{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/72044"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/72044","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"DESIGN AND IMPLEMENTATION OF A DATA ACQUISITION SYSTEM WITH IN-SITU PICOAMMETER FOR AUTOMATED RELIABILITY TESTING","abstract":"In recent years, the military has been exploring the use of wide bandgap semiconductors (WBGS) such as gallium nitride (GaN) and silicon carbide (SiC) due to their promising material properties, as compared to silicon (Si). Understanding the reliability of these high-performance WBGS devices is paramount to their implementation in military systems. However, it remains to be tested because good-quality reliability data is needed, but it is difficult and expensive to produce. This thesis looks at the design and implementation of a modular reliability testing subsystem in the form of a novel data acquisition system. First, a system was designed to perform automated, in-situ leakage current measurements of up to four devices under test (DUT) with sub-nA resolution. Next, a wide sample of devices consisting of a resistor, two Zener diodes, a power diode, two GaN diodes, and a field effect transistor (FET) were subjected to various voltage sweep and reverse-bias tests that were recorded by the system. Finally, the results of those validation tests were processed and analyzed. The system achieved leakage current resolutions below 100 pA, demonstrating its ability to measure various devices.","abstract_html":"In recent years, the military has been exploring the use of wide bandgap semiconductors (WBGS) such as gallium nitride (GaN) and silicon carbide (SiC) due to their promising material properties, as compared to silicon (Si). Understanding the reliability of these high-performance WBGS devices is paramount to their implementation in military systems. However, it remains to be tested because good-quality reliability data is needed, but it is difficult and expensive to produce. This thesis looks at the design and implementation of a modular reliability testing subsystem in the form of a novel data acquisition system. First, a system was designed to perform automated, in-situ leakage current measurements of up to four devices under test (DUT) with sub-nA resolution. Next, a wide sample of devices consisting of a resistor, two Zener diodes, a power diode, two GaN diodes, and a field effect transistor (FET) were subjected to various voltage sweep and reverse-bias tests that were recorded by the system. Finally, the results of those validation tests were processed and analyzed. The system achieved leakage current resolutions below 100 pA, demonstrating its ability to measure various devices.","abstract_has_math":false,"creators":["Ramos, Richard A."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Weatherford, Todd R."],"committee_chairs":[],"committee_members":["Porter, Matthew A."],"year":2023,"date_issued":"2023-03","date_published":"2023-03","updated_at":"2026-11-19T06:41:48Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"],"render_values":[{"text":"590, Electronic Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38474"],"render_values":[{"text":"38474","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/72044","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/72044","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F72044","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Weatherford, Todd R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Porter, Matthew A."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Ramos, Richard A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-05-03T16:03:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-05-03T16:03:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["38474"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["HTOL","HTRB","reliability testing","GaN","gallium nitride","SiC","silicon carbide","WBG","wide bandgap","diode","high voltage","power devices","leakage current","in-situ measurement","low-side measurement","picoammeter","transimpedance amplifier","TIA","current feedback amplifier","stability","noise"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/72044"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In recent years, the military has been exploring the use of wide bandgap semiconductors (WBGS) such as gallium nitride (GaN) and silicon carbide (SiC) due to their promising material properties, as compared to silicon (Si). Understanding the reliability of these high-performance WBGS devices is paramount to their implementation in military systems. However, it remains to be tested because good-quality reliability data is needed, but it is difficult and expensive to produce. This thesis looks at the design and implementation of a modular reliability testing subsystem in the form of a novel data acquisition system. First, a system was designed to perform automated, in-situ leakage current measurements of up to four devices under test (DUT) with sub-nA resolution. Next, a wide sample of devices consisting of a resistor, two Zener diodes, a power diode, two GaN diodes, and a field effect transistor (FET) were subjected to various voltage sweep and reverse-bias tests that were recorded by the system. Finally, the results of those validation tests were processed and analyzed. The system achieved leakage current resolutions below 100 pA, demonstrating its ability to measure various devices."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["ONR Arlington, VA, 22217"]},{"key":"dc:title","label":"Title","values":["DESIGN AND IMPLEMENTATION OF A DATA ACQUISITION SYSTEM WITH IN-SITU PICOAMMETER FOR AUTOMATED RELIABILITY TESTING"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Marine Corps"]}]}],"canonical_facts":{"dc:contributor.advisor":["Weatherford, Todd R."],"dc:contributor.committeemember":["Porter, Matthew A."],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Ramos, Richard A."],"dc:date.accessioned":["2023-05-03T16:03:28Z"],"dc:date.available":["2023-05-03T16:03:28Z"],"dc:date.issued":["2023-03"],"dc:description.abstract":["In recent years, the military has been exploring the use of wide bandgap semiconductors (WBGS) such as gallium nitride (GaN) and silicon carbide (SiC) due to their promising material properties, as compared to silicon (Si). Understanding the reliability of these high-performance WBGS devices is paramount to their implementation in military systems. However, it remains to be tested because good-quality reliability data is needed, but it is difficult and expensive to produce. This thesis looks at the design and implementation of a modular reliability testing subsystem in the form of a novel data acquisition system. First, a system was designed to perform automated, in-situ leakage current measurements of up to four devices under test (DUT) with sub-nA resolution. Next, a wide sample of devices consisting of a resistor, two Zener diodes, a power diode, two GaN diodes, and a field effect transistor (FET) were subjected to various voltage sweep and reverse-bias tests that were recorded by the system. Finally, the results of those validation tests were processed and analyzed. The system achieved leakage current resolutions below 100 pA, demonstrating its ability to measure various devices."],"dc:description.sponsorship":["ONR Arlington, VA, 22217"],"dc:identifier.programcode":["590, Electronic Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/72044"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release. Distribution is unlimited."],"dc:subject.keyword":["HTOL","HTRB","reliability testing","GaN","gallium nitride","SiC","silicon carbide","WBG","wide bandgap","diode","high voltage","power devices","leakage current","in-situ measurement","low-side measurement","picoammeter","transimpedance amplifier","TIA","current feedback amplifier","stability","noise"],"dc:title":["DESIGN AND IMPLEMENTATION OF A DATA ACQUISITION SYSTEM WITH IN-SITU PICOAMMETER FOR AUTOMATED RELIABILITY TESTING"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Marine Corps"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["38474"]},"updated_at":"2026-11-19T06:41:48Z"}