{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/8828"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/8828","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Polarization effects on infrared target contrast","abstract":"An analysis has been carried out of a data base of polarized long wave infrared images of the instrumented Research Vessel POINT SUR recorded over a period of two days during the EOPACE measurements series in San Diego Bay in 1996. The measurements were made from a land site on Point Loma with an AGA780 sensor with internally mounted polarization filters. The objectives of the analysis were to determine a possible influence of target aspect angle on the polarization signature, to compare polarization contrast improvement in San Diego Bay with previous measurements in the North Atlantic, and to validate by measurement the estimation of unpolarized signature from vertical and horizontal components. 5508 images representing 70 cases with vertical, horizontal and unpolarized sequences were analyzed. Using a horizontal polarizer, target to background contrast improvement was found with a mean of 1.08 (8%) compared with the 15% found in previous measurements. Estimated unpolarized signatures from vertical and horizontal components agreed with unpolarized measurements with a slope coefficient of .85 to .99. Target signature for major ship facets and for total ship showed no discernable degree of polarization. A total of 37 IDL programs developed for this analysis can be assembled as a package for future data processing","abstract_html":"An analysis has been carried out of a data base of polarized long wave infrared images of the instrumented Research Vessel POINT SUR recorded over a period of two days during the EOPACE measurements series in San Diego Bay in 1996. The measurements were made from a land site on Point Loma with an AGA780 sensor with internally mounted polarization filters. The objectives of the analysis were to determine a possible influence of target aspect angle on the polarization signature, to compare polarization contrast improvement in San Diego Bay with previous measurements in the North Atlantic, and to validate by measurement the estimation of unpolarized signature from vertical and horizontal components. 5508 images representing 70 cases with vertical, horizontal and unpolarized sequences were analyzed. Using a horizontal polarizer, target to background contrast improvement was found with a mean of 1.08 (8%) compared with the 15% found in previous measurements. Estimated unpolarized signatures from vertical and horizontal components agreed with unpolarized measurements with a slope coefficient of .85 to .99. Target signature for major ship facets and for total ship showed no discernable degree of polarization. A total of 37 IDL programs developed for this analysis can be assembled as a package for future data processing","abstract_has_math":false,"creators":["Pontes, Marcos Cesar"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Systems Engineering","degree_level":"Masters","degree_discipline":"Systems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Cleary, David D.","Cooper, Alfred W."],"committee_chairs":[],"committee_members":[],"year":1998,"date_issued":"1998-09","date_published":"1998-09","updated_at":"2026-11-19T06:44:33Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["596 (Electronic Warfare Systems (International)"],"render_values":[{"text":"596 (Electronic Warfare Systems (International)","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/8828","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/8828","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F8828","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F8828","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cleary, David D.","Cooper, Alfred W."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Information Warfare Academic Group"]},{"key":"dc:creator","label":"Author","values":["Pontes, Marcos Cesar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:22:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:22:59Z"]},{"key":"dc:date.issued","label":"Date","values":["1998-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["3ca085ea-3ce5-45da-9273-fe2cbe728c6d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Systems Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Thermal Imaging","Polarization","Target Contrast","Infrared Radiation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.programcode","label":"Dc Identifier Programcode","values":["596 (Electronic Warfare Systems (International)"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/8828"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An analysis has been carried out of a data base of polarized long wave infrared images of the instrumented Research Vessel POINT SUR recorded over a period of two days during the EOPACE measurements series in San Diego Bay in 1996. The measurements were made from a land site on Point Loma with an AGA780 sensor with internally mounted polarization filters. The objectives of the analysis were to determine a possible influence of target aspect angle on the polarization signature, to compare polarization contrast improvement in San Diego Bay with previous measurements in the North Atlantic, and to validate by measurement the estimation of unpolarized signature from vertical and horizontal components. 5508 images representing 70 cases with vertical, horizontal and unpolarized sequences were analyzed. Using a horizontal polarizer, target to background contrast improvement was found with a mean of 1.08 (8%) compared with the 15% found in previous measurements. Estimated unpolarized signatures from vertical and horizontal components agreed with unpolarized measurements with a slope coefficient of .85 to .99. Target signature for major ship facets and for total ship showed no discernable degree of polarization. A total of 37 IDL programs developed for this analysis can be assembled as a package for future data processing"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/polarizationeffe109458828"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["189 p."]},{"key":"dc:title","label":"Title","values":["Polarization effects on infrared target contrast"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, Brazil Air Force"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cleary, David D.","Cooper, Alfred W."],"dc:contributor.other":["Information Warfare Academic Group"],"dc:creator":["Pontes, Marcos Cesar"],"dc:date.accessioned":["2012-08-09T19:22:59Z"],"dc:date.available":["2012-08-09T19:22:59Z"],"dc:date.issued":["1998-09"],"dc:description.abstract":["An analysis has been carried out of a data base of polarized long wave infrared images of the instrumented Research Vessel POINT SUR recorded over a period of two days during the EOPACE measurements series in San Diego Bay in 1996. The measurements were made from a land site on Point Loma with an AGA780 sensor with internally mounted polarization filters. The objectives of the analysis were to determine a possible influence of target aspect angle on the polarization signature, to compare polarization contrast improvement in San Diego Bay with previous measurements in the North Atlantic, and to validate by measurement the estimation of unpolarized signature from vertical and horizontal components. 5508 images representing 70 cases with vertical, horizontal and unpolarized sequences were analyzed. Using a horizontal polarizer, target to background contrast improvement was found with a mean of 1.08 (8%) compared with the 15% found in previous measurements. Estimated unpolarized signatures from vertical and horizontal components agreed with unpolarized measurements with a slope coefficient of .85 to .99. Target signature for major ship facets and for total ship showed no discernable degree of polarization. A total of 37 IDL programs developed for this analysis can be assembled as a package for future data processing"],"dc:description.uri":["http://archive.org/details/polarizationeffe109458828"],"dc:format.extent":["189 p."],"dc:identifier.programcode":["596 (Electronic Warfare Systems (International)"],"dc:identifier.uri":["https://hdl.handle.net/10945/8828"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["3ca085ea-3ce5-45da-9273-fe2cbe728c6d"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Thermal Imaging","Polarization","Target Contrast","Infrared Radiation"],"dc:title":["Polarization effects on infrared target contrast"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, Brazil Air Force"],"thesis:degree_discipline":["Systems Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Systems Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:44:33Z"}