{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:cee_etds-1164"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:cee_etds-1164","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Computer-Aided Analysis and Design of Rectangular Buried Tank Walls and Its Safety Factor Evaluation Based on Yield Line Analysis","abstract":"This thesis presents the results of a study that determines the true safety factor of underground square reinforced concrete tank walls. The walls are analyzed and designed by elastic method. The amount and distribution of the reinforcement was determined by use of the alternate design method (working stress) in compliance with all ACI code requirements. The wall's ultimate moment was computed by use of yield line theory assuming non-isotropic reinforcement. The ultimate value of the earth pressure was computed and compared with the elastic analysis and design values to give the true safety factor. The results of this study indicate that the safety factor is a function of a number of parameters. Specifically for a square wall the safety factor increases with an increase in the size of the wall. However, the safety factor decreases with an increase in the width of the wall for a given height. For a given width, the safety factor increases with the increase in the height. The rate of change is not in direct proportion to the rate of the change in the size.","abstract_html":"This thesis presents the results of a study that determines the true safety factor of underground square reinforced concrete tank walls. The walls are analyzed and designed by elastic method. The amount and distribution of the reinforcement was determined by use of the alternate design method (working stress) in compliance with all ACI code requirements. The wall&#x27;s ultimate moment was computed by use of yield line theory assuming non-isotropic reinforcement. The ultimate value of the earth pressure was computed and compared with the elastic analysis and design values to give the true safety factor. The results of this study indicate that the safety factor is a function of a number of parameters. Specifically for a square wall the safety factor increases with an increase in the size of the wall. However, the safety factor decreases with an increase in the width of the wall for a given height. For a given width, the safety factor increases with the increase in the height. The rate of change is not in direct proportion to the rate of the change in the size.","abstract_has_math":false,"creators":["Fatoohi, Rakiya J."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil & Environmental Engineering","degree_department":null,"school":null,"contributors":["Leon R. L. Wang","Duc T. Nguyen","J. Mark Dorrepaal"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:43Z","subjects":["Concrete walls","Elastic analysis","Civil Engineering","Computer-Aided Engineering and Design","Structural Engineering"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/cee_etds/169","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/cee_etds/169","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Acee_etds-1164","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Acee_etds-1164","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Leon R. L. Wang","Duc T. Nguyen","J. Mark Dorrepaal"]},{"key":"dc:creator","label":"Author","values":["Fatoohi, Rakiya J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-11-06T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1987-10-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil & Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Concrete walls","Elastic analysis","Civil Engineering","Computer-Aided Engineering and Design","Structural Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/cee_etds/169"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the results of a study that determines the true safety factor of underground square reinforced concrete tank walls. The walls are analyzed and designed by elastic method. The amount and distribution of the reinforcement was determined by use of the alternate design method (working stress) in compliance with all ACI code requirements. The wall's ultimate moment was computed by use of yield line theory assuming non-isotropic reinforcement. The ultimate value of the earth pressure was computed and compared with the elastic analysis and design values to give the true safety factor. The results of this study indicate that the safety factor is a function of a number of parameters. Specifically for a square wall the safety factor increases with an increase in the size of the wall. However, the safety factor decreases with an increase in the width of the wall for a given height. For a given width, the safety factor increases with the increase in the height. The rate of change is not in direct proportion to the rate of the change in the size."]},{"key":"dc:title","label":"Title","values":["Computer-Aided Analysis and Design of Rectangular Buried Tank Walls and Its Safety Factor Evaluation Based on Yield Line Analysis"]}]}],"canonical_facts":{"dc:contributor":["Leon R. L. Wang","Duc T. Nguyen","J. Mark Dorrepaal"],"dc:creator":["Fatoohi, Rakiya J."],"dc:date.available":["2023-11-06T08:00:00Z"],"dc:date.created":["1987-10-01T07:00:00Z"],"dc:description.abstract":["This thesis presents the results of a study that determines the true safety factor of underground square reinforced concrete tank walls. The walls are analyzed and designed by elastic method. The amount and distribution of the reinforcement was determined by use of the alternate design method (working stress) in compliance with all ACI code requirements. The wall's ultimate moment was computed by use of yield line theory assuming non-isotropic reinforcement. The ultimate value of the earth pressure was computed and compared with the elastic analysis and design values to give the true safety factor. The results of this study indicate that the safety factor is a function of a number of parameters. Specifically for a square wall the safety factor increases with an increase in the size of the wall. However, the safety factor decreases with an increase in the width of the wall for a given height. For a given width, the safety factor increases with the increase in the height. The rate of change is not in direct proportion to the rate of the change in the size."],"dc:identifier":["https://digitalcommons.odu.edu/cee_etds/169"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Concrete walls","Elastic analysis","Civil Engineering","Computer-Aided Engineering and Design","Structural Engineering"],"dc:title":["Computer-Aided Analysis and Design of Rectangular Buried Tank Walls and Its Safety Factor Evaluation Based on Yield Line Analysis"],"thesis:degree_discipline":["Civil & Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:43Z"}