{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/75958"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/75958","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"MODEL-BASED AVAILABILITY ANALYSIS OF DIGITAL TWIN IMPLEMENTATION FOR SHORE-BASED MILITARY MICROGRID SYSTEMS","abstract":"Shore-based military installations require reliable, efficient, and resilient power to sustain a posture of persistent mission readiness. Microgrid energy systems fill the gap in energy security but require increasingly complex persistent monitoring and management. Digital twin (DT) technologies provide a pathway to proactive and predictive microgrid management through bidirectional data exchange between virtual and physical systems. This thesis investigates whether implementing DT architecture can improve achieved availability of a shore-based military microgrid.A model-based systems engineering approach was employed using ExtendSim2024R1 to simulate a generic five-component microgrid across both grid connected and islanded modes of operation. Maintainability parameters were drawn from peer-reviewed literature. An integrated DT was simulated with a mean time between failure parameter modification applied as a sensitivity factor across incremental improvement values from 1% to 100%. A two-sample t-test was performed at each increment at a significance level of 0.05.Baseline achieved availability was 0.99736 for grid connected mode and 0.99577 for islanded mode. A 3% component mean time between failure (MTBF) improvement attributed to DT integration was discovered to create a statistically significant availability increase for both operating modes. The results provide a repeatable quantitative framework for translating DT requirements into required performance thresholds.","abstract_html":"Shore-based military installations require reliable, efficient, and resilient power to sustain a posture of persistent mission readiness. Microgrid energy systems fill the gap in energy security but require increasingly complex persistent monitoring and management. Digital twin (DT) technologies provide a pathway to proactive and predictive microgrid management through bidirectional data exchange between virtual and physical systems. This thesis investigates whether implementing DT architecture can improve achieved availability of a shore-based military microgrid.A model-based systems engineering approach was employed using ExtendSim2024R1 to simulate a generic five-component microgrid across both grid connected and islanded modes of operation. Maintainability parameters were drawn from peer-reviewed literature. An integrated DT was simulated with a mean time between failure parameter modification applied as a sensitivity factor across incremental improvement values from 1% to 100%. A two-sample t-test was performed at each increment at a significance level of 0.05.Baseline achieved availability was 0.99736 for grid connected mode and 0.99577 for islanded mode. A 3% component mean time between failure (MTBF) improvement attributed to DT integration was discovered to create a statistically significant availability increase for both operating modes. The results provide a repeatable quantitative framework for translating DT requirements into required performance thresholds.","abstract_has_math":false,"creators":["Romero, Justin R."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Systems Engineering","degree_level":"Masters","degree_discipline":"Systems Engineering","degree_department":"Systems Engineering (SE)","school":null,"contributors":[],"advisors":["Van Bossuyt, Douglas L."],"committee_chairs":[],"committee_members":["Wilking, Fabian"],"year":2026,"date_issued":"2026-06","date_published":"2026-06","updated_at":"2026-11-19T06:44:00Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"],"render_values":[{"text":"580, Systems Engineering","href":null,"code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["41173"],"render_values":[{"text":"41173","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/75958","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/75958","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F75958","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F75958","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Van Bossuyt, Douglas L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wilking, Fabian"]},{"key":"dc:contributor.department","label":"Department","values":["Systems Engineering (SE)"]},{"key":"dc:creator","label":"Author","values":["Romero, Justin R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-08T20:05:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-08T20:05:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["73c095de-fa3b-4d63-8300-9b6aee5b4d62"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Systems Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["41173"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["digital twin","DT","microgrid","energy security","microgrid energy system","reliability","resiliency","efficiency","virtual twin","physical twin","mean time between failure","MTBF"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["580, Systems Engineering"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/75958"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Shore-based military installations require reliable, efficient, and resilient power to sustain a posture of persistent mission readiness. Microgrid energy systems fill the gap in energy security but require increasingly complex persistent monitoring and management. Digital twin (DT) technologies provide a pathway to proactive and predictive microgrid management through bidirectional data exchange between virtual and physical systems. This thesis investigates whether implementing DT architecture can improve achieved availability of a shore-based military microgrid.A model-based systems engineering approach was employed using ExtendSim2024R1 to simulate a generic five-component microgrid across both grid connected and islanded modes of operation. Maintainability parameters were drawn from peer-reviewed literature. An integrated DT was simulated with a mean time between failure parameter modification applied as a sensitivity factor across incremental improvement values from 1% to 100%. A two-sample t-test was performed at each increment at a significance level of 0.05.Baseline achieved availability was 0.99736 for grid connected mode and 0.99577 for islanded mode. A 3% component mean time between failure (MTBF) improvement attributed to DT integration was discovered to create a statistically significant availability increase for both operating modes. The results provide a repeatable quantitative framework for translating DT requirements into required performance thresholds."]},{"key":"dc:title","label":"Title","values":["MODEL-BASED AVAILABILITY ANALYSIS OF DIGITAL TWIN IMPLEMENTATION FOR SHORE-BASED MILITARY MICROGRID SYSTEMS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Van Bossuyt, Douglas L."],"dc:contributor.committeemember":["Wilking, Fabian"],"dc:contributor.department":["Systems Engineering (SE)"],"dc:creator":["Romero, Justin R."],"dc:date.accessioned":["2026-09-08T20:05:10Z"],"dc:date.available":["2026-09-08T20:05:10Z"],"dc:date.issued":["2026-06"],"dc:description.abstract":["Shore-based military installations require reliable, efficient, and resilient power to sustain a posture of persistent mission readiness. Microgrid energy systems fill the gap in energy security but require increasingly complex persistent monitoring and management. Digital twin (DT) technologies provide a pathway to proactive and predictive microgrid management through bidirectional data exchange between virtual and physical systems. This thesis investigates whether implementing DT architecture can improve achieved availability of a shore-based military microgrid.A model-based systems engineering approach was employed using ExtendSim2024R1 to simulate a generic five-component microgrid across both grid connected and islanded modes of operation. Maintainability parameters were drawn from peer-reviewed literature. An integrated DT was simulated with a mean time between failure parameter modification applied as a sensitivity factor across incremental improvement values from 1% to 100%. A two-sample t-test was performed at each increment at a significance level of 0.05.Baseline achieved availability was 0.99736 for grid connected mode and 0.99577 for islanded mode. A 3% component mean time between failure (MTBF) improvement attributed to DT integration was discovered to create a statistically significant availability increase for both operating modes. The results provide a repeatable quantitative framework for translating DT requirements into required performance thresholds."],"dc:identifier.programcode":["580, Systems Engineering"],"dc:identifier.uri":["https://hdl.handle.net/10945/75958"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["73c095de-fa3b-4d63-8300-9b6aee5b4d62"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["digital twin","DT","microgrid","energy security","microgrid energy system","reliability","resiliency","efficiency","virtual twin","physical twin","mean time between failure","MTBF"],"dc:title":["MODEL-BASED AVAILABILITY ANALYSIS OF DIGITAL TWIN IMPLEMENTATION FOR SHORE-BASED MILITARY MICROGRID SYSTEMS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Systems Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Systems Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["41173"]},"updated_at":"2026-11-19T06:44:00Z"}