{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/66623"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/66623","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"SHIPBOARD VOLTAGE SOURCE INVERTER CONTROL SYSTEM TO MEET MIL-STD-1399-300 LIMITS FOR PULSED POWER LOADS","abstract":"Microgrids are increasingly being adopted throughout the Department of Defense due to their ability to increase energy security. Though each microgrid is unique, one commonality is that each contains loads that could strain the distributed generators on the grid during starting transients. This is especially important in shipboard applications or Marine Corps forward operating bases, where generator droop characteristics could result in unfavorable effects on running machinery during a transient from a newly started load. This thesis research explores a novel controller design for a three-phase voltage source inverter (VSI) that limits the transients on a microgrid while simultaneously correcting the grid power factor to unity. Specifically, transients produced by pulsed power loads as specified in MIL-STD-1399 section 300 are addressed and controlled. The novel controller allows the VSI to use distributed energy resources, such as batteries, renewables, or supercapacitors, to power the initial transient created by large loads. Using stored energy allows the generator to respond to step load changes more slowly while simultaneously reducing the size of the machine required due to reactive power control.","abstract_html":"Microgrids are increasingly being adopted throughout the Department of Defense due to their ability to increase energy security. Though each microgrid is unique, one commonality is that each contains loads that could strain the distributed generators on the grid during starting transients. This is especially important in shipboard applications or Marine Corps forward operating bases, where generator droop characteristics could result in unfavorable effects on running machinery during a transient from a newly started load. This thesis research explores a novel controller design for a three-phase voltage source inverter (VSI) that limits the transients on a microgrid while simultaneously correcting the grid power factor to unity. Specifically, transients produced by pulsed power loads as specified in MIL-STD-1399 section 300 are addressed and controlled. The novel controller allows the VSI to use distributed energy resources, such as batteries, renewables, or supercapacitors, to power the initial transient created by large loads. Using stored energy allows the generator to respond to step load changes more slowly while simultaneously reducing the size of the machine required due to reactive power control.","abstract_has_math":false,"creators":["DeToma, Daniel P."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Julian, Alexander","Oriti, Giovanna","Zhang, Di"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-12","date_published":"2020-12","updated_at":"2026-11-19T06:40:00Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. distribution is unlimited"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"],"render_values":[{"text":"590, Electronic Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["34355"],"render_values":[{"text":"34355","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/66623","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/66623","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F66623","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F66623","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Julian, Alexander","Oriti, Giovanna","Zhang, Di"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["DeToma, Daniel P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-02-23T00:01:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-23T00:01:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f4822f3e-2aea-40ad-9b4a-288607743ad7","e743f4d8-72d2-4b60-b0b8-89c1781ca5b0"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["34355"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["microgrid","peak power shaving","shipboard power","three-phase","active power","power flow","voltage source inverter","grid-connected","pulsed power"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. distribution is unlimited"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/66623"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microgrids are increasingly being adopted throughout the Department of Defense due to their ability to increase energy security. Though each microgrid is unique, one commonality is that each contains loads that could strain the distributed generators on the grid during starting transients. This is especially important in shipboard applications or Marine Corps forward operating bases, where generator droop characteristics could result in unfavorable effects on running machinery during a transient from a newly started load. This thesis research explores a novel controller design for a three-phase voltage source inverter (VSI) that limits the transients on a microgrid while simultaneously correcting the grid power factor to unity. Specifically, transients produced by pulsed power loads as specified in MIL-STD-1399 section 300 are addressed and controlled. The novel controller allows the VSI to use distributed energy resources, such as batteries, renewables, or supercapacitors, to power the initial transient created by large loads. Using stored energy allows the generator to respond to step load changes more slowly while simultaneously reducing the size of the machine required due to reactive power control."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Office of Naval Research"]},{"key":"dc:title","label":"Title","values":["SHIPBOARD VOLTAGE SOURCE INVERTER CONTROL SYSTEM TO MEET MIL-STD-1399-300 LIMITS FOR PULSED POWER LOADS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Julian, Alexander","Oriti, Giovanna","Zhang, Di"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["DeToma, Daniel P."],"dc:date.accessioned":["2021-02-23T00:01:49Z"],"dc:date.available":["2021-02-23T00:01:49Z"],"dc:date.issued":["2020-12"],"dc:description.abstract":["Microgrids are increasingly being adopted throughout the Department of Defense due to their ability to increase energy security. Though each microgrid is unique, one commonality is that each contains loads that could strain the distributed generators on the grid during starting transients. This is especially important in shipboard applications or Marine Corps forward operating bases, where generator droop characteristics could result in unfavorable effects on running machinery during a transient from a newly started load. This thesis research explores a novel controller design for a three-phase voltage source inverter (VSI) that limits the transients on a microgrid while simultaneously correcting the grid power factor to unity. Specifically, transients produced by pulsed power loads as specified in MIL-STD-1399 section 300 are addressed and controlled. The novel controller allows the VSI to use distributed energy resources, such as batteries, renewables, or supercapacitors, to power the initial transient created by large loads. Using stored energy allows the generator to respond to step load changes more slowly while simultaneously reducing the size of the machine required due to reactive power control."],"dc:description.sponsorship":["Office of Naval Research"],"dc:identifier.programcode":["590, Electronic Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/66623"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["f4822f3e-2aea-40ad-9b4a-288607743ad7","e743f4d8-72d2-4b60-b0b8-89c1781ca5b0"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. distribution is unlimited"],"dc:subject.keyword":["microgrid","peak power shaving","shipboard power","three-phase","active power","power flow","voltage source inverter","grid-connected","pulsed power"],"dc:title":["SHIPBOARD VOLTAGE SOURCE INVERTER CONTROL SYSTEM TO MEET MIL-STD-1399-300 LIMITS FOR PULSED POWER LOADS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["34355"]},"updated_at":"2026-11-19T06:40:00Z"}