{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/74057"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/74057","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"EXPERIMENTAL ACCURACY OF NILM LOAD DISAGGREGATION ON THREE-PHASE MICROGRID TEST BED","abstract":"Non-intrusive load monitoring (NILM) is a powerful tool that uses machine learning and special sensors to disaggregate large amounts of electrical data from a single central point of a power system. This service provides valuable insight into the system, allowing for anomaly detection and improvements to preventative maintenance. An important aspect of NILM is the accuracy of the sensors collecting the power data. The United States Navy is currently experimenting with the Mobile Power Meter (MPM), a load monitoring sensor that is proprietary to the Army Research Lab (ARL). These sensors are still being tested, optimized, and improved with every iteration. MPMs have not yet been validated for widespread use. In this thesis, we test the accuracy of MPM data collection and load disaggregation when applied to a three-phase microgrid testbed. The MPMs are run through tests with various loads and then meticulously compared to the ground truth data, which is obtained from oscilloscope probes attached at every phase of every load. Various power features, such as the frequency, voltage, and phase currents, are then selected for analysis. Based on percent error calculations and visual analysis, the MPM data is compared against the oscilloscopes for accuracy. Validating the accuracy of the MPMs is a significant step in ensuring NILM is precisely executed, thereby bolstering the energy security of the United States Navy.","abstract_html":"Non-intrusive load monitoring (NILM) is a powerful tool that uses machine learning and special sensors to disaggregate large amounts of electrical data from a single central point of a power system. This service provides valuable insight into the system, allowing for anomaly detection and improvements to preventative maintenance. An important aspect of NILM is the accuracy of the sensors collecting the power data. The United States Navy is currently experimenting with the Mobile Power Meter (MPM), a load monitoring sensor that is proprietary to the Army Research Lab (ARL). These sensors are still being tested, optimized, and improved with every iteration. MPMs have not yet been validated for widespread use. In this thesis, we test the accuracy of MPM data collection and load disaggregation when applied to a three-phase microgrid testbed. The MPMs are run through tests with various loads and then meticulously compared to the ground truth data, which is obtained from oscilloscope probes attached at every phase of every load. Various power features, such as the frequency, voltage, and phase currents, are then selected for analysis. Based on percent error calculations and visual analysis, the MPM data is compared against the oscilloscopes for accuracy. Validating the accuracy of the MPMs is a significant step in ensuring NILM is precisely executed, thereby bolstering the energy security of the United States Navy.","abstract_has_math":false,"creators":["Chrise, Joseph D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Oriti, Giovanna","Thulasiraman, Preetha"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-06","date_published":"2025-06","updated_at":"2026-11-19T06:43:09Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"],"render_values":[{"text":"590, Electronic Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["41282"],"render_values":[{"text":"41282","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/74057","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/74057","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F74057","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F74057","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oriti, Giovanna","Thulasiraman, Preetha"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Chrise, Joseph D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-09-08T15:39:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-09-08T15:39:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f4822f3e-2aea-40ad-9b4a-288607743ad7","e5065ddf-384c-454e-90a9-05a86e1c1a3a"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88110183-ea50-46f5-b469-809c1418a16d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["41282"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["non-intrusive load monitoring","NILM","microgrid","disaggregation","power signature","load monitoring","clustering","energy efficiency","fault detection","anomaly detection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["590, Electronic Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/74057"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Non-intrusive load monitoring (NILM) is a powerful tool that uses machine learning and special sensors to disaggregate large amounts of electrical data from a single central point of a power system. This service provides valuable insight into the system, allowing for anomaly detection and improvements to preventative maintenance. An important aspect of NILM is the accuracy of the sensors collecting the power data. The United States Navy is currently experimenting with the Mobile Power Meter (MPM), a load monitoring sensor that is proprietary to the Army Research Lab (ARL). These sensors are still being tested, optimized, and improved with every iteration. MPMs have not yet been validated for widespread use. In this thesis, we test the accuracy of MPM data collection and load disaggregation when applied to a three-phase microgrid testbed. The MPMs are run through tests with various loads and then meticulously compared to the ground truth data, which is obtained from oscilloscope probes attached at every phase of every load. Various power features, such as the frequency, voltage, and phase currents, are then selected for analysis. Based on percent error calculations and visual analysis, the MPM data is compared against the oscilloscopes for accuracy. Validating the accuracy of the MPMs is a significant step in ensuring NILM is precisely executed, thereby bolstering the energy security of the United States Navy."]},{"key":"dc:title","label":"Title","values":["EXPERIMENTAL ACCURACY OF NILM LOAD DISAGGREGATION ON THREE-PHASE MICROGRID TEST BED"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Ensign, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oriti, Giovanna","Thulasiraman, Preetha"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Chrise, Joseph D."],"dc:date.accessioned":["2025-09-08T15:39:23Z"],"dc:date.available":["2025-09-08T15:39:23Z"],"dc:date.issued":["2025-06"],"dc:description.abstract":["Non-intrusive load monitoring (NILM) is a powerful tool that uses machine learning and special sensors to disaggregate large amounts of electrical data from a single central point of a power system. This service provides valuable insight into the system, allowing for anomaly detection and improvements to preventative maintenance. An important aspect of NILM is the accuracy of the sensors collecting the power data. The United States Navy is currently experimenting with the Mobile Power Meter (MPM), a load monitoring sensor that is proprietary to the Army Research Lab (ARL). These sensors are still being tested, optimized, and improved with every iteration. MPMs have not yet been validated for widespread use. In this thesis, we test the accuracy of MPM data collection and load disaggregation when applied to a three-phase microgrid testbed. The MPMs are run through tests with various loads and then meticulously compared to the ground truth data, which is obtained from oscilloscope probes attached at every phase of every load. Various power features, such as the frequency, voltage, and phase currents, are then selected for analysis. Based on percent error calculations and visual analysis, the MPM data is compared against the oscilloscopes for accuracy. Validating the accuracy of the MPMs is a significant step in ensuring NILM is precisely executed, thereby bolstering the energy security of the United States Navy."],"dc:identifier.programcode":["590, Electronic Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/74057"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["f4822f3e-2aea-40ad-9b4a-288607743ad7","e5065ddf-384c-454e-90a9-05a86e1c1a3a"],"dc:relation.orgunit":["88110183-ea50-46f5-b469-809c1418a16d"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["non-intrusive load monitoring","NILM","microgrid","disaggregation","power signature","load monitoring","clustering","energy efficiency","fault detection","anomaly detection"],"dc:title":["EXPERIMENTAL ACCURACY OF NILM LOAD DISAGGREGATION ON THREE-PHASE MICROGRID TEST BED"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Ensign, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["41282"]},"updated_at":"2026-11-19T06:43:09Z"}