{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/73335"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/73335","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"COST–BENEFIT MODELING OF MICROGRIDS FOR MILITARY INSTALLATIONS","abstract":"The Department of Defense (DoD) and Department of the Navy (DON) have highlighted the implementation of microgrids as a potential solution to enhance energy security for installations. The primary purpose of this research is to demonstrate a method for cost–benefit analysis of microgrids, specifically considering a quantified measure of resiliency. This thesis develops a methodology that takes into account cost estimating relationships (CERs) with measured benefits of solar, battery, and emergency diesel generators (EDGs), while maintaining a defined resiliency. A model was developed and applied to Naval Base Point Loma (NBPL). This resulted in a microgrid design that could provide 14 days of resiliency for a cost of five million dollars with a constraint on solar area. It also showed that the cost had a non-linear relationship with resiliency. This thesis recommends that installations utilize this model's methodology—or an adapted methodology with installation specific values—to estimate costs for microgrids that meet DoD and DON energy security requirements.","abstract_html":"The Department of Defense (DoD) and Department of the Navy (DON) have highlighted the implementation of microgrids as a potential solution to enhance energy security for installations. The primary purpose of this research is to demonstrate a method for cost–benefit analysis of microgrids, specifically considering a quantified measure of resiliency. This thesis develops a methodology that takes into account cost estimating relationships (CERs) with measured benefits of solar, battery, and emergency diesel generators (EDGs), while maintaining a defined resiliency. A model was developed and applied to Naval Base Point Loma (NBPL). This resulted in a microgrid design that could provide 14 days of resiliency for a cost of five million dollars with a constraint on solar area. It also showed that the cost had a non-linear relationship with resiliency. This thesis recommends that installations utilize this model&#x27;s methodology—or an adapted methodology with installation specific values—to estimate costs for microgrids that meet DoD and DON energy security requirements.","abstract_has_math":false,"creators":["Kujawski, Jarrod R."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Systems Engineering","degree_level":"Masters","degree_discipline":"Systems Engineering","degree_department":"Systems Engineering (SE)","school":null,"contributors":[],"advisors":["Giachetti, Ronald E."],"committee_chairs":[],"committee_members":["Sweeney, Joseph W., III"],"year":2024,"date_issued":"2024-09","date_published":"2024-09","updated_at":"2026-11-19T06:42:35Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"],"render_values":[{"text":"580, Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["39803"],"render_values":[{"text":"39803","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/73335","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/73335","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F73335","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F73335","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giachetti, Ronald E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sweeney, Joseph W., III"]},{"key":"dc:contributor.department","label":"Department","values":["Systems Engineering (SE)"]},{"key":"dc:creator","label":"Author","values":["Kujawski, Jarrod R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-11-01T19:14:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-11-01T19:14:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["73c095de-fa3b-4d63-8300-9b6aee5b4d62"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Systems Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["39803"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Department of Defense","DoD","Department of the Navy","DON","cost estimation relationship","CER","Naval Base Point Loma","NBPL","cost estimation","economic evaluation","resilience","microgrid","military","installation","photovoltaic","PV","battery","emergency diesel generator","EDG"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/73335"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Department of Defense (DoD) and Department of the Navy (DON) have highlighted the implementation of microgrids as a potential solution to enhance energy security for installations. The primary purpose of this research is to demonstrate a method for cost–benefit analysis of microgrids, specifically considering a quantified measure of resiliency. This thesis develops a methodology that takes into account cost estimating relationships (CERs) with measured benefits of solar, battery, and emergency diesel generators (EDGs), while maintaining a defined resiliency. A model was developed and applied to Naval Base Point Loma (NBPL). This resulted in a microgrid design that could provide 14 days of resiliency for a cost of five million dollars with a constraint on solar area. It also showed that the cost had a non-linear relationship with resiliency. This thesis recommends that installations utilize this model's methodology—or an adapted methodology with installation specific values—to estimate costs for microgrids that meet DoD and DON energy security requirements."]},{"key":"dc:title","label":"Title","values":["COST–BENEFIT MODELING OF MICROGRIDS FOR MILITARY INSTALLATIONS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giachetti, Ronald E."],"dc:contributor.committeemember":["Sweeney, Joseph W., III"],"dc:contributor.department":["Systems Engineering (SE)"],"dc:creator":["Kujawski, Jarrod R."],"dc:date.accessioned":["2024-11-01T19:14:32Z"],"dc:date.available":["2024-11-01T19:14:32Z"],"dc:date.issued":["2024-09"],"dc:description.abstract":["The Department of Defense (DoD) and Department of the Navy (DON) have highlighted the implementation of microgrids as a potential solution to enhance energy security for installations. The primary purpose of this research is to demonstrate a method for cost–benefit analysis of microgrids, specifically considering a quantified measure of resiliency. This thesis develops a methodology that takes into account cost estimating relationships (CERs) with measured benefits of solar, battery, and emergency diesel generators (EDGs), while maintaining a defined resiliency. A model was developed and applied to Naval Base Point Loma (NBPL). This resulted in a microgrid design that could provide 14 days of resiliency for a cost of five million dollars with a constraint on solar area. It also showed that the cost had a non-linear relationship with resiliency. This thesis recommends that installations utilize this model's methodology—or an adapted methodology with installation specific values—to estimate costs for microgrids that meet DoD and DON energy security requirements."],"dc:identifier.programcode":["580, Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/73335"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["73c095de-fa3b-4d63-8300-9b6aee5b4d62"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["Department of Defense","DoD","Department of the Navy","DON","cost estimation relationship","CER","Naval Base Point Loma","NBPL","cost estimation","economic evaluation","resilience","microgrid","military","installation","photovoltaic","PV","battery","emergency diesel generator","EDG"],"dc:title":["COST–BENEFIT MODELING OF MICROGRIDS FOR MILITARY INSTALLATIONS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Systems Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Systems Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["39803"]},"updated_at":"2026-11-19T06:42:35Z"}