{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8028"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8028","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Bench test model of the human skull for testing the Variable Frequency Pulse Phase-Locked Loop Instrument","abstract":"The Variable Frequency Pulse Phase-Locked Loop (VFPPLL) instrument is currently being used to non-invasively evaluate the human skull for increases in intracranial distances brought about by increases in intracranial pressure. It is designed to determine distance changes, in the sub-micron range, calculated from changes in frequency of an ultrasonic toneburst produced by a transducer, traversed through the skull and received back by the transducer. A bench test model of the human skull will calibrate the VFPPLL by comparing known distance changes to the VFPPLL derived distance changes, and thereby verify the accuracy of the instrument. Additionally, the bench test model will determine a broad range of operating limits on temperature, pressure and elongation over which the VFPPLL can operate accurately. Each of the three models made demonstrates a different effect on the frequency change based on the different parameters, i.e. temperature, pressure or elongation. The Open Channel Model compares closely approximated elongations with VFPPLL derived elongations, showing favorable results for calibration of the VFPPLL instrument. Specifications for creating a bench test model of the human skull for testing the VFPPLL instrument are established in this thesis.","abstract_html":"The Variable Frequency Pulse Phase-Locked Loop (VFPPLL) instrument is currently being used to non-invasively evaluate the human skull for increases in intracranial distances brought about by increases in intracranial pressure. It is designed to determine distance changes, in the sub-micron range, calculated from changes in frequency of an ultrasonic toneburst produced by a transducer, traversed through the skull and received back by the transducer. A bench test model of the human skull will calibrate the VFPPLL by comparing known distance changes to the VFPPLL derived distance changes, and thereby verify the accuracy of the instrument. Additionally, the bench test model will determine a broad range of operating limits on temperature, pressure and elongation over which the VFPPLL can operate accurately. Each of the three models made demonstrates a different effect on the frequency change based on the different parameters, i.e. temperature, pressure or elongation. The Open Channel Model compares closely approximated elongations with VFPPLL derived elongations, showing favorable results for calibration of the VFPPLL instrument. Specifications for creating a bench test model of the human skull for testing the VFPPLL instrument are established in this thesis.","abstract_has_math":false,"creators":["Burin, Amy Diana"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Astronautical Engineering","degree_level":"Masters","degree_discipline":"Astronautical Engineering","degree_department":"Department of Aeronautics and Astronautics","school":null,"contributors":[],"advisors":["Scrivener, Sandra L."],"committee_chairs":[],"committee_members":["Panholzer, Rudolf"],"year":1996,"date_issued":"1996-12","date_published":"1996-12","updated_at":"2026-11-21T23:44:27Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8028","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8028","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8028","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Scrivener, Sandra L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Panholzer, Rudolf"]},{"key":"dc:contributor.department","label":"Department","values":["Department of Aeronautics and Astronautics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Burin, Amy Diana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1996"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:18:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:18:16Z"]},{"key":"dc:date.issued","label":"Date","values":["1996-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Astronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Human skull model","pulse phase-locked loop","intracranial pressure","intracranial distance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8028"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Variable Frequency Pulse Phase-Locked Loop (VFPPLL) instrument is currently being used to non-invasively evaluate the human skull for increases in intracranial distances brought about by increases in intracranial pressure. It is designed to determine distance changes, in the sub-micron range, calculated from changes in frequency of an ultrasonic toneburst produced by a transducer, traversed through the skull and received back by the transducer. A bench test model of the human skull will calibrate the VFPPLL by comparing known distance changes to the VFPPLL derived distance changes, and thereby verify the accuracy of the instrument. Additionally, the bench test model will determine a broad range of operating limits on temperature, pressure and elongation over which the VFPPLL can operate accurately. Each of the three models made demonstrates a different effect on the frequency change based on the different parameters, i.e. temperature, pressure or elongation. The Open Channel Model compares closely approximated elongations with VFPPLL derived elongations, showing favorable results for calibration of the VFPPLL instrument. Specifications for creating a bench test model of the human skull for testing the VFPPLL instrument are established in this thesis."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/benchtestmodelof109458028"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xviii, 118 p."]},{"key":"dc:title","label":"Title","values":["Bench test model of the human skull for testing the Variable Frequency Pulse Phase-Locked Loop Instrument"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Scrivener, Sandra L."],"dc:contributor.committeemember":["Panholzer, Rudolf"],"dc:contributor.department":["Department of Aeronautics and Astronautics"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Burin, Amy Diana"],"dc:date":["December 1996"],"dc:date.accessioned":["2012-08-09T19:18:16Z"],"dc:date.available":["2012-08-09T19:18:16Z"],"dc:date.issued":["1996-12"],"dc:description.abstract":["The Variable Frequency Pulse Phase-Locked Loop (VFPPLL) instrument is currently being used to non-invasively evaluate the human skull for increases in intracranial distances brought about by increases in intracranial pressure. It is designed to determine distance changes, in the sub-micron range, calculated from changes in frequency of an ultrasonic toneburst produced by a transducer, traversed through the skull and received back by the transducer. A bench test model of the human skull will calibrate the VFPPLL by comparing known distance changes to the VFPPLL derived distance changes, and thereby verify the accuracy of the instrument. Additionally, the bench test model will determine a broad range of operating limits on temperature, pressure and elongation over which the VFPPLL can operate accurately. Each of the three models made demonstrates a different effect on the frequency change based on the different parameters, i.e. temperature, pressure or elongation. The Open Channel Model compares closely approximated elongations with VFPPLL derived elongations, showing favorable results for calibration of the VFPPLL instrument. Specifications for creating a bench test model of the human skull for testing the VFPPLL instrument are established in this thesis."],"dc:description.uri":["http://archive.org/details/benchtestmodelof109458028"],"dc:format.extent":["xviii, 118 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/8028"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Human skull model","pulse phase-locked loop","intracranial pressure","intracranial distance"],"dc:title":["Bench test model of the human skull for testing the Variable Frequency Pulse Phase-Locked Loop Instrument"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Astronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Astronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:44:27Z"}