{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/75922"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/75922","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"AUTONOMOUS ONBOARD CORRECTION OF INFRARED PIXEL RESPONSE FOR THE TERAHERTZ IMAGING CAMERA (TIC)","abstract":"This thesis examines calibration and detector correction methods for the CRIUS 1280 infrared camera used within the Terahertz Imaging Camera (TIC), a hybrid THz-to-IR imaging system designed to detect extremely small terahertz-induced temperature variations. Because TIC must measure temperature differences of only a few hundred millikelvin, detector nonuniformity, thermal drift, and fixed-pattern noise can significantly degrade image quality and sensing performance. This research develops and evaluates a reference-based calibration framework using two-point and one-point nonuniformity correction (NUC) techniques to maintain detector stability across thermal conditions representative of orbital operation aboard the International Space Station (ISS). Experimental testing using controlled thermal conditions and calibrated reference sources evaluated detector behavior, calibration effectiveness, and image stability across varying focal plane array temperatures. Results demonstrated that combining baseline two-point calibration with one-point offset correction significantly improved detector uniformity and reduced image degradation caused by thermal drift.","abstract_html":"This thesis examines calibration and detector correction methods for the CRIUS 1280 infrared camera used within the Terahertz Imaging Camera (TIC), a hybrid THz-to-IR imaging system designed to detect extremely small terahertz-induced temperature variations. Because TIC must measure temperature differences of only a few hundred millikelvin, detector nonuniformity, thermal drift, and fixed-pattern noise can significantly degrade image quality and sensing performance. This research develops and evaluates a reference-based calibration framework using two-point and one-point nonuniformity correction (NUC) techniques to maintain detector stability across thermal conditions representative of orbital operation aboard the International Space Station (ISS). Experimental testing using controlled thermal conditions and calibrated reference sources evaluated detector behavior, calibration effectiveness, and image stability across varying focal plane array temperatures. Results demonstrated that combining baseline two-point calibration with one-point offset correction significantly improved detector uniformity and reduced image degradation caused by thermal drift.","abstract_has_math":false,"creators":["McCowan, Joshua D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Space Systems Operations","degree_level":"Masters","degree_discipline":"Space Systems Operations","degree_department":null,"school":null,"contributors":[],"advisors":["Durante Pereira Alves, Fabio"],"committee_chairs":[],"committee_members":["Horning, James"],"year":2026,"date_issued":"2026-06","date_published":"2026-06","updated_at":"2026-11-19T06:44:00Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["366, Space Systems Operations"],"render_values":[{"text":"366, Space Systems Operations","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["40529"],"render_values":[{"text":"40529","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/75922","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/75922","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F75922","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F75922","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Durante Pereira Alves, Fabio"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Horning, James"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Space Systems Academic Group (SSAG)"]},{"key":"dc:creator","label":"Author","values":["McCowan, Joshua D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-08T19:58:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-08T19:58:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["5c0a02d8-a582-4b1a-9b41-2c1da92cb997"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["71422806-0ca0-4772-840b-075e219b82d9"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Space Systems Operations"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Space Systems Operations"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["40529"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["TIC","CRIUS 1280","infrared pixel correction","nonuniformity correction","autonomous tasking","onboard autonomy","ISS thermal environment","terahertz imaging","event detection","anomaly detection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["366, Space Systems Operations"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/75922"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis examines calibration and detector correction methods for the CRIUS 1280 infrared camera used within the Terahertz Imaging Camera (TIC), a hybrid THz-to-IR imaging system designed to detect extremely small terahertz-induced temperature variations. Because TIC must measure temperature differences of only a few hundred millikelvin, detector nonuniformity, thermal drift, and fixed-pattern noise can significantly degrade image quality and sensing performance. This research develops and evaluates a reference-based calibration framework using two-point and one-point nonuniformity correction (NUC) techniques to maintain detector stability across thermal conditions representative of orbital operation aboard the International Space Station (ISS). Experimental testing using controlled thermal conditions and calibrated reference sources evaluated detector behavior, calibration effectiveness, and image stability across varying focal plane array temperatures. Results demonstrated that combining baseline two-point calibration with one-point offset correction significantly improved detector uniformity and reduced image degradation caused by thermal drift."]},{"key":"dc:title","label":"Title","values":["AUTONOMOUS ONBOARD CORRECTION OF INFRARED PIXEL RESPONSE FOR THE TERAHERTZ IMAGING CAMERA (TIC)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Durante Pereira Alves, Fabio"],"dc:contributor.committeemember":["Horning, James"],"dc:contributor.other":["Space Systems Academic Group (SSAG)"],"dc:creator":["McCowan, Joshua D."],"dc:date.accessioned":["2026-09-08T19:58:48Z"],"dc:date.available":["2026-09-08T19:58:48Z"],"dc:date.issued":["2026-06"],"dc:description.abstract":["This thesis examines calibration and detector correction methods for the CRIUS 1280 infrared camera used within the Terahertz Imaging Camera (TIC), a hybrid THz-to-IR imaging system designed to detect extremely small terahertz-induced temperature variations. Because TIC must measure temperature differences of only a few hundred millikelvin, detector nonuniformity, thermal drift, and fixed-pattern noise can significantly degrade image quality and sensing performance. This research develops and evaluates a reference-based calibration framework using two-point and one-point nonuniformity correction (NUC) techniques to maintain detector stability across thermal conditions representative of orbital operation aboard the International Space Station (ISS). Experimental testing using controlled thermal conditions and calibrated reference sources evaluated detector behavior, calibration effectiveness, and image stability across varying focal plane array temperatures. Results demonstrated that combining baseline two-point calibration with one-point offset correction significantly improved detector uniformity and reduced image degradation caused by thermal drift."],"dc:identifier.programcode":["366, Space Systems Operations"],"dc:identifier.uri":["https://hdl.handle.net/10945/75922"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["5c0a02d8-a582-4b1a-9b41-2c1da92cb997"],"dc:relation.orgunit":["71422806-0ca0-4772-840b-075e219b82d9"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["TIC","CRIUS 1280","infrared pixel correction","nonuniformity correction","autonomous tasking","onboard autonomy","ISS thermal environment","terahertz imaging","event detection","anomaly detection"],"dc:title":["AUTONOMOUS ONBOARD CORRECTION OF INFRARED PIXEL RESPONSE FOR THE TERAHERTZ IMAGING CAMERA (TIC)"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Space Systems Operations"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Space Systems Operations"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["40529"]},"updated_at":"2026-11-19T06:44:00Z"}