{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/7464"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/7464","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Modeling and experimental testing for future development of Night Vision Electro-Optic (NVEO) FLIR92 Model","abstract":"Recent advances in thermal imaging technology have resulted in the fielding of two-dimensional array detector based imaging systems. These designs have been labeled second-generation, and are rapidly replacing first generation systems having linear detector arrays with a parallel scan type architecture. It has been postulated that first generation prediction models are not applicable to second generation systems. In particular, the minimum resolvable temperature difference (MRTD) modeling needs refinement in the areas of sampling, quantization noise, and array non-uniformities in order for it to be applied to second generation systems. The present industry standard for MRTD is the Night Vision FLIR92 Model. Results from the FLIR92 Model and the two well known first generation models will be presented and compared with experimental measurements made on two thermal imaging systems available at the Naval Postgraduate School.","abstract_html":"Recent advances in thermal imaging technology have resulted in the fielding of two-dimensional array detector based imaging systems. These designs have been labeled second-generation, and are rapidly replacing first generation systems having linear detector arrays with a parallel scan type architecture. It has been postulated that first generation prediction models are not applicable to second generation systems. In particular, the minimum resolvable temperature difference (MRTD) modeling needs refinement in the areas of sampling, quantization noise, and array non-uniformities in order for it to be applied to second generation systems. The present industry standard for MRTD is the Night Vision FLIR92 Model. Results from the FLIR92 Model and the two well known first generation models will be presented and compared with experimental measurements made on two thermal imaging systems available at the Naval Postgraduate School.","abstract_has_math":false,"creators":["Koc, Cem"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Systems Engineering (Electronic Warfare)","degree_level":"Masters","degree_discipline":"Systems Engineering (Electronic Warfare)","degree_department":null,"school":null,"contributors":[],"advisors":["Pieper, Ron J.","Cooper, Alfred W."],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995-12","date_published":"1995-12","updated_at":"2026-11-19T06:43:09Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/7464","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/7464","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F7464","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pieper, Ron J.","Cooper, Alfred W."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Information Warfare Academic Group"]},{"key":"dc:creator","label":"Author","values":["Koc, Cem"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-07-31T19:52:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-07-31T19:52:59Z"]},{"key":"dc:date.issued","label":"Date","values":["1995-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["3ca085ea-3ce5-45da-9273-fe2cbe728c6d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering (Electronic Warfare)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Systems Engineering (Electronic Warfare)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Thermal Imaging Systems","FLIR Performance","Minimal Resolvable Temperature Difference (MRTD)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/7464"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent advances in thermal imaging technology have resulted in the fielding of two-dimensional array detector based imaging systems. These designs have been labeled second-generation, and are rapidly replacing first generation systems having linear detector arrays with a parallel scan type architecture. It has been postulated that first generation prediction models are not applicable to second generation systems. In particular, the minimum resolvable temperature difference (MRTD) modeling needs refinement in the areas of sampling, quantization noise, and array non-uniformities in order for it to be applied to second generation systems. The present industry standard for MRTD is the Night Vision FLIR92 Model. Results from the FLIR92 Model and the two well known first generation models will be presented and compared with experimental measurements made on two thermal imaging systems available at the Naval Postgraduate School."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/modelingndexperi109457464"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["130 p."]},{"key":"dc:title","label":"Title","values":["Modeling and experimental testing for future development of Night Vision Electro-Optic (NVEO) FLIR92 Model"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Junior Grade, Turkish Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pieper, Ron J.","Cooper, Alfred W."],"dc:contributor.other":["Information Warfare Academic Group"],"dc:creator":["Koc, Cem"],"dc:date.accessioned":["2012-07-31T19:52:59Z"],"dc:date.available":["2012-07-31T19:52:59Z"],"dc:date.issued":["1995-12"],"dc:description.abstract":["Recent advances in thermal imaging technology have resulted in the fielding of two-dimensional array detector based imaging systems. These designs have been labeled second-generation, and are rapidly replacing first generation systems having linear detector arrays with a parallel scan type architecture. It has been postulated that first generation prediction models are not applicable to second generation systems. In particular, the minimum resolvable temperature difference (MRTD) modeling needs refinement in the areas of sampling, quantization noise, and array non-uniformities in order for it to be applied to second generation systems. The present industry standard for MRTD is the Night Vision FLIR92 Model. Results from the FLIR92 Model and the two well known first generation models will be presented and compared with experimental measurements made on two thermal imaging systems available at the Naval Postgraduate School."],"dc:description.uri":["http://archive.org/details/modelingndexperi109457464"],"dc:format.extent":["130 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/7464"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["3ca085ea-3ce5-45da-9273-fe2cbe728c6d"],"dc:rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Thermal Imaging Systems","FLIR Performance","Minimal Resolvable Temperature Difference (MRTD)"],"dc:title":["Modeling and experimental testing for future development of Night Vision Electro-Optic (NVEO) FLIR92 Model"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Junior Grade, Turkish Navy"],"thesis:degree_discipline":["Systems Engineering (Electronic Warfare)"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Systems Engineering (Electronic Warfare)"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:43:09Z"}