Standard 1547-2018 grid disconnection times but only the two best performing methods, extended Multiple Second Order Generalized Integrator (MSOGI) and true root mean squared (RMS), were able to comply with the voltage ride-through requirements.","abstract_has_math":false,"creators":["Tencate, Timothy"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Cristi, Roberto","Oriti, Giovanna"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-03","date_published":"2020-03","updated_at":"2026-11-19T06:39:25Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["32710"],"render_values":[{"text":"32710","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/64887","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/64887","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F64887","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F64887","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cristi, Roberto","Oriti, Giovanna"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Tencate, Timothy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-06-05T17:16:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-06-05T17:16:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f4822f3e-2aea-40ad-9b4a-288607743ad7"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["32710"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["microgrid","supercapacitors","IEEE Standard 1547","Distributed Energy Resources"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/64887"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A power electronics-based Energy Management System (EMS) is a key component of a microgrid; it manages loads, controls power flow to improve overall efficiency, and disconnects Distributed Energy Resources (DER) from the main grid in the event of a grid fault. The latter is the focus of the research conducted in this thesis. IEEE Standard 1547-2018 provides the requirements relevant to the connection of a microgrid to the main grid. The standard requires that the disconnection control method maintains connection for a specified time, known as voltage ride-through time, during voltage disturbances in the main grid voltage. This thesis explores five different methods of EMS control and their respective algorithm for disconnection from the grid. The response times of disconnection from the grid are simulated using a physics-based model validated by experimental measurements on a laboratory prototype. The simulations are compared against the IEEE Standard 1547-2018 voltage ride-through times to determine if the different controller dynamic responses meet the requirements. Of the five methods tested, all were in compliance with IEEE Standard 1547-2018 grid disconnection times but only the two best performing methods, extended Multiple Second Order Generalized Integrator (MSOGI) and true root mean squared (RMS), were able to comply with the voltage ride-through requirements."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/evaluationofunsc1094564887"]},{"key":"dc:title","label":"Title","values":["EVALUATION OF UNSCHEDULED INTENTIONAL ISLANDING METHODS FOR SINGLE PHASE GRID-CONNECTED INVERTERS IN COMPLIANCE WITH IEEE STANDARD 1547-2018"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cristi, Roberto","Oriti, Giovanna"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Tencate, Timothy"],"dc:date.accessioned":["2020-06-05T17:16:50Z"],"dc:date.available":["2020-06-05T17:16:50Z"],"dc:date.issued":["2020-03"],"dc:description.abstract":["A power electronics-based Energy Management System (EMS) is a key component of a microgrid; it manages loads, controls power flow to improve overall efficiency, and disconnects Distributed Energy Resources (DER) from the main grid in the event of a grid fault. The latter is the focus of the research conducted in this thesis. IEEE Standard 1547-2018 provides the requirements relevant to the connection of a microgrid to the main grid. The standard requires that the disconnection control method maintains connection for a specified time, known as voltage ride-through time, during voltage disturbances in the main grid voltage. This thesis explores five different methods of EMS control and their respective algorithm for disconnection from the grid. The response times of disconnection from the grid are simulated using a physics-based model validated by experimental measurements on a laboratory prototype. The simulations are compared against the IEEE Standard 1547-2018 voltage ride-through times to determine if the different controller dynamic responses meet the requirements. Of the five methods tested, all were in compliance with IEEE Standard 1547-2018 grid disconnection times but only the two best performing methods, extended Multiple Second Order Generalized Integrator (MSOGI) and true root mean squared (RMS), were able to comply with the voltage ride-through requirements."],"dc:description.uri":["http://archive.org/details/evaluationofunsc1094564887"],"dc:identifier.uri":["https://hdl.handle.net/10945/64887"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["f4822f3e-2aea-40ad-9b4a-288607743ad7"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["microgrid","supercapacitors","IEEE Standard 1547","Distributed Energy Resources"],"dc:title":["EVALUATION OF UNSCHEDULED INTENTIONAL ISLANDING METHODS FOR SINGLE PHASE GRID-CONNECTED INVERTERS IN COMPLIANCE WITH IEEE STANDARD 1547-2018"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["32710"]},"updated_at":"2026-11-19T06:39:25Z"}