{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/949"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/949","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Barrel wear reduction in rail guns: the effects of known and controlled rail spacing on low voltage electrical contact and the hard chrome plating of copper-tungsten rail and pure copper rails","abstract":"100 m/s). Low voltage electrical contact was not maintained for some experimental shots and non-parallel rails were the suspected cause. In this thesis, we used a non-contact capacitive sensor to determine rail spacing to within 2/kAcm10mael, so that the rails will be parallel within small tolerances. Several rails were used in these experiments: 75-25 copper-tungsten, chromium-plated 75-25 Cu-W, and chromium-plated pure copper rails. Improving the control of rail spacing and parallelity did not ensure low-voltage electrical contact for our configurations. The largest damage was observed for chromium-plated copper rails and the least damage occurred for chromium-plated 75-25 Cu-W rails.","abstract_html":"100 m/s). Low voltage electrical contact was not maintained for some experimental shots and non-parallel rails were the suspected cause. In this thesis, we used a non-contact capacitive sensor to determine rail spacing to within 2/kAcm10mael, so that the rails will be parallel within small tolerances. Several rails were used in these experiments: 75-25 copper-tungsten, chromium-plated 75-25 Cu-W, and chromium-plated pure copper rails. Improving the control of rail spacing and parallelity did not ensure low-voltage electrical contact for our configurations. The largest damage was observed for chromium-plated copper rails and the least damage occurred for chromium-plated 75-25 Cu-W rails.","abstract_has_math":false,"creators":["McNeal, Cedric J."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Maier, William B., II","Harkins, Richard"],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-06","date_published":"2003-06","updated_at":"2026-11-19T06:45:16Z","subjects":["Electric contacts"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/949","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/949","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F949","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Maier, William B., II","Harkins, Richard"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["McNeal, Cedric J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 2003"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:30:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:30:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2003-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Rail gun","Low voltage electrical contact","Non-contact capacitive sensor","Hard chrome plating"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electric contacts"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/949"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["100 m/s). Low voltage electrical contact was not maintained for some experimental shots and non-parallel rails were the suspected cause. In this thesis, we used a non-contact capacitive sensor to determine rail spacing to within 2/kAcm10mael, so that the rails will be parallel within small tolerances. Several rails were used in these experiments: 75-25 copper-tungsten, chromium-plated 75-25 Cu-W, and chromium-plated pure copper rails. Improving the control of rail spacing and parallelity did not ensure low-voltage electrical contact for our configurations. The largest damage was observed for chromium-plated copper rails and the least damage occurred for chromium-plated 75-25 Cu-W rails."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/barrelwearreduct10945949"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 49 p. : ill. (chiefly col.)"]},{"key":"dc:title","label":"Title","values":["Barrel wear reduction in rail guns: the effects of known and controlled rail spacing on low voltage electrical contact and the hard chrome plating of copper-tungsten rail and pure copper rails"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Maier, William B., II","Harkins, Richard"],"dc:contributor.department":["Physics"],"dc:creator":["McNeal, Cedric J."],"dc:date":["June 2003"],"dc:date.accessioned":["2012-03-14T17:30:03Z"],"dc:date.available":["2012-03-14T17:30:03Z"],"dc:date.issued":["2003-06"],"dc:description.abstract":["100 m/s). Low voltage electrical contact was not maintained for some experimental shots and non-parallel rails were the suspected cause. In this thesis, we used a non-contact capacitive sensor to determine rail spacing to within 2/kAcm10mael, so that the rails will be parallel within small tolerances. Several rails were used in these experiments: 75-25 copper-tungsten, chromium-plated 75-25 Cu-W, and chromium-plated pure copper rails. Improving the control of rail spacing and parallelity did not ensure low-voltage electrical contact for our configurations. The largest damage was observed for chromium-plated copper rails and the least damage occurred for chromium-plated 75-25 Cu-W rails."],"dc:description.uri":["http://archive.org/details/barrelwearreduct10945949"],"dc:format.extent":["xiv, 49 p. : ill. (chiefly col.)"],"dc:identifier.uri":["https://hdl.handle.net/10945/949"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Rail gun","Low voltage electrical contact","Non-contact capacitive sensor","Hard chrome plating"],"dc:subject.lcsh":["Electric contacts"],"dc:title":["Barrel wear reduction in rail guns: the effects of known and controlled rail spacing on low voltage electrical contact and the hard chrome plating of copper-tungsten rail and pure copper rails"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"local:etd.verified":["no"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:45:16Z"}