{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/71552"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/71552","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"NOVEL CONTROL STRATEGIES FOR SHIPBOARD POWER CONVERSION SYSTEMS TO MEET THE PULSED LOAD REQUIREMENTS IN MIL-STD-1399","abstract":"Large, immediate changes in electrical loading cause stresses in power systems. In large power systems, such as the grid used in residential, commercial and industrial applications, the typical change in electrical loading is a very small percentage of the power ratings of the electrical generators. As such, abrupt changes in electrical loading will cause relatively little stress to the power system. In naval applications, however, the distribution systems have a much lower power rating, so the stresses from load changes are much more significant. This thesis presents a novel solution to reduce the undesired effects of these load changes. Through the use of an energy storage system (ESS), switch-mode DC power converter, and an engineered control scheme, the undesired effects of large pulsed loads may be mitigated. A physics-based model of the system was constructed to provide a proof of concept of the solution, and is verified utilizing a laboratory prototype. The simulated and experimental measurements are compared against the specified constraints provided in MIL-STD-1399.","abstract_html":"Large, immediate changes in electrical loading cause stresses in power systems. In large power systems, such as the grid used in residential, commercial and industrial applications, the typical change in electrical loading is a very small percentage of the power ratings of the electrical generators. As such, abrupt changes in electrical loading will cause relatively little stress to the power system. In naval applications, however, the distribution systems have a much lower power rating, so the stresses from load changes are much more significant. This thesis presents a novel solution to reduce the undesired effects of these load changes. Through the use of an energy storage system (ESS), switch-mode DC power converter, and an engineered control scheme, the undesired effects of large pulsed loads may be mitigated. A physics-based model of the system was constructed to provide a proof of concept of the solution, and is verified utilizing a laboratory prototype. The simulated and experimental measurements are compared against the specified constraints provided in MIL-STD-1399.","abstract_has_math":false,"creators":["Storm, Matthew P."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Oriti, Giovanna","Zhang, Di"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-12","date_published":"2022-12","updated_at":"2026-11-26T00:13:06Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"],"render_values":[{"text":"590, Electronic Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38414"],"render_values":[{"text":"38414","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/71552","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/71552","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F71552","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F71552","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oriti, Giovanna","Zhang, Di"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Storm, Matthew P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-02-14T04:23:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-14T04:23:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f4822f3e-2aea-40ad-9b4a-288607743ad7","e743f4d8-72d2-4b60-b0b8-89c1781ca5b0"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38414"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["bi-directional boost converter","MIL-STD-1399","voltage source inverter","pulsed load","energy storage system","grid-following"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/71552"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Large, immediate changes in electrical loading cause stresses in power systems. In large power systems, such as the grid used in residential, commercial and industrial applications, the typical change in electrical loading is a very small percentage of the power ratings of the electrical generators. As such, abrupt changes in electrical loading will cause relatively little stress to the power system. In naval applications, however, the distribution systems have a much lower power rating, so the stresses from load changes are much more significant. This thesis presents a novel solution to reduce the undesired effects of these load changes. Through the use of an energy storage system (ESS), switch-mode DC power converter, and an engineered control scheme, the undesired effects of large pulsed loads may be mitigated. A physics-based model of the system was constructed to provide a proof of concept of the solution, and is verified utilizing a laboratory prototype. The simulated and experimental measurements are compared against the specified constraints provided in MIL-STD-1399."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:title","label":"Title","values":["NOVEL CONTROL STRATEGIES FOR SHIPBOARD POWER CONVERSION SYSTEMS TO MEET THE PULSED LOAD REQUIREMENTS IN MIL-STD-1399"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oriti, Giovanna","Zhang, Di"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Storm, Matthew P."],"dc:date.accessioned":["2023-02-14T04:23:26Z"],"dc:date.available":["2023-02-14T04:23:26Z"],"dc:date.issued":["2022-12"],"dc:description.abstract":["Large, immediate changes in electrical loading cause stresses in power systems. In large power systems, such as the grid used in residential, commercial and industrial applications, the typical change in electrical loading is a very small percentage of the power ratings of the electrical generators. As such, abrupt changes in electrical loading will cause relatively little stress to the power system. In naval applications, however, the distribution systems have a much lower power rating, so the stresses from load changes are much more significant. This thesis presents a novel solution to reduce the undesired effects of these load changes. Through the use of an energy storage system (ESS), switch-mode DC power converter, and an engineered control scheme, the undesired effects of large pulsed loads may be mitigated. A physics-based model of the system was constructed to provide a proof of concept of the solution, and is verified utilizing a laboratory prototype. The simulated and experimental measurements are compared against the specified constraints provided in MIL-STD-1399."],"dc:description.award":["Outstanding Thesis"],"dc:identifier.programcode":["590, Electronic Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/71552"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["f4822f3e-2aea-40ad-9b4a-288607743ad7","e743f4d8-72d2-4b60-b0b8-89c1781ca5b0"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"dc:subject.keyword":["bi-directional boost converter","MIL-STD-1399","voltage source inverter","pulsed load","energy storage system","grid-following"],"dc:title":["NOVEL CONTROL STRATEGIES FOR SHIPBOARD POWER CONVERSION SYSTEMS TO MEET THE PULSED LOAD REQUIREMENTS IN MIL-STD-1399"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["38414"]},"updated_at":"2026-11-26T00:13:06Z"}