{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8255"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8255","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Development of a control system for a SMA actuated medical manipulator","abstract":"This thesis discusses the development of a digital control system for the operation of a conceptual robotic manipulator for use in minimally invasive surgery. The motion of the manipulator is envisioned to be accomplished with actuators made of Shape Memory Alloy (SMA). SMA has the ability to recover permanent deformation by undergoing a phase transformation. The recovery of the deformation results in motion of the SMA material which can be exploited for useful work. SMA was chosen as the actuator because it can be miniaturized and has a very high power density as compared to conventional actuators. An Actuator Matrix Driver (AMD) board was designed, as part of the digital control system, to power and control the SMA actuators. The matrix configuration of the AMD and the use of Amplitude Modulated Pulsed (AMP) current allows for a reduction in the number of leads for the powering and control of the actuators. The electrical resistance, a physical property of SMA which characteristically changes with phase transformation, can be used to determine the state or phase of the SMA actuators and can therefore be used for closed loop control","abstract_html":"This thesis discusses the development of a digital control system for the operation of a conceptual robotic manipulator for use in minimally invasive surgery. The motion of the manipulator is envisioned to be accomplished with actuators made of Shape Memory Alloy (SMA). SMA has the ability to recover permanent deformation by undergoing a phase transformation. The recovery of the deformation results in motion of the SMA material which can be exploited for useful work. SMA was chosen as the actuator because it can be miniaturized and has a very high power density as compared to conventional actuators. An Actuator Matrix Driver (AMD) board was designed, as part of the digital control system, to power and control the SMA actuators. The matrix configuration of the AMD and the use of Amplitude Modulated Pulsed (AMP) current allows for a reduction in the number of leads for the powering and control of the actuators. The electrical resistance, a physical property of SMA which characteristically changes with phase transformation, can be used to determine the state or phase of the SMA actuators and can therefore be used for closed loop control","abstract_has_math":false,"creators":["Thiel, Richard A"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Mukherjee, Ranjan"],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997-12","date_published":"1997-12","updated_at":"2026-11-24T23:47:28Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8255","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8255","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8255","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mukherjee, Ranjan"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Thiel, Richard A"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:19:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:19:42Z"]},{"key":"dc:date.issued","label":"Date","values":["1997-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Shape Memory Alloy (SMA)","Actuator Matrix Driver (AMD) Board","Amplitude Modulated Pulsed (AMP) Current"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8255"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis discusses the development of a digital control system for the operation of a conceptual robotic manipulator for use in minimally invasive surgery. The motion of the manipulator is envisioned to be accomplished with actuators made of Shape Memory Alloy (SMA). SMA has the ability to recover permanent deformation by undergoing a phase transformation. The recovery of the deformation results in motion of the SMA material which can be exploited for useful work. SMA was chosen as the actuator because it can be miniaturized and has a very high power density as compared to conventional actuators. An Actuator Matrix Driver (AMD) board was designed, as part of the digital control system, to power and control the SMA actuators. The matrix configuration of the AMD and the use of Amplitude Modulated Pulsed (AMP) current allows for a reduction in the number of leads for the powering and control of the actuators. The electrical resistance, a physical property of SMA which characteristically changes with phase transformation, can be used to determine the state or phase of the SMA actuators and can therefore be used for closed loop control"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/developmentofcon109458255"]},{"key":"dc:title","label":"Title","values":["Development of a control system for a SMA actuated medical manipulator"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mukherjee, Ranjan"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Thiel, Richard A"],"dc:date.accessioned":["2012-08-09T19:19:42Z"],"dc:date.available":["2012-08-09T19:19:42Z"],"dc:date.issued":["1997-12"],"dc:description.abstract":["This thesis discusses the development of a digital control system for the operation of a conceptual robotic manipulator for use in minimally invasive surgery. The motion of the manipulator is envisioned to be accomplished with actuators made of Shape Memory Alloy (SMA). SMA has the ability to recover permanent deformation by undergoing a phase transformation. The recovery of the deformation results in motion of the SMA material which can be exploited for useful work. SMA was chosen as the actuator because it can be miniaturized and has a very high power density as compared to conventional actuators. An Actuator Matrix Driver (AMD) board was designed, as part of the digital control system, to power and control the SMA actuators. The matrix configuration of the AMD and the use of Amplitude Modulated Pulsed (AMP) current allows for a reduction in the number of leads for the powering and control of the actuators. The electrical resistance, a physical property of SMA which characteristically changes with phase transformation, can be used to determine the state or phase of the SMA actuators and can therefore be used for closed loop control"],"dc:description.uri":["http://archive.org/details/developmentofcon109458255"],"dc:identifier.uri":["https://hdl.handle.net/10945/8255"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:subject.keyword":["Shape Memory Alloy (SMA)","Actuator Matrix Driver (AMD) Board","Amplitude Modulated Pulsed (AMP) Current"],"dc:title":["Development of a control system for a SMA actuated medical manipulator"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-24T23:47:28Z"}