{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/70703"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/70703","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"MODELING AND SIMULATIONS FOR OPTIMIZATION OF MICROFLUIDIC MICROCAPACITOR ARRAYS OF BIOMIMETIC ARTIFICIAL MUSCLES FOR QUIET PROPULSION AND EXOSKELETAL LOCOMOTION","abstract":"The technology that we focused on was the biomimetic actuation of microfluidic microcapacitors, which are electrostatically actuated structures that contract and function like biological muscles. Our thesis aims to find the optimal muscle-to-tendon ratio while expanding both the standard and gap design arrays and to find the respective force-density saturation values so predicted force output can be calculated for muscle fibers of a practical size. We also studied if a 3D virtual object can be a suitable model for the human operators’ examination of the artificial muscle and the optimization of its structure. Our results showed a maximum force density saturation of 8800 Pa and 6700 Pa when simulating the standard and gap array respectively with planar polarity wired artificial muscles. The optimal muscle-to-tendon ratio from the data gathered on the standard array simulations is approximately 9 to 1, meaning 90 percent of the surface area of the XY plane represents microfluidic capacitors and 10 percent is dielectric tendon material. The optimal muscle to tendon ratio from the data gathered on the gap array simulations is approximately 75 to 25, meaning 75 percent of the surface area of the XY plane are microfluidic capacitors, and 25 percent is both the dielectric material and gaps.","abstract_html":"The technology that we focused on was the biomimetic actuation of microfluidic microcapacitors, which are electrostatically actuated structures that contract and function like biological muscles. Our thesis aims to find the optimal muscle-to-tendon ratio while expanding both the standard and gap design arrays and to find the respective force-density saturation values so predicted force output can be calculated for muscle fibers of a practical size. We also studied if a 3D virtual object can be a suitable model for the human operators’ examination of the artificial muscle and the optimization of its structure. Our results showed a maximum force density saturation of 8800 Pa and 6700 Pa when simulating the standard and gap array respectively with planar polarity wired artificial muscles. The optimal muscle-to-tendon ratio from the data gathered on the standard array simulations is approximately 9 to 1, meaning 90 percent of the surface area of the XY plane represents microfluidic capacitors and 10 percent is dielectric tendon material. The optimal muscle to tendon ratio from the data gathered on the gap array simulations is approximately 75 to 25, meaning 75 percent of the surface area of the XY plane are microfluidic capacitors, and 25 percent is both the dielectric material and gaps.","abstract_has_math":false,"creators":["Keeven, Joshua M.","Leckie, Jacob M."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Modeling, Virtual Environments, and Simulation","degree_level":"Masters","degree_discipline":"Modeling, Virtual Environments, and Simulation","degree_department":"Computer Science (CS)","school":null,"contributors":[],"advisors":["Sadagic, Amela","Kartalov, Emil P."],"committee_chairs":[],"committee_members":["Kennedy, Quinn"],"year":2022,"date_issued":"2022-06","date_published":"2022-06","updated_at":"2026-11-19T06:41:15Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["399, Modeling, Virtual Environments & Simulation"],"render_values":[{"text":"399, Modeling, Virtual Environments & Simulation","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["37050"],"render_values":[{"text":"37050","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/70703","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/70703","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F70703","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F70703","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sadagic, Amela","Kartalov, Emil P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kennedy, Quinn"]},{"key":"dc:contributor.department","label":"Department","values":["Computer Science (CS)"]},{"key":"dc:creator","label":"Author","values":["Keeven, Joshua M.","Leckie, Jacob M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-09-20T20:51:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-09-20T20:51:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Modeling, Virtual Environments, and Simulation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Modeling, Virtual Environments, and Simulation"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["37050"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["artificial muscles","microfluidic capacitors","biomimetic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["399, Modeling, Virtual Environments & Simulation"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/70703"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The technology that we focused on was the biomimetic actuation of microfluidic microcapacitors, which are electrostatically actuated structures that contract and function like biological muscles. Our thesis aims to find the optimal muscle-to-tendon ratio while expanding both the standard and gap design arrays and to find the respective force-density saturation values so predicted force output can be calculated for muscle fibers of a practical size. We also studied if a 3D virtual object can be a suitable model for the human operators’ examination of the artificial muscle and the optimization of its structure. Our results showed a maximum force density saturation of 8800 Pa and 6700 Pa when simulating the standard and gap array respectively with planar polarity wired artificial muscles. The optimal muscle-to-tendon ratio from the data gathered on the standard array simulations is approximately 9 to 1, meaning 90 percent of the surface area of the XY plane represents microfluidic capacitors and 10 percent is dielectric tendon material. The optimal muscle to tendon ratio from the data gathered on the gap array simulations is approximately 75 to 25, meaning 75 percent of the surface area of the XY plane are microfluidic capacitors, and 25 percent is both the dielectric material and gaps."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Office of Naval Research, Arlington, VA, 22203-1995"]},{"key":"dc:title","label":"Title","values":["MODELING AND SIMULATIONS FOR OPTIMIZATION OF MICROFLUIDIC MICROCAPACITOR ARRAYS OF BIOMIMETIC ARTIFICIAL MUSCLES FOR QUIET PROPULSION AND EXOSKELETAL LOCOMOTION"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Marine Corps"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sadagic, Amela","Kartalov, Emil P."],"dc:contributor.committeemember":["Kennedy, Quinn"],"dc:contributor.department":["Computer Science (CS)"],"dc:creator":["Keeven, Joshua M.","Leckie, Jacob M."],"dc:date.accessioned":["2022-09-20T20:51:21Z"],"dc:date.available":["2022-09-20T20:51:21Z"],"dc:date.issued":["2022-06"],"dc:description.abstract":["The technology that we focused on was the biomimetic actuation of microfluidic microcapacitors, which are electrostatically actuated structures that contract and function like biological muscles. Our thesis aims to find the optimal muscle-to-tendon ratio while expanding both the standard and gap design arrays and to find the respective force-density saturation values so predicted force output can be calculated for muscle fibers of a practical size. We also studied if a 3D virtual object can be a suitable model for the human operators’ examination of the artificial muscle and the optimization of its structure. Our results showed a maximum force density saturation of 8800 Pa and 6700 Pa when simulating the standard and gap array respectively with planar polarity wired artificial muscles. The optimal muscle-to-tendon ratio from the data gathered on the standard array simulations is approximately 9 to 1, meaning 90 percent of the surface area of the XY plane represents microfluidic capacitors and 10 percent is dielectric tendon material. The optimal muscle to tendon ratio from the data gathered on the gap array simulations is approximately 75 to 25, meaning 75 percent of the surface area of the XY plane are microfluidic capacitors, and 25 percent is both the dielectric material and gaps."],"dc:description.award":["Outstanding Thesis"],"dc:description.sponsorship":["Office of Naval Research, Arlington, VA, 22203-1995"],"dc:identifier.programcode":["399, Modeling, Virtual Environments & Simulation"],"dc:identifier.uri":["https://hdl.handle.net/10945/70703"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"dc:subject.keyword":["artificial muscles","microfluidic capacitors","biomimetic"],"dc:title":["MODELING AND SIMULATIONS FOR OPTIMIZATION OF MICROFLUIDIC MICROCAPACITOR ARRAYS OF BIOMIMETIC ARTIFICIAL MUSCLES FOR QUIET PROPULSION AND EXOSKELETAL LOCOMOTION"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Marine Corps"],"thesis:degree_discipline":["Modeling, Virtual Environments, and Simulation"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Modeling, Virtual Environments, and Simulation"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["37050"]},"updated_at":"2026-11-19T06:41:15Z"}