{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/71480"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/71480","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"MODELING OF ULTRASONIC INSPECTION METHODS FOR GENERATION IV REACTORS","abstract":"The Lead-cooled Fast Reactor (LFR), a prominent category of Generation IV advanced reactors, involves design challenges for reactor plant in-service inspection (ISI) due to high operating temperatures, coolant opacities that prevent visual inspection, and the tendency for coolant corrosive attack. These challenges limit the feasibility and effectiveness of conventional ISI technologies. To overcome these challenges, acoustic methods that can operate under high temperature conditions are being actively considered in the U.S. as well as internationally. This research investigates the application of ultrasonic transducers, either piezoelectric or electro-magnetic, for LFR inspections. COMSOL Multiphysics software is used to model the effectiveness of thickness measurements, defect detections, and acoustic reflectance, for the reactor vessel and components within or in contact with the coolant. Acoustic absorption due to wave propagation through molten lead is also investigated. The models were designed in conjunction with future experimental work to provide comparison data between theory and experiment.","abstract_html":"The Lead-cooled Fast Reactor (LFR), a prominent category of Generation IV advanced reactors, involves design challenges for reactor plant in-service inspection (ISI) due to high operating temperatures, coolant opacities that prevent visual inspection, and the tendency for coolant corrosive attack. These challenges limit the feasibility and effectiveness of conventional ISI technologies. To overcome these challenges, acoustic methods that can operate under high temperature conditions are being actively considered in the U.S. as well as internationally. This research investigates the application of ultrasonic transducers, either piezoelectric or electro-magnetic, for LFR inspections. COMSOL Multiphysics software is used to model the effectiveness of thickness measurements, defect detections, and acoustic reflectance, for the reactor vessel and components within or in contact with the coolant. Acoustic absorption due to wave propagation through molten lead is also investigated. The models were designed in conjunction with future experimental work to provide comparison data between theory and experiment.","abstract_has_math":false,"creators":["Hutton, Nicholas J."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":["Smith, Craig F.","Grbovic, Dragoslav"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-12","date_published":"2022-12","updated_at":"2026-11-19T06:41:48Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["533, Applied Physics of Combat Systems"],"render_values":[{"text":"533, Applied Physics of Combat Systems","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38277"],"render_values":[{"text":"38277","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/71480","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/71480","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F71480","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Smith, Craig F.","Grbovic, Dragoslav"]},{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Hutton, Nicholas J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-02-14T04:22:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-14T04:22:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38277"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["ultrasonic","inservice","inspection","nuclear","reactor","model","COMSOL"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["533, Applied Physics of Combat Systems"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/71480"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Lead-cooled Fast Reactor (LFR), a prominent category of Generation IV advanced reactors, involves design challenges for reactor plant in-service inspection (ISI) due to high operating temperatures, coolant opacities that prevent visual inspection, and the tendency for coolant corrosive attack. These challenges limit the feasibility and effectiveness of conventional ISI technologies. To overcome these challenges, acoustic methods that can operate under high temperature conditions are being actively considered in the U.S. as well as internationally. This research investigates the application of ultrasonic transducers, either piezoelectric or electro-magnetic, for LFR inspections. COMSOL Multiphysics software is used to model the effectiveness of thickness measurements, defect detections, and acoustic reflectance, for the reactor vessel and components within or in contact with the coolant. Acoustic absorption due to wave propagation through molten lead is also investigated. The models were designed in conjunction with future experimental work to provide comparison data between theory and experiment."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Department of Energy, Livermore, CA 94950"]},{"key":"dc:title","label":"Title","values":["MODELING OF ULTRASONIC INSPECTION METHODS FOR GENERATION IV REACTORS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Smith, Craig F.","Grbovic, Dragoslav"],"dc:contributor.department":["Physics (PH)"],"dc:creator":["Hutton, Nicholas J."],"dc:date.accessioned":["2023-02-14T04:22:42Z"],"dc:date.available":["2023-02-14T04:22:42Z"],"dc:date.issued":["2022-12"],"dc:description.abstract":["The Lead-cooled Fast Reactor (LFR), a prominent category of Generation IV advanced reactors, involves design challenges for reactor plant in-service inspection (ISI) due to high operating temperatures, coolant opacities that prevent visual inspection, and the tendency for coolant corrosive attack. These challenges limit the feasibility and effectiveness of conventional ISI technologies. To overcome these challenges, acoustic methods that can operate under high temperature conditions are being actively considered in the U.S. as well as internationally. This research investigates the application of ultrasonic transducers, either piezoelectric or electro-magnetic, for LFR inspections. COMSOL Multiphysics software is used to model the effectiveness of thickness measurements, defect detections, and acoustic reflectance, for the reactor vessel and components within or in contact with the coolant. Acoustic absorption due to wave propagation through molten lead is also investigated. The models were designed in conjunction with future experimental work to provide comparison data between theory and experiment."],"dc:description.award":["Outstanding Thesis"],"dc:description.sponsorship":["Department of Energy, Livermore, CA 94950"],"dc:identifier.programcode":["533, Applied Physics of Combat Systems"],"dc:identifier.uri":["https://hdl.handle.net/10945/71480"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"dc:subject.keyword":["ultrasonic","inservice","inspection","nuclear","reactor","model","COMSOL"],"dc:title":["MODELING OF ULTRASONIC INSPECTION METHODS FOR GENERATION IV REACTORS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["38277"]},"updated_at":"2026-11-19T06:41:48Z"}