{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:cee_etds-1127"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:cee_etds-1127","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Comparison of Steady-State Pipe Network Computer Programs","abstract":"Four widely used computer programs for the analysis of steady state flows in pipe networks are compared. These programs are NEWTH, written by Jeppson; KENTUCKY, written by Wood; FLOW, written by Epp and Fowler; and LIQSS, written by Stoner. Differences, similarities, advantages and disadvantages of these programs, and various options available are discussed for the benefit of possible future users. In addition, the efficiency of NEWTH, KENTUCKY, and FLOW was tested by simulating a typical network by each program. The listing of LIQSS was not available, and thus was not included in this comparison. In simulation, KENTUCKY used over twice the amount of CPU time as FLOW while NEWJTH used 26 percent more CPU time than did FLOW. Considering the efficiency comparison (including memory anti storage requirements, as well as CPU time) with the ease of preparing the input data, clarity of documentation, available options, and ease of adaption to computer systems did not leave any clear winner. Each program has its merits and may be best suited for a user in a particular situation.","abstract_html":"Four widely used computer programs for the analysis of steady state flows in pipe networks are compared. These programs are NEWTH, written by Jeppson; KENTUCKY, written by Wood; FLOW, written by Epp and Fowler; and LIQSS, written by Stoner. Differences, similarities, advantages and disadvantages of these programs, and various options available are discussed for the benefit of possible future users. In addition, the efficiency of NEWTH, KENTUCKY, and FLOW was tested by simulating a typical network by each program. The listing of LIQSS was not available, and thus was not included in this comparison. In simulation, KENTUCKY used over twice the amount of CPU time as FLOW while NEWJTH used 26 percent more CPU time than did FLOW. Considering the efficiency comparison (including memory anti storage requirements, as well as CPU time) with the ease of preparing the input data, clarity of documentation, available options, and ease of adaption to computer systems did not leave any clear winner. Each program has its merits and may be best suited for a user in a particular situation.","abstract_has_math":false,"creators":["Holloway, Michael Bernice"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil & Environmental Engineering","degree_department":null,"school":null,"contributors":["Hanif Chaudhry","William A. Drewry","Dennis J. Fallon","A. Osman Akan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:33:35Z","subjects":["Electronic data processing","Pipe networks","Computer programs","Civil Engineering","Computational Engineering","Computer Sciences"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/cee_etds/127","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/cee_etds/127","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Acee_etds-1127","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hanif Chaudhry","William A. Drewry","Dennis J. Fallon","A. Osman Akan"]},{"key":"dc:creator","label":"Author","values":["Holloway, Michael Bernice"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-10-27T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1982-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil & Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electronic data processing","Pipe networks","Computer programs","Civil Engineering","Computational Engineering","Computer Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/cee_etds/127"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Four widely used computer programs for the analysis of steady state flows in pipe networks are compared. These programs are NEWTH, written by Jeppson; KENTUCKY, written by Wood; FLOW, written by Epp and Fowler; and LIQSS, written by Stoner. Differences, similarities, advantages and disadvantages of these programs, and various options available are discussed for the benefit of possible future users. In addition, the efficiency of NEWTH, KENTUCKY, and FLOW was tested by simulating a typical network by each program. The listing of LIQSS was not available, and thus was not included in this comparison. In simulation, KENTUCKY used over twice the amount of CPU time as FLOW while NEWJTH used 26 percent more CPU time than did FLOW. Considering the efficiency comparison (including memory anti storage requirements, as well as CPU time) with the ease of preparing the input data, clarity of documentation, available options, and ease of adaption to computer systems did not leave any clear winner. Each program has its merits and may be best suited for a user in a particular situation."]},{"key":"dc:title","label":"Title","values":["Comparison of Steady-State Pipe Network Computer Programs"]}]}],"canonical_facts":{"dc:contributor":["Hanif Chaudhry","William A. Drewry","Dennis J. Fallon","A. Osman Akan"],"dc:creator":["Holloway, Michael Bernice"],"dc:date.available":["2023-10-27T07:00:00Z"],"dc:date.created":["1982-08-01T07:00:00Z"],"dc:description.abstract":["Four widely used computer programs for the analysis of steady state flows in pipe networks are compared. These programs are NEWTH, written by Jeppson; KENTUCKY, written by Wood; FLOW, written by Epp and Fowler; and LIQSS, written by Stoner. Differences, similarities, advantages and disadvantages of these programs, and various options available are discussed for the benefit of possible future users. In addition, the efficiency of NEWTH, KENTUCKY, and FLOW was tested by simulating a typical network by each program. The listing of LIQSS was not available, and thus was not included in this comparison. In simulation, KENTUCKY used over twice the amount of CPU time as FLOW while NEWJTH used 26 percent more CPU time than did FLOW. Considering the efficiency comparison (including memory anti storage requirements, as well as CPU time) with the ease of preparing the input data, clarity of documentation, available options, and ease of adaption to computer systems did not leave any clear winner. Each program has its merits and may be best suited for a user in a particular situation."],"dc:identifier":["https://digitalcommons.odu.edu/cee_etds/127"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Electronic data processing","Pipe networks","Computer programs","Civil Engineering","Computational Engineering","Computer Sciences"],"dc:title":["Comparison of Steady-State Pipe Network Computer Programs"],"thesis:degree_discipline":["Civil & Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:33:35Z"}