{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8773"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8773","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Operation and calibration of the NPS Ultraviolet Imaging Spectrometer (NUVIS) in the detection of sulfur dioxide plumes","abstract":"The Naval Postgraduate School's Ultraviolet Imaging Spectrometer (NUVIS) is a hyperspectral sensor with a spectral response of 300 to 375 nanometers. This thesis research concentrates on the operation and calibration of NUVIS in the detection of effluent suliur dioxide (SO2) plumes. NUVIS is capable of detecting and quantifying SO2 emissions in the form of effluent smokestack plumes by exploiting SO2's unique Uv absorption signature. Laboratory comparison UV spectra of 502 were recorded and used to calculate curves of growth for four different 502 spectral features. Laboratory results were employed to analyze field data taken of a coal-burning power plant. Analysis of this plume data yielded a mean plume SO2 mixing ratio of 365 i 200 ppm, in agreement with the in situ stack value of 400 ppm. Further assessment of NUVIS indicates that its lower limit for SO2 detection in typical field applications is approximately 70 ppm","abstract_html":"The Naval Postgraduate School&#x27;s Ultraviolet Imaging Spectrometer (NUVIS) is a hyperspectral sensor with a spectral response of 300 to 375 nanometers. This thesis research concentrates on the operation and calibration of NUVIS in the detection of effluent suliur dioxide (SO2) plumes. NUVIS is capable of detecting and quantifying SO2 emissions in the form of effluent smokestack plumes by exploiting SO2&#x27;s unique Uv absorption signature. Laboratory comparison UV spectra of 502 were recorded and used to calculate curves of growth for four different 502 spectral features. Laboratory results were employed to analyze field data taken of a coal-burning power plant. Analysis of this plume data yielded a mean plume SO2 mixing ratio of 365 i 200 ppm, in agreement with the in situ stack value of 400 ppm. Further assessment of NUVIS indicates that its lower limit for SO2 detection in typical field applications is approximately 70 ppm","abstract_has_math":false,"creators":["Marino, Stephen A."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Davis, David S.","Olsen, Richard C."],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999-12","date_published":"1999-12","updated_at":"2026-11-20T22:07:25Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8773","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8773","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8773","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Davis, David S.","Olsen, Richard C."]},{"key":"dc:creator","label":"Author","values":["Marino, Stephen A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:22:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:22:43Z"]},{"key":"dc:date.issued","label":"Date","values":["1999-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Ultraviolet","Hyperspectral","Spectral Imaging","Spectrometer","Sulfur Dioxide","Pollution","Remote Sensing","Environmental Monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8773"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Naval Postgraduate School's Ultraviolet Imaging Spectrometer (NUVIS) is a hyperspectral sensor with a spectral response of 300 to 375 nanometers. This thesis research concentrates on the operation and calibration of NUVIS in the detection of effluent suliur dioxide (SO2) plumes. NUVIS is capable of detecting and quantifying SO2 emissions in the form of effluent smokestack plumes by exploiting SO2's unique Uv absorption signature. Laboratory comparison UV spectra of 502 were recorded and used to calculate curves of growth for four different 502 spectral features. Laboratory results were employed to analyze field data taken of a coal-burning power plant. Analysis of this plume data yielded a mean plume SO2 mixing ratio of 365 i 200 ppm, in agreement with the in situ stack value of 400 ppm. Further assessment of NUVIS indicates that its lower limit for SO2 detection in typical field applications is approximately 70 ppm"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/operationndcalib109458773"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 94 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Operation and calibration of the NPS Ultraviolet Imaging Spectrometer (NUVIS) in the detection of sulfur dioxide plumes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Davis, David S.","Olsen, Richard C."],"dc:creator":["Marino, Stephen A."],"dc:date.accessioned":["2012-08-09T19:22:43Z"],"dc:date.available":["2012-08-09T19:22:43Z"],"dc:date.issued":["1999-12"],"dc:description.abstract":["The Naval Postgraduate School's Ultraviolet Imaging Spectrometer (NUVIS) is a hyperspectral sensor with a spectral response of 300 to 375 nanometers. This thesis research concentrates on the operation and calibration of NUVIS in the detection of effluent suliur dioxide (SO2) plumes. NUVIS is capable of detecting and quantifying SO2 emissions in the form of effluent smokestack plumes by exploiting SO2's unique Uv absorption signature. Laboratory comparison UV spectra of 502 were recorded and used to calculate curves of growth for four different 502 spectral features. Laboratory results were employed to analyze field data taken of a coal-burning power plant. Analysis of this plume data yielded a mean plume SO2 mixing ratio of 365 i 200 ppm, in agreement with the in situ stack value of 400 ppm. Further assessment of NUVIS indicates that its lower limit for SO2 detection in typical field applications is approximately 70 ppm"],"dc:description.uri":["http://archive.org/details/operationndcalib109458773"],"dc:format.extent":["ix, 94 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/8773"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Ultraviolet","Hyperspectral","Spectral Imaging","Spectrometer","Sulfur Dioxide","Pollution","Remote Sensing","Environmental Monitoring"],"dc:title":["Operation and calibration of the NPS Ultraviolet Imaging Spectrometer (NUVIS) in the detection of sulfur dioxide plumes"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:07:25Z"}