{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/71455"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/71455","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"EXPERIMENTAL ASSESSMENT OF A NOVEL DUAL OPENING DEWAR FOR USE ON A LIQUID AIR ENERGY STORAGE SYSTEM INSTALLED ON REMOTE, ISLANDED, RENEWABLE MILITARY MICROGRIDS","abstract":"Islanded, renewable energy microgrids for use at remote Department of Defense (DOD) facilities reduce logistical burdens associated with fossil fuel–based electrical power sources and provide greater operational flexibility; however, energy generation can be intrinsically intermittent on these microgrids. This intermittent electrical generation can be mitigated with energy storage. Liquid air energy storage (LAES) is one promising technology proposed to meet this energy storage issue due to its high energy density. Small-scale microgrids may not have enough excess capacity to store pressurized liquid air (LA), and instead may rely on unpressurized LA storage and their associated unpressurized power recovery options. Using commercial off-the-shelf components, this thesis conducts a comparative tradespace study for a variety of dual opening, unpressurized Dewar designs for use with Stirling- or Peltier-based power recovery cycles. The dual opening design is found to not be efficacious for short-term storage necessary for microgrid use due to excessive conductive losses to the outer Dewar shell; however, the design may be useful as an LA receiver and immediate-use energy storage medium for a connected Stirling generator. A proposed alternative solution using Dewar self-pressurization for LA storage and transport for DOD microgrid applications is presented for future work.","abstract_html":"Islanded, renewable energy microgrids for use at remote Department of Defense (DOD) facilities reduce logistical burdens associated with fossil fuel–based electrical power sources and provide greater operational flexibility; however, energy generation can be intrinsically intermittent on these microgrids. This intermittent electrical generation can be mitigated with energy storage. Liquid air energy storage (LAES) is one promising technology proposed to meet this energy storage issue due to its high energy density. Small-scale microgrids may not have enough excess capacity to store pressurized liquid air (LA), and instead may rely on unpressurized LA storage and their associated unpressurized power recovery options. Using commercial off-the-shelf components, this thesis conducts a comparative tradespace study for a variety of dual opening, unpressurized Dewar designs for use with Stirling- or Peltier-based power recovery cycles. The dual opening design is found to not be efficacious for short-term storage necessary for microgrid use due to excessive conductive losses to the outer Dewar shell; however, the design may be useful as an LA receiver and immediate-use energy storage medium for a connected Stirling generator. A proposed alternative solution using Dewar self-pressurization for LA storage and transport for DOD microgrid applications is presented for future work.","abstract_has_math":false,"creators":["Fackrell, Christofer J."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Systems Engineering","degree_level":"Masters","degree_discipline":"Systems Engineering","degree_department":"Systems Engineering (SE)","school":null,"contributors":[],"advisors":["Gannon, Anthony J.","Pollman, Anthony G.","Van Bossuyt, Douglas L."],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-12","date_published":"2022-12","updated_at":"2026-11-19T06:41:48Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"],"render_values":[{"text":"580, Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38484"],"render_values":[{"text":"38484","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/71455","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/71455","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F71455","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gannon, Anthony J.","Pollman, Anthony G.","Van Bossuyt, Douglas L."]},{"key":"dc:contributor.department","label":"Department","values":["Systems Engineering (SE)"]},{"key":"dc:creator","label":"Author","values":["Fackrell, Christofer J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-02-14T04:22:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-14T04:22:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Systems Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38484"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Dewar","liquid air","liquid air energy storage","renewable microgrid","islanded microgrid","remote microgrid","Stirling generator","Stirling cryocooler","Peltier thermoelectric generator","LAES","LA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/71455"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Islanded, renewable energy microgrids for use at remote Department of Defense (DOD) facilities reduce logistical burdens associated with fossil fuel–based electrical power sources and provide greater operational flexibility; however, energy generation can be intrinsically intermittent on these microgrids. This intermittent electrical generation can be mitigated with energy storage. Liquid air energy storage (LAES) is one promising technology proposed to meet this energy storage issue due to its high energy density. Small-scale microgrids may not have enough excess capacity to store pressurized liquid air (LA), and instead may rely on unpressurized LA storage and their associated unpressurized power recovery options. Using commercial off-the-shelf components, this thesis conducts a comparative tradespace study for a variety of dual opening, unpressurized Dewar designs for use with Stirling- or Peltier-based power recovery cycles. The dual opening design is found to not be efficacious for short-term storage necessary for microgrid use due to excessive conductive losses to the outer Dewar shell; however, the design may be useful as an LA receiver and immediate-use energy storage medium for a connected Stirling generator. A proposed alternative solution using Dewar self-pressurization for LA storage and transport for DOD microgrid applications is presented for future work."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:title","label":"Title","values":["EXPERIMENTAL ASSESSMENT OF A NOVEL DUAL OPENING DEWAR FOR USE ON A LIQUID AIR ENERGY STORAGE SYSTEM INSTALLED ON REMOTE, ISLANDED, RENEWABLE MILITARY MICROGRIDS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gannon, Anthony J.","Pollman, Anthony G.","Van Bossuyt, Douglas L."],"dc:contributor.department":["Systems Engineering (SE)"],"dc:creator":["Fackrell, Christofer J."],"dc:date.accessioned":["2023-02-14T04:22:31Z"],"dc:date.available":["2023-02-14T04:22:31Z"],"dc:date.issued":["2022-12"],"dc:description.abstract":["Islanded, renewable energy microgrids for use at remote Department of Defense (DOD) facilities reduce logistical burdens associated with fossil fuel–based electrical power sources and provide greater operational flexibility; however, energy generation can be intrinsically intermittent on these microgrids. This intermittent electrical generation can be mitigated with energy storage. Liquid air energy storage (LAES) is one promising technology proposed to meet this energy storage issue due to its high energy density. Small-scale microgrids may not have enough excess capacity to store pressurized liquid air (LA), and instead may rely on unpressurized LA storage and their associated unpressurized power recovery options. Using commercial off-the-shelf components, this thesis conducts a comparative tradespace study for a variety of dual opening, unpressurized Dewar designs for use with Stirling- or Peltier-based power recovery cycles. The dual opening design is found to not be efficacious for short-term storage necessary for microgrid use due to excessive conductive losses to the outer Dewar shell; however, the design may be useful as an LA receiver and immediate-use energy storage medium for a connected Stirling generator. A proposed alternative solution using Dewar self-pressurization for LA storage and transport for DOD microgrid applications is presented for future work."],"dc:description.award":["Outstanding Thesis"],"dc:identifier.programcode":["580, Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/71455"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"dc:subject.keyword":["Dewar","liquid air","liquid air energy storage","renewable microgrid","islanded microgrid","remote microgrid","Stirling generator","Stirling cryocooler","Peltier thermoelectric generator","LAES","LA"],"dc:title":["EXPERIMENTAL ASSESSMENT OF A NOVEL DUAL OPENING DEWAR FOR USE ON A LIQUID AIR ENERGY STORAGE SYSTEM INSTALLED ON REMOTE, ISLANDED, RENEWABLE MILITARY MICROGRIDS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Systems Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Systems Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["38484"]},"updated_at":"2026-11-19T06:41:48Z"}