{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/73374"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/73374","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"MOBILE MICROGRIDS AND THEIR CONTRIBUTION TOWARD ENERGY RESILIENCE AT ISOLATED DOD INSTALLATIONS","abstract":"This research builds upon a prior feasibility study on movable microgrids. It was previously demonstrated that a 10-kW movable microgrid could be housed in a TriCon shipping container and relocated when needed. To address the need for higher installation energy resilience in isolated locations, this study was conducted to increase power generation capability enabling the restoration of more structures amid power outages. A concept of operations was developed to understand the logistical considerations, such as the operational weight limitations with the MH-53E, leading to the selection of the BiCon shipping container. Through the fabrication of two fictious islands, representative of various remote military installations abroad, a study was conducted to determine the necessary power demand. Various commercial-off-the-shelf photovoltaic panels, diesel generators, and lithium-ion batteries were investigated and selected through an iterative sizing process that determined the final peak load capability of 68 kW. Modeling and simulation was conducted via an updated version of a previously developed back-of-the-envelope model and the NPS online microgrid planner. During these simulations, the mobile microgrid provided power to an average of 48% of the structures between the two fictitious islands. The simulations also demonstrated that the BiCon mobile microgrid could provide the structures with continuous power for 14 days, aligning with DOD energy resilience objectives.","abstract_html":"This research builds upon a prior feasibility study on movable microgrids. It was previously demonstrated that a 10-kW movable microgrid could be housed in a TriCon shipping container and relocated when needed. To address the need for higher installation energy resilience in isolated locations, this study was conducted to increase power generation capability enabling the restoration of more structures amid power outages. A concept of operations was developed to understand the logistical considerations, such as the operational weight limitations with the MH-53E, leading to the selection of the BiCon shipping container. Through the fabrication of two fictious islands, representative of various remote military installations abroad, a study was conducted to determine the necessary power demand. Various commercial-off-the-shelf photovoltaic panels, diesel generators, and lithium-ion batteries were investigated and selected through an iterative sizing process that determined the final peak load capability of 68 kW. Modeling and simulation was conducted via an updated version of a previously developed back-of-the-envelope model and the NPS online microgrid planner. During these simulations, the mobile microgrid provided power to an average of 48% of the structures between the two fictitious islands. The simulations also demonstrated that the BiCon mobile microgrid could provide the structures with continuous power for 14 days, aligning with DOD energy resilience objectives.","abstract_has_math":false,"creators":["Staley, Andrew J."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Systems Engineering","degree_level":"Masters","degree_discipline":"Systems Engineering","degree_department":"Systems Engineering (SE)","school":null,"contributors":[],"advisors":["Moore, Hyatt E., IV","Van Bossuyt, Douglas L."],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-09","date_published":"2024-09","updated_at":"2026-11-19T06:42:35Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"],"render_values":[{"text":"580, Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["39809"],"render_values":[{"text":"39809","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/73374","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/73374","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F73374","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F73374","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Moore, Hyatt E., IV","Van Bossuyt, Douglas L."]},{"key":"dc:contributor.department","label":"Department","values":["Systems Engineering (SE)"]},{"key":"dc:creator","label":"Author","values":["Staley, Andrew J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-11-01T19:16:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-11-01T19:16:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["73c095de-fa3b-4d63-8300-9b6aee5b4d62"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Systems Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["39809"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["microgrid","decarbonization","resilience","energy security","mobile microgrid","remote operations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/73374"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research builds upon a prior feasibility study on movable microgrids. It was previously demonstrated that a 10-kW movable microgrid could be housed in a TriCon shipping container and relocated when needed. To address the need for higher installation energy resilience in isolated locations, this study was conducted to increase power generation capability enabling the restoration of more structures amid power outages. A concept of operations was developed to understand the logistical considerations, such as the operational weight limitations with the MH-53E, leading to the selection of the BiCon shipping container. Through the fabrication of two fictious islands, representative of various remote military installations abroad, a study was conducted to determine the necessary power demand. Various commercial-off-the-shelf photovoltaic panels, diesel generators, and lithium-ion batteries were investigated and selected through an iterative sizing process that determined the final peak load capability of 68 kW. Modeling and simulation was conducted via an updated version of a previously developed back-of-the-envelope model and the NPS online microgrid planner. During these simulations, the mobile microgrid provided power to an average of 48% of the structures between the two fictitious islands. The simulations also demonstrated that the BiCon mobile microgrid could provide the structures with continuous power for 14 days, aligning with DOD energy resilience objectives."]},{"key":"dc:title","label":"Title","values":["MOBILE MICROGRIDS AND THEIR CONTRIBUTION TOWARD ENERGY RESILIENCE AT ISOLATED DOD INSTALLATIONS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Moore, Hyatt E., IV","Van Bossuyt, Douglas L."],"dc:contributor.department":["Systems Engineering (SE)"],"dc:creator":["Staley, Andrew J."],"dc:date.accessioned":["2024-11-01T19:16:01Z"],"dc:date.available":["2024-11-01T19:16:01Z"],"dc:date.issued":["2024-09"],"dc:description.abstract":["This research builds upon a prior feasibility study on movable microgrids. It was previously demonstrated that a 10-kW movable microgrid could be housed in a TriCon shipping container and relocated when needed. To address the need for higher installation energy resilience in isolated locations, this study was conducted to increase power generation capability enabling the restoration of more structures amid power outages. A concept of operations was developed to understand the logistical considerations, such as the operational weight limitations with the MH-53E, leading to the selection of the BiCon shipping container. Through the fabrication of two fictious islands, representative of various remote military installations abroad, a study was conducted to determine the necessary power demand. Various commercial-off-the-shelf photovoltaic panels, diesel generators, and lithium-ion batteries were investigated and selected through an iterative sizing process that determined the final peak load capability of 68 kW. Modeling and simulation was conducted via an updated version of a previously developed back-of-the-envelope model and the NPS online microgrid planner. During these simulations, the mobile microgrid provided power to an average of 48% of the structures between the two fictitious islands. The simulations also demonstrated that the BiCon mobile microgrid could provide the structures with continuous power for 14 days, aligning with DOD energy resilience objectives."],"dc:identifier.programcode":["580, Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/73374"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["73c095de-fa3b-4d63-8300-9b6aee5b4d62"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["microgrid","decarbonization","resilience","energy security","mobile microgrid","remote operations"],"dc:title":["MOBILE MICROGRIDS AND THEIR CONTRIBUTION TOWARD ENERGY RESILIENCE AT ISOLATED DOD INSTALLATIONS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Systems Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Systems Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["39809"]},"updated_at":"2026-11-19T06:42:35Z"}