{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/9512"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/9512","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An experimental study of Tonks-Dattner resonances in rare gas plasmas.","abstract":"A quantitative experimental study of the dipole Tonks-Dattner resonance oscillations of a cylindrical plasma column has been made for neon, argon and xenon plasma columns. Discharges were operated in the range of a few mTorr and resonances have been observed in the UHF and microwave frequency range. The resonances have been studied using strip-line and waveguide techniques and diagnostic studies have been made employing Langmuir probes and microwave cavity methods. For xenon, good agreement has been found with the theory of Parker, Nickel and Gould but for neon and argon definite discrepancies exist. This departure has been attributed to ion mean free paths which are not long compared to the tube radius. The effect of ion collisions seems to be to raise the electron density near the wall of the tube causing the resonances to occur at higher frequencies than are predicted by theory for the case of long ion mean free paths. The appearance of fewer and broader resonances than are observed in mercury columns is attributed primarily to the occurrence of moving striations which produce variations of electron density of about t 50% of the average.","abstract_html":"A quantitative experimental study of the dipole Tonks-Dattner resonance oscillations of a cylindrical plasma column has been made for neon, argon and xenon plasma columns. Discharges were operated in the range of a few mTorr and resonances have been observed in the UHF and microwave frequency range. The resonances have been studied using strip-line and waveguide techniques and diagnostic studies have been made employing Langmuir probes and microwave cavity methods. For xenon, good agreement has been found with the theory of Parker, Nickel and Gould but for neon and argon definite discrepancies exist. This departure has been attributed to ion mean free paths which are not long compared to the tube radius. The effect of ion collisions seems to be to raise the electron density near the wall of the tube causing the resonances to occur at higher frequencies than are predicted by theory for the case of long ion mean free paths. The appearance of fewer and broader resonances than are observed in mercury columns is attributed primarily to the occurrence of moving striations which produce variations of electron density of about t 50% of the average.","abstract_has_math":false,"creators":["Hart, David Austin"],"institution":"Naval Postgraduate School","degree_name":"Ph.D.","degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Oleson, Norman L."],"committee_chairs":[],"committee_members":[],"year":1966,"date_issued":"1966-12","date_published":"1966-12","updated_at":"2026-11-21T22:40:21Z","subjects":["Physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/9512","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/9512","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F9512","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oleson, Norman L."]},{"key":"dc:creator","label":"Author","values":["Hart, David Austin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-09T19:32:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-09T19:32:02Z"]},{"key":"dc:date.issued","label":"Date","values":["1966-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/9512"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A quantitative experimental study of the dipole Tonks-Dattner resonance oscillations of a cylindrical plasma column has been made for neon, argon and xenon plasma columns. Discharges were operated in the range of a few mTorr and resonances have been observed in the UHF and microwave frequency range. The resonances have been studied using strip-line and waveguide techniques and diagnostic studies have been made employing Langmuir probes and microwave cavity methods. For xenon, good agreement has been found with the theory of Parker, Nickel and Gould but for neon and argon definite discrepancies exist. This departure has been attributed to ion mean free paths which are not long compared to the tube radius. The effect of ion collisions seems to be to raise the electron density near the wall of the tube causing the resonances to occur at higher frequencies than are predicted by theory for the case of long ion mean free paths. The appearance of fewer and broader resonances than are observed in mercury columns is attributed primarily to the occurrence of moving striations which produce variations of electron density of about t 50% of the average."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/anexperimentalst109459512"]},{"key":"dc:title","label":"Title","values":["An experimental study of Tonks-Dattner resonances in rare gas plasmas."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oleson, Norman L."],"dc:creator":["Hart, David Austin"],"dc:date.accessioned":["2012-08-09T19:32:02Z"],"dc:date.available":["2012-08-09T19:32:02Z"],"dc:date.issued":["1966-12"],"dc:description.abstract":["A quantitative experimental study of the dipole Tonks-Dattner resonance oscillations of a cylindrical plasma column has been made for neon, argon and xenon plasma columns. Discharges were operated in the range of a few mTorr and resonances have been observed in the UHF and microwave frequency range. The resonances have been studied using strip-line and waveguide techniques and diagnostic studies have been made employing Langmuir probes and microwave cavity methods. For xenon, good agreement has been found with the theory of Parker, Nickel and Gould but for neon and argon definite discrepancies exist. This departure has been attributed to ion mean free paths which are not long compared to the tube radius. The effect of ion collisions seems to be to raise the electron density near the wall of the tube causing the resonances to occur at higher frequencies than are predicted by theory for the case of long ion mean free paths. The appearance of fewer and broader resonances than are observed in mercury columns is attributed primarily to the occurrence of moving striations which produce variations of electron density of about t 50% of the average."],"dc:description.uri":["http://archive.org/details/anexperimentalst109459512"],"dc:identifier.uri":["https://hdl.handle.net/10945/9512"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Physics"],"dc:title":["An experimental study of Tonks-Dattner resonances in rare gas plasmas."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:40:21Z"}