{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/71115"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/71115","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"SIMULTANEOUS DUAL LASER STABILIZATION FOR STRONTIUM ATOM INTERFEROMETRY","abstract":"The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap.","abstract_html":"The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap.","abstract_has_math":false,"creators":["Spakowski, Matthew D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":["Narducci, Frank A."],"committee_chairs":[],"committee_members":["Karunasiri, Gamani"],"year":2022,"date_issued":"2022-09","date_published":"2022-09","updated_at":"2026-11-26T00:03:03Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["533, Applied Physics of Combat Systems"],"render_values":[{"text":"533, Applied Physics of Combat Systems","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["36765"],"render_values":[{"text":"36765","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/71115","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/71115","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F71115","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F71115","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Narducci, Frank A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Karunasiri, Gamani"]},{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Spakowski, Matthew D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-11-17T20:55:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-11-17T20:55:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["36765"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["atom interferometry","laser cooling","strontium","magneto-optical trap"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["533, Applied Physics of Combat Systems"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/71115"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Army Research Office, Research Triangle, NC, 277703"]},{"key":"dc:title","label":"Title","values":["SIMULTANEOUS DUAL LASER STABILIZATION FOR STRONTIUM ATOM INTERFEROMETRY"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Narducci, Frank A."],"dc:contributor.committeemember":["Karunasiri, Gamani"],"dc:contributor.department":["Physics (PH)"],"dc:creator":["Spakowski, Matthew D."],"dc:date.accessioned":["2022-11-17T20:55:28Z"],"dc:date.available":["2022-11-17T20:55:28Z"],"dc:date.issued":["2022-09"],"dc:description.abstract":["The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap."],"dc:description.award":["Outstanding Thesis"],"dc:description.sponsorship":["Army Research Office, Research Triangle, NC, 277703"],"dc:identifier.programcode":["533, Applied Physics of Combat Systems"],"dc:identifier.uri":["https://hdl.handle.net/10945/71115"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"dc:subject.keyword":["atom interferometry","laser cooling","strontium","magneto-optical trap"],"dc:title":["SIMULTANEOUS DUAL LASER STABILIZATION FOR STRONTIUM ATOM INTERFEROMETRY"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Physics"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["36765"]},"updated_at":"2026-11-26T00:03:03Z"}