{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8802"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8802","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Parametric x-radiation from mosaic graphite: new results and reconciliation of previous experiments","abstract":"This thesis explores the effects of mosaic graphite on the yield of parametric x-radiation (PXR). PXR is the Bragg scattering of virtual photons associated with the Coulombic field of relativistically charged particles interacting with the atomic planes of a crystal. PXR was measured from three samples of mosaic graphite crystals with differing mosaicities. The number of photons per electron was calibrated with the fluorescent x-ray yield from a thin silver foil backing on each of the mosaic crystals. The detector angular field of view was narrowed from previous experiments. Improvements were made in the re-analysis of previous experiments by considering the thick target effects of the x-ray absorption. Previous experiments had erroneously assumed that the calibration fluorescent targets were thin. Re-analysis of previous data using corrections for solid angle, crystal absorption factors and effective thickness resulted in yields similar to those obtained in this work.","abstract_html":"This thesis explores the effects of mosaic graphite on the yield of parametric x-radiation (PXR). PXR is the Bragg scattering of virtual photons associated with the Coulombic field of relativistically charged particles interacting with the atomic planes of a crystal. PXR was measured from three samples of mosaic graphite crystals with differing mosaicities. The number of photons per electron was calibrated with the fluorescent x-ray yield from a thin silver foil backing on each of the mosaic crystals. The detector angular field of view was narrowed from previous experiments. Improvements were made in the re-analysis of previous experiments by considering the thick target effects of the x-ray absorption. Previous experiments had erroneously assumed that the calibration fluorescent targets were thin. Re-analysis of previous data using corrections for solid angle, crystal absorption factors and effective thickness resulted in yields similar to those obtained in this work.","abstract_has_math":false,"creators":["Barrows, James E."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Maruyama, Xavier K."],"committee_chairs":[],"committee_members":["Harkins, Richard M."],"year":1996,"date_issued":"1996-03","date_published":"1996-03","updated_at":"2026-11-21T23:24:54Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8802","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8802","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8802","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Maruyama, Xavier K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Harkins, Richard M."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Barrows, James E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1996"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:22:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:22:51Z"]},{"key":"dc:date.issued","label":"Date","values":["1996-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["parametric x-radiation","mosaic spread","absorption factors"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8802"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis explores the effects of mosaic graphite on the yield of parametric x-radiation (PXR). PXR is the Bragg scattering of virtual photons associated with the Coulombic field of relativistically charged particles interacting with the atomic planes of a crystal. PXR was measured from three samples of mosaic graphite crystals with differing mosaicities. The number of photons per electron was calibrated with the fluorescent x-ray yield from a thin silver foil backing on each of the mosaic crystals. The detector angular field of view was narrowed from previous experiments. Improvements were made in the re-analysis of previous experiments by considering the thick target effects of the x-ray absorption. Previous experiments had erroneously assumed that the calibration fluorescent targets were thin. Re-analysis of previous data using corrections for solid angle, crystal absorption factors and effective thickness resulted in yields similar to those obtained in this work."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/parametricxradia109458802"]},{"key":"dc:title","label":"Title","values":["Parametric x-radiation from mosaic graphite: new results and reconciliation of previous experiments"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Maruyama, Xavier K."],"dc:contributor.committeemember":["Harkins, Richard M."],"dc:contributor.department":["Department of Physics"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Barrows, James E."],"dc:date":["March 1996"],"dc:date.accessioned":["2012-08-09T19:22:51Z"],"dc:date.available":["2012-08-09T19:22:51Z"],"dc:date.issued":["1996-03"],"dc:description.abstract":["This thesis explores the effects of mosaic graphite on the yield of parametric x-radiation (PXR). PXR is the Bragg scattering of virtual photons associated with the Coulombic field of relativistically charged particles interacting with the atomic planes of a crystal. PXR was measured from three samples of mosaic graphite crystals with differing mosaicities. The number of photons per electron was calibrated with the fluorescent x-ray yield from a thin silver foil backing on each of the mosaic crystals. The detector angular field of view was narrowed from previous experiments. Improvements were made in the re-analysis of previous experiments by considering the thick target effects of the x-ray absorption. Previous experiments had erroneously assumed that the calibration fluorescent targets were thin. Re-analysis of previous data using corrections for solid angle, crystal absorption factors and effective thickness resulted in yields similar to those obtained in this work."],"dc:description.uri":["http://archive.org/details/parametricxradia109458802"],"dc:identifier.uri":["https://hdl.handle.net/10945/8802"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["parametric x-radiation","mosaic spread","absorption factors"],"dc:title":["Parametric x-radiation from mosaic graphite: new results and reconciliation of previous experiments"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:24:54Z"}