{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/7541"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/7541","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Solid rocket motor plume particle size measurements using multiple optical techniques in a probe","abstract":"An experimental investigation to measure particle size distributions in the plume of sub-scale solid rocket motors was conducted. A phase-Doppler particle analyzer (pDPA) in conjunction with three-wavelength extinction measurements were used in a specially designed particle collection probe in an attempt to determine the entire plume particle size distribution. In addition, a laser ensemble particle sizer was used for comparative data. The PDPA and Malvem distributions agreed in the observed modes near 1 and 4.5 mm diameter (d). Scanning Electron Microscope (SEM) pictures of collected particles were in good agreement with the measured Malvem Sauter Mean diameter (d,%) of 2.59 mm. Data analysis indicate that less than 3% of the total mass of the particles was contained in particles with diameter d <0.5 mm. Therefore, the PDPA, which can typically measure particles down to a minimum diameter of 0.5 mm with a dynamic range (d max:d min) of 50:1, can be used by itself to determine the particle size distribution. Multiple wavelength measurements were found to be very sensitive to inaccuracies in the measured transmittances.","abstract_html":"An experimental investigation to measure particle size distributions in the plume of sub-scale solid rocket motors was conducted. A phase-Doppler particle analyzer (pDPA) in conjunction with three-wavelength extinction measurements were used in a specially designed particle collection probe in an attempt to determine the entire plume particle size distribution. In addition, a laser ensemble particle sizer was used for comparative data. The PDPA and Malvem distributions agreed in the observed modes near 1 and 4.5 mm diameter (d). Scanning Electron Microscope (SEM) pictures of collected particles were in good agreement with the measured Malvem Sauter Mean diameter (d,%) of 2.59 mm. Data analysis indicate that less than 3% of the total mass of the particles was contained in particles with diameter d &lt;0.5 mm. Therefore, the PDPA, which can typically measure particles down to a minimum diameter of 0.5 mm with a dynamic range (d max:d min) of 50:1, can be used by itself to determine the particle size distribution. Multiple wavelength measurements were found to be very sensitive to inaccuracies in the measured transmittances.","abstract_has_math":false,"creators":["Manser, John R."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Astronautical Engineering","degree_level":"Masters","degree_discipline":"Astronautical Engineering","degree_department":"Astronautical Engineering","school":null,"contributors":[],"advisors":["Netzer, David W."],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995-03","date_published":"1995-03","updated_at":"2026-11-20T22:18:02Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/7541","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/7541","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F7541","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Netzer, David W."]},{"key":"dc:contributor.department","label":"Department","values":["Astronautical Engineering"]},{"key":"dc:creator","label":"Author","values":["Manser, John R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1995"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-07-31T19:54:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-07-31T19:54:11Z"]},{"key":"dc:date.issued","label":"Date","values":["1995-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Astronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/7541"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental investigation to measure particle size distributions in the plume of sub-scale solid rocket motors was conducted. A phase-Doppler particle analyzer (pDPA) in conjunction with three-wavelength extinction measurements were used in a specially designed particle collection probe in an attempt to determine the entire plume particle size distribution. In addition, a laser ensemble particle sizer was used for comparative data. The PDPA and Malvem distributions agreed in the observed modes near 1 and 4.5 mm diameter (d). Scanning Electron Microscope (SEM) pictures of collected particles were in good agreement with the measured Malvem Sauter Mean diameter (d,%) of 2.59 mm. Data analysis indicate that less than 3% of the total mass of the particles was contained in particles with diameter d <0.5 mm. Therefore, the PDPA, which can typically measure particles down to a minimum diameter of 0.5 mm with a dynamic range (d max:d min) of 50:1, can be used by itself to determine the particle size distribution. Multiple wavelength measurements were found to be very sensitive to inaccuracies in the measured transmittances."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/solidrocketmotor109457541"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["100 p."]},{"key":"dc:title","label":"Title","values":["Solid rocket motor plume particle size measurements using multiple optical techniques in a probe"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (U.S.N.) author."]}]}],"canonical_facts":{"dc:contributor.advisor":["Netzer, David W."],"dc:contributor.department":["Astronautical Engineering"],"dc:creator":["Manser, John R."],"dc:date":["March 1995"],"dc:date.accessioned":["2012-07-31T19:54:11Z"],"dc:date.available":["2012-07-31T19:54:11Z"],"dc:date.issued":["1995-03"],"dc:description.abstract":["An experimental investigation to measure particle size distributions in the plume of sub-scale solid rocket motors was conducted. A phase-Doppler particle analyzer (pDPA) in conjunction with three-wavelength extinction measurements were used in a specially designed particle collection probe in an attempt to determine the entire plume particle size distribution. In addition, a laser ensemble particle sizer was used for comparative data. The PDPA and Malvem distributions agreed in the observed modes near 1 and 4.5 mm diameter (d). Scanning Electron Microscope (SEM) pictures of collected particles were in good agreement with the measured Malvem Sauter Mean diameter (d,%) of 2.59 mm. Data analysis indicate that less than 3% of the total mass of the particles was contained in particles with diameter d <0.5 mm. Therefore, the PDPA, which can typically measure particles down to a minimum diameter of 0.5 mm with a dynamic range (d max:d min) of 50:1, can be used by itself to determine the particle size distribution. Multiple wavelength measurements were found to be very sensitive to inaccuracies in the measured transmittances."],"dc:description.uri":["http://archive.org/details/solidrocketmotor109457541"],"dc:format.extent":["100 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/7541"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:title":["Solid rocket motor plume particle size measurements using multiple optical techniques in a probe"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (U.S.N.) author."],"thesis:degree_discipline":["Astronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Astronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:18:02Z"}