{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/9140"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/9140","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Vibration measurements on the Phalanx electro-optical stabilization system","abstract":"The installation of the new PHALANX Surface Mode (PSUM) upgrade will enable the PHALANX to handle a wider range of threats, such as a small boat approaching the ship. The objective of the research described in this thesis was to measure the vibration of a prototype forward looking infrared (FLIR) camera stabilizer system during live-fire tests to evaluate its performance. Uniaxial, triaxial, and angular accelerometers were mounted at 19 different locations on the stabilizer and on the camera. Acceleration data were collected during eight live fire tests conducted at a Navy range, and the results analyzed. The power spectral densities (PSD) of the input linear accelerations at the stabilizer mounting points and the resulting linear accelerations at key locations on the stabilizer were calculated. The azimuth and elevation angular displacements of the FLIR camera mount were also calculated. The azimuth and elevation angular displacement of the plane of the stabilizer pedestal mounting points were also calculated. Recommendations are made for follow-on studies.","abstract_html":"The installation of the new PHALANX Surface Mode (PSUM) upgrade will enable the PHALANX to handle a wider range of threats, such as a small boat approaching the ship. The objective of the research described in this thesis was to measure the vibration of a prototype forward looking infrared (FLIR) camera stabilizer system during live-fire tests to evaluate its performance. Uniaxial, triaxial, and angular accelerometers were mounted at 19 different locations on the stabilizer and on the camera. Acceleration data were collected during eight live fire tests conducted at a Navy range, and the results analyzed. The power spectral densities (PSD) of the input linear accelerations at the stabilizer mounting points and the resulting linear accelerations at key locations on the stabilizer were calculated. The azimuth and elevation angular displacements of the FLIR camera mount were also calculated. The azimuth and elevation angular displacement of the plane of the stabilizer pedestal mounting points were also calculated. Recommendations are made for follow-on studies.","abstract_has_math":false,"creators":["Schmidt, James E."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Engineering Acoustics","degree_level":"Masters","degree_discipline":"Engineering Acoustics","degree_department":"Engineering Acoustics Academic Committee","school":null,"contributors":[],"advisors":["Baker, Steven R."],"committee_chairs":[],"committee_members":["Keolian, Robert M."],"year":1996,"date_issued":"1996-09","date_published":"1996-09","updated_at":"2026-11-26T00:20:39Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/9140","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/9140","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F9140","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F9140","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Baker, Steven R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Keolian, Robert M."]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Acoustics Academic Committee"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Schmidt, James E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["September 1996"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:24:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:24:37Z"]},{"key":"dc:date.issued","label":"Date","values":["1996-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Acoustics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Engineering Acoustics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["PHALANX","M61A1","Gatling gun","PHALANX surface mode upgrade"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/9140"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The installation of the new PHALANX Surface Mode (PSUM) upgrade will enable the PHALANX to handle a wider range of threats, such as a small boat approaching the ship. The objective of the research described in this thesis was to measure the vibration of a prototype forward looking infrared (FLIR) camera stabilizer system during live-fire tests to evaluate its performance. Uniaxial, triaxial, and angular accelerometers were mounted at 19 different locations on the stabilizer and on the camera. Acceleration data were collected during eight live fire tests conducted at a Navy range, and the results analyzed. The power spectral densities (PSD) of the input linear accelerations at the stabilizer mounting points and the resulting linear accelerations at key locations on the stabilizer were calculated. The azimuth and elevation angular displacements of the FLIR camera mount were also calculated. The azimuth and elevation angular displacement of the plane of the stabilizer pedestal mounting points were also calculated. Recommendations are made for follow-on studies."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/vibrationmeasure109459140"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["x, 144 p."]},{"key":"dc:title","label":"Title","values":["Vibration measurements on the Phalanx electro-optical stabilization system"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Baker, Steven R."],"dc:contributor.committeemember":["Keolian, Robert M."],"dc:contributor.department":["Engineering Acoustics Academic Committee"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Schmidt, James E."],"dc:date":["September 1996"],"dc:date.accessioned":["2012-08-09T19:24:37Z"],"dc:date.available":["2012-08-09T19:24:37Z"],"dc:date.issued":["1996-09"],"dc:description.abstract":["The installation of the new PHALANX Surface Mode (PSUM) upgrade will enable the PHALANX to handle a wider range of threats, such as a small boat approaching the ship. The objective of the research described in this thesis was to measure the vibration of a prototype forward looking infrared (FLIR) camera stabilizer system during live-fire tests to evaluate its performance. Uniaxial, triaxial, and angular accelerometers were mounted at 19 different locations on the stabilizer and on the camera. Acceleration data were collected during eight live fire tests conducted at a Navy range, and the results analyzed. The power spectral densities (PSD) of the input linear accelerations at the stabilizer mounting points and the resulting linear accelerations at key locations on the stabilizer were calculated. The azimuth and elevation angular displacements of the FLIR camera mount were also calculated. The azimuth and elevation angular displacement of the plane of the stabilizer pedestal mounting points were also calculated. Recommendations are made for follow-on studies."],"dc:description.uri":["http://archive.org/details/vibrationmeasure109459140"],"dc:format.extent":["x, 144 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/9140"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["PHALANX","M61A1","Gatling gun","PHALANX surface mode upgrade"],"dc:title":["Vibration measurements on the Phalanx electro-optical stabilization system"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Engineering Acoustics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Engineering Acoustics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:20:39Z"}