{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8537"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8537","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Instantaneous axis of rotation for continuous human knee motion","abstract":"Previous studies of human knee motion are based on finite rotation data collected using large rotation steps varying from 5 to 30 degrees. In some cases this rotation data is used to develop axes of rotation for the joint. For such analysis, the rotation axis developed may be significantly different from the joint's instantaneous axis of rotation because, in general, the axis of rotation developed using finite rotation steps only closely approximates the true instantaneous axis of rotation if the step size is small. For the current study, a device has been developed to record high frequency (15 Hz) rotation and translation data of the femur and tibia during knee flexion. Kinematic constraint equations have been developed to analyze the six degree of freedom rotation and translation data to obtain an accurate approximation to the instantaneous axis of rotation. Four cadaveric knees were II analyzed with all ligaments intact. Motion characteristics common to all knees were identified. The most obvious characteristic, internal tibial rotation, was related to the initial varus/valgus orientation of each knee. The anterior cruciate ligaments (ACL) of these same knees were subsequently severed, the knees were measured, and the motion analyzed. Differences in the motion characteristics of each knee were detected alter the ACL was cut","abstract_html":"Previous studies of human knee motion are based on finite rotation data collected using large rotation steps varying from 5 to 30 degrees. In some cases this rotation data is used to develop axes of rotation for the joint. For such analysis, the rotation axis developed may be significantly different from the joint&#x27;s instantaneous axis of rotation because, in general, the axis of rotation developed using finite rotation steps only closely approximates the true instantaneous axis of rotation if the step size is small. For the current study, a device has been developed to record high frequency (15 Hz) rotation and translation data of the femur and tibia during knee flexion. Kinematic constraint equations have been developed to analyze the six degree of freedom rotation and translation data to obtain an accurate approximation to the instantaneous axis of rotation. Four cadaveric knees were II analyzed with all ligaments intact. Motion characteristics common to all knees were identified. The most obvious characteristic, internal tibial rotation, was related to the initial varus/valgus orientation of each knee. The anterior cruciate ligaments (ACL) of these same knees were subsequently severed, the knees were measured, and the motion analyzed. Differences in the motion characteristics of each knee were detected alter the ACL was cut","abstract_has_math":false,"creators":["Parks, Steven A."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Kwon, Young W."],"committee_chairs":[],"committee_members":["Demaio, Marlene"],"year":1997,"date_issued":"1997-06","date_published":"1997-06","updated_at":"2026-11-19T06:44:33Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8537","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8537","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8537","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kwon, Young W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Demaio, Marlene"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Parks, Steven A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:21:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:21:25Z"]},{"key":"dc:date.issued","label":"Date","values":["1997-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Biometrics","Three Dimensional Rigid Body Motion","Knee Joint","Continuous Motion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8537"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Previous studies of human knee motion are based on finite rotation data collected using large rotation steps varying from 5 to 30 degrees. In some cases this rotation data is used to develop axes of rotation for the joint. For such analysis, the rotation axis developed may be significantly different from the joint's instantaneous axis of rotation because, in general, the axis of rotation developed using finite rotation steps only closely approximates the true instantaneous axis of rotation if the step size is small. For the current study, a device has been developed to record high frequency (15 Hz) rotation and translation data of the femur and tibia during knee flexion. Kinematic constraint equations have been developed to analyze the six degree of freedom rotation and translation data to obtain an accurate approximation to the instantaneous axis of rotation. Four cadaveric knees were II analyzed with all ligaments intact. Motion characteristics common to all knees were identified. The most obvious characteristic, internal tibial rotation, was related to the initial varus/valgus orientation of each knee. The anterior cruciate ligaments (ACL) of these same knees were subsequently severed, the knees were measured, and the motion analyzed. Differences in the motion characteristics of each knee were detected alter the ACL was cut"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/instantaneousxis109458537"]},{"key":"dc:title","label":"Title","values":["Instantaneous axis of rotation for continuous human knee motion"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kwon, Young W."],"dc:contributor.committeemember":["Demaio, Marlene"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Parks, Steven A."],"dc:date.accessioned":["2012-08-09T19:21:25Z"],"dc:date.available":["2012-08-09T19:21:25Z"],"dc:date.issued":["1997-06"],"dc:description.abstract":["Previous studies of human knee motion are based on finite rotation data collected using large rotation steps varying from 5 to 30 degrees. In some cases this rotation data is used to develop axes of rotation for the joint. For such analysis, the rotation axis developed may be significantly different from the joint's instantaneous axis of rotation because, in general, the axis of rotation developed using finite rotation steps only closely approximates the true instantaneous axis of rotation if the step size is small. For the current study, a device has been developed to record high frequency (15 Hz) rotation and translation data of the femur and tibia during knee flexion. Kinematic constraint equations have been developed to analyze the six degree of freedom rotation and translation data to obtain an accurate approximation to the instantaneous axis of rotation. Four cadaveric knees were II analyzed with all ligaments intact. Motion characteristics common to all knees were identified. The most obvious characteristic, internal tibial rotation, was related to the initial varus/valgus orientation of each knee. The anterior cruciate ligaments (ACL) of these same knees were subsequently severed, the knees were measured, and the motion analyzed. Differences in the motion characteristics of each knee were detected alter the ACL was cut"],"dc:description.uri":["http://archive.org/details/instantaneousxis109458537"],"dc:identifier.uri":["https://hdl.handle.net/10945/8537"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Biometrics","Three Dimensional Rigid Body Motion","Knee Joint","Continuous Motion"],"dc:title":["Instantaneous axis of rotation for continuous human knee motion"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:44:33Z"}