{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8438"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8438","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Fusion neutron transient effects to charge coupled device camera images","abstract":"A charge coupled device (CCD) camera's images were degraded by neutron-induced blemishes, called stars, while being irradiated with 14 MeV neutrons (n) from the Rotating Target Neutron Source. This thesis analyzed simulated images for a CCD camera operating during neutron irradiation. The simulated images were created to provide data to help determine how much shielding a CCD camera would require while being used a diagnostic tool during inertial fusion events at the National Ignition Facility. The simulated images were created from data obtained at the Rotating Target Neutron Source. The Contrast Transfer Function (CTF), autocorrelation function and visual comparisons were used as measures of the transient effects of the neutron irradiation on the simulated images. The CTF and visual image quality started to degrade significantly at neutron fluences around 10(exp 8) n/sq cm. The autocorrelation function determined that the average size of neutron-induced star was 4 x 4 pixels. Increasing neutron fluence produced image changes that could be explained by a variation in sensitivity across the camera face or (more likely) by increased Charge Transfer Inefficiency (CTI) with increasing charge loading of the CCD.","abstract_html":"A charge coupled device (CCD) camera&#x27;s images were degraded by neutron-induced blemishes, called stars, while being irradiated with 14 MeV neutrons (n) from the Rotating Target Neutron Source. This thesis analyzed simulated images for a CCD camera operating during neutron irradiation. The simulated images were created to provide data to help determine how much shielding a CCD camera would require while being used a diagnostic tool during inertial fusion events at the National Ignition Facility. The simulated images were created from data obtained at the Rotating Target Neutron Source. The Contrast Transfer Function (CTF), autocorrelation function and visual comparisons were used as measures of the transient effects of the neutron irradiation on the simulated images. The CTF and visual image quality started to degrade significantly at neutron fluences around 10(exp 8) n/sq cm. The autocorrelation function determined that the average size of neutron-induced star was 4 x 4 pixels. Increasing neutron fluence produced image changes that could be explained by a variation in sensitivity across the camera face or (more likely) by increased Charge Transfer Inefficiency (CTI) with increasing charge loading of the CCD.","abstract_has_math":false,"creators":["Giauque, Michael S."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Maier, William B., II","Davis, D. Scott"],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999-06-01","date_published":"1999-06-01","updated_at":"2026-11-21T22:23:57Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8438","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8438","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F8438","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8438","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Maier, William B., II","Davis, D. Scott"]},{"key":"dc:contributor.department","label":"Department","values":["Department of Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Giauque, Michael S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1999"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:20:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:20:50Z"]},{"key":"dc:date.issued","label":"Date","values":["1999-06-01"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Neutron irradiation","Charge coupled device camera","Contrast transfer function"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8438"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A charge coupled device (CCD) camera's images were degraded by neutron-induced blemishes, called stars, while being irradiated with 14 MeV neutrons (n) from the Rotating Target Neutron Source. This thesis analyzed simulated images for a CCD camera operating during neutron irradiation. The simulated images were created to provide data to help determine how much shielding a CCD camera would require while being used a diagnostic tool during inertial fusion events at the National Ignition Facility. The simulated images were created from data obtained at the Rotating Target Neutron Source. The Contrast Transfer Function (CTF), autocorrelation function and visual comparisons were used as measures of the transient effects of the neutron irradiation on the simulated images. The CTF and visual image quality started to degrade significantly at neutron fluences around 10(exp 8) n/sq cm. The autocorrelation function determined that the average size of neutron-induced star was 4 x 4 pixels. Increasing neutron fluence produced image changes that could be explained by a variation in sensitivity across the camera face or (more likely) by increased Charge Transfer Inefficiency (CTI) with increasing charge loading of the CCD."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/fusionneutrontra109458438"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xi, 45 p."]},{"key":"dc:title","label":"Title","values":["Fusion neutron transient effects to charge coupled device camera images"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Maier, William B., II","Davis, D. Scott"],"dc:contributor.department":["Department of Physics"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Giauque, Michael S."],"dc:date":["June 1999"],"dc:date.accessioned":["2012-08-09T19:20:50Z"],"dc:date.available":["2012-08-09T19:20:50Z"],"dc:date.issued":["1999-06-01"],"dc:description.abstract":["A charge coupled device (CCD) camera's images were degraded by neutron-induced blemishes, called stars, while being irradiated with 14 MeV neutrons (n) from the Rotating Target Neutron Source. This thesis analyzed simulated images for a CCD camera operating during neutron irradiation. The simulated images were created to provide data to help determine how much shielding a CCD camera would require while being used a diagnostic tool during inertial fusion events at the National Ignition Facility. The simulated images were created from data obtained at the Rotating Target Neutron Source. The Contrast Transfer Function (CTF), autocorrelation function and visual comparisons were used as measures of the transient effects of the neutron irradiation on the simulated images. The CTF and visual image quality started to degrade significantly at neutron fluences around 10(exp 8) n/sq cm. The autocorrelation function determined that the average size of neutron-induced star was 4 x 4 pixels. Increasing neutron fluence produced image changes that could be explained by a variation in sensitivity across the camera face or (more likely) by increased Charge Transfer Inefficiency (CTI) with increasing charge loading of the CCD."],"dc:description.uri":["http://archive.org/details/fusionneutrontra109458438"],"dc:format.extent":["xi, 45 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/8438"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Neutron irradiation","Charge coupled device camera","Contrast transfer function"],"dc:title":["Fusion neutron transient effects to charge coupled device camera images"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:23:57Z"}