{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8437"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8437","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Fusion neutron damage to a charge coupled device camera","abstract":"A charge coupled device (CCD) camera's performance has been degraded by damage produced by 14 MeV neutrons (n) from the Rotating Target Neutron Source. High energy neutrons produce atomic dislocation in doped silicon electronics. This thesis explores changes in Dark Current (J), Charge Transfer Inefficiency (CTI), and Contrast Transfer Function (CTF) as measures of neutron damage. The camera was irradiated to a fluence, Phi, of 6.60 x 10 (exp 12) n/ cm2. The camera temperature was lowered from room temperature to 267 K at a fluence of 4.7 x 10 (exp 11) n/cm2 to preclude saturation of the camera picture. With temperature compensations, J increased linearly with Phi. Four data points for J, CTF (ideal of 1.0), and CTI (ideal of 0.0) are given. Neutron irradiation significantly degraded the CCD camera performance; however, operating the camera at lower temperatures significantly reduces the effects. Damage thresholds for fluences greater than 6.60 x 10 (exp 12) n/cm2 and for all temperatures can be extrapolated from the results of this work","abstract_html":"A charge coupled device (CCD) camera&#x27;s performance has been degraded by damage produced by 14 MeV neutrons (n) from the Rotating Target Neutron Source. High energy neutrons produce atomic dislocation in doped silicon electronics. This thesis explores changes in Dark Current (J), Charge Transfer Inefficiency (CTI), and Contrast Transfer Function (CTF) as measures of neutron damage. The camera was irradiated to a fluence, Phi, of 6.60 x 10 (exp 12) n/ cm2. The camera temperature was lowered from room temperature to 267 K at a fluence of 4.7 x 10 (exp 11) n/cm2 to preclude saturation of the camera picture. With temperature compensations, J increased linearly with Phi. Four data points for J, CTF (ideal of 1.0), and CTI (ideal of 0.0) are given. Neutron irradiation significantly degraded the CCD camera performance; however, operating the camera at lower temperatures significantly reduces the effects. Damage thresholds for fluences greater than 6.60 x 10 (exp 12) n/cm2 and for all temperatures can be extrapolated from the results of this work","abstract_has_math":false,"creators":["Amaden, Christopher Dean"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Maier, William B. II","Maruyama, Xavier K."],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997-09","date_published":"1997-09","updated_at":"2026-11-20T22:10:12Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8437","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8437","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8437","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Maier, William B. II","Maruyama, Xavier K."]},{"key":"dc:creator","label":"Author","values":["Amaden, Christopher Dean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:20:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:20:50Z"]},{"key":"dc:date.issued","label":"Date","values":["1997-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Neutron Radiation","Charge Coupled Device","Dark Current","Contrast Transfer Function","Charge Transfer Inefficiency"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8437"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A charge coupled device (CCD) camera's performance has been degraded by damage produced by 14 MeV neutrons (n) from the Rotating Target Neutron Source. High energy neutrons produce atomic dislocation in doped silicon electronics. This thesis explores changes in Dark Current (J), Charge Transfer Inefficiency (CTI), and Contrast Transfer Function (CTF) as measures of neutron damage. The camera was irradiated to a fluence, Phi, of 6.60 x 10 (exp 12) n/ cm2. The camera temperature was lowered from room temperature to 267 K at a fluence of 4.7 x 10 (exp 11) n/cm2 to preclude saturation of the camera picture. With temperature compensations, J increased linearly with Phi. Four data points for J, CTF (ideal of 1.0), and CTI (ideal of 0.0) are given. Neutron irradiation significantly degraded the CCD camera performance; however, operating the camera at lower temperatures significantly reduces the effects. Damage thresholds for fluences greater than 6.60 x 10 (exp 12) n/cm2 and for all temperatures can be extrapolated from the results of this work"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/fusionneutrondam109458437"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xi, 40 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Fusion neutron damage to a charge coupled device camera"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Maier, William B. II","Maruyama, Xavier K."],"dc:creator":["Amaden, Christopher Dean"],"dc:date.accessioned":["2012-08-09T19:20:50Z"],"dc:date.available":["2012-08-09T19:20:50Z"],"dc:date.issued":["1997-09"],"dc:description.abstract":["A charge coupled device (CCD) camera's performance has been degraded by damage produced by 14 MeV neutrons (n) from the Rotating Target Neutron Source. High energy neutrons produce atomic dislocation in doped silicon electronics. This thesis explores changes in Dark Current (J), Charge Transfer Inefficiency (CTI), and Contrast Transfer Function (CTF) as measures of neutron damage. The camera was irradiated to a fluence, Phi, of 6.60 x 10 (exp 12) n/ cm2. The camera temperature was lowered from room temperature to 267 K at a fluence of 4.7 x 10 (exp 11) n/cm2 to preclude saturation of the camera picture. With temperature compensations, J increased linearly with Phi. Four data points for J, CTF (ideal of 1.0), and CTI (ideal of 0.0) are given. Neutron irradiation significantly degraded the CCD camera performance; however, operating the camera at lower temperatures significantly reduces the effects. Damage thresholds for fluences greater than 6.60 x 10 (exp 12) n/cm2 and for all temperatures can be extrapolated from the results of this work"],"dc:description.uri":["http://archive.org/details/fusionneutrondam109458437"],"dc:format.extent":["xi, 40 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/8437"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Neutron Radiation","Charge Coupled Device","Dark Current","Contrast Transfer Function","Charge Transfer Inefficiency"],"dc:title":["Fusion neutron damage to a charge coupled device camera"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:10:12Z"}