{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/67761"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/67761","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"IMPLEMENTATION OF AN INDUSTRIAL CONTROL SYSTEM FOR THE GENERATION, COMPRESSION, AND STORAGE OF HYDROGEN FROM RENEWABLE SOURCES","abstract":"This thesis implemented a control system to integrate the generation and compression of hydrogen gas to enable its production from renewable sources at remote locations. To mimic renewable power commercial-off-the-shelf power supplies were used to power the system. For the control system, programmable logic controllers were used to monitor and operate the overall system’s various components. The harvesting of water from the atmosphere, via Peltier dehumidifiers, was found to be intermittent and is the limiting factor for hydrogen yield in the existing system. Hydrogen gas was generated by an electrolyzer at an average mass flow rate of 5.52e-7 kg/s. The membrane dehumidifier installed to dry the saturated hydrogen gas was found to be ineffective. An electrochemical hydrogen compressor was used to compress hydrogen gas to the steady state maximum outlet pressure of 7492 kPa at an average mass flow rate of 4.3773e-10 kg/s. This research demonstrated it is possible to autonomously produce compressed hydrogen gas from renewable sources. Additionally, improvements have been identified for implementation in future system designs.","abstract_html":"This thesis implemented a control system to integrate the generation and compression of hydrogen gas to enable its production from renewable sources at remote locations. To mimic renewable power commercial-off-the-shelf power supplies were used to power the system. For the control system, programmable logic controllers were used to monitor and operate the overall system’s various components. The harvesting of water from the atmosphere, via Peltier dehumidifiers, was found to be intermittent and is the limiting factor for hydrogen yield in the existing system. Hydrogen gas was generated by an electrolyzer at an average mass flow rate of 5.52e-7 kg/s. The membrane dehumidifier installed to dry the saturated hydrogen gas was found to be ineffective. An electrochemical hydrogen compressor was used to compress hydrogen gas to the steady state maximum outlet pressure of 7492 kPa at an average mass flow rate of 4.3773e-10 kg/s. This research demonstrated it is possible to autonomously produce compressed hydrogen gas from renewable sources. Additionally, improvements have been identified for implementation in future system designs.","abstract_has_math":false,"creators":["Lewis, Joshua D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical and Aerospace Engineering (MAE)","school":null,"contributors":[],"advisors":["Gannon, Anthony J.","Smith, Walter"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-06","date_published":"2021-06","updated_at":"2026-11-26T00:03:03Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["570, Naval/Mechanical Engineering"],"render_values":[{"text":"570, Naval/Mechanical Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["34496"],"render_values":[{"text":"34496","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/67761","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/67761","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F67761","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F67761","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gannon, Anthony J.","Smith, Walter"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical and Aerospace Engineering (MAE)"]},{"key":"dc:creator","label":"Author","values":["Lewis, Joshua D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-08-27T01:37:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-08-27T01:37:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["34496"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["hydrogen","hydrogen generation","hydrogen storage","hydrogen compression","EHC compressor","renewable energy","energy security","energy resiliency","PLC","industrial control"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["570, Naval/Mechanical Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/67761"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis implemented a control system to integrate the generation and compression of hydrogen gas to enable its production from renewable sources at remote locations. To mimic renewable power commercial-off-the-shelf power supplies were used to power the system. For the control system, programmable logic controllers were used to monitor and operate the overall system’s various components. The harvesting of water from the atmosphere, via Peltier dehumidifiers, was found to be intermittent and is the limiting factor for hydrogen yield in the existing system. Hydrogen gas was generated by an electrolyzer at an average mass flow rate of 5.52e-7 kg/s. The membrane dehumidifier installed to dry the saturated hydrogen gas was found to be ineffective. An electrochemical hydrogen compressor was used to compress hydrogen gas to the steady state maximum outlet pressure of 7492 kPa at an average mass flow rate of 4.3773e-10 kg/s. This research demonstrated it is possible to autonomously produce compressed hydrogen gas from renewable sources. Additionally, improvements have been identified for implementation in future system designs."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:title","label":"Title","values":["IMPLEMENTATION OF AN INDUSTRIAL CONTROL SYSTEM FOR THE GENERATION, COMPRESSION, AND STORAGE OF HYDROGEN FROM RENEWABLE SOURCES"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gannon, Anthony J.","Smith, Walter"],"dc:contributor.department":["Mechanical and Aerospace Engineering (MAE)"],"dc:creator":["Lewis, Joshua D."],"dc:date.accessioned":["2021-08-27T01:37:36Z"],"dc:date.available":["2021-08-27T01:37:36Z"],"dc:date.issued":["2021-06"],"dc:description.abstract":["This thesis implemented a control system to integrate the generation and compression of hydrogen gas to enable its production from renewable sources at remote locations. To mimic renewable power commercial-off-the-shelf power supplies were used to power the system. For the control system, programmable logic controllers were used to monitor and operate the overall system’s various components. The harvesting of water from the atmosphere, via Peltier dehumidifiers, was found to be intermittent and is the limiting factor for hydrogen yield in the existing system. Hydrogen gas was generated by an electrolyzer at an average mass flow rate of 5.52e-7 kg/s. The membrane dehumidifier installed to dry the saturated hydrogen gas was found to be ineffective. An electrochemical hydrogen compressor was used to compress hydrogen gas to the steady state maximum outlet pressure of 7492 kPa at an average mass flow rate of 4.3773e-10 kg/s. This research demonstrated it is possible to autonomously produce compressed hydrogen gas from renewable sources. Additionally, improvements have been identified for implementation in future system designs."],"dc:description.award":["Outstanding Thesis"],"dc:identifier.programcode":["570, Naval/Mechanical Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/67761"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"dc:subject.keyword":["hydrogen","hydrogen generation","hydrogen storage","hydrogen compression","EHC compressor","renewable energy","energy security","energy resiliency","PLC","industrial control"],"dc:title":["IMPLEMENTATION OF AN INDUSTRIAL CONTROL SYSTEM FOR THE GENERATION, COMPRESSION, AND STORAGE OF HYDROGEN FROM RENEWABLE SOURCES"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["34496"]},"updated_at":"2026-11-26T00:03:03Z"}