{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:cee_etds-1198"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:cee_etds-1198","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Accuracy Comparison of Numerical Integration Algorithms for Real-Time Hybrid Simulations","abstract":"The use of accurate numerical integration algorithms is one of the key factors for a successful real-time hybrid simulation (RTHS). In RTHSs, explicit integration algorithms are preferred more than implicit methods since all calculations need to be completed within a given time step during simulation. Explicit methods require the use of effective stiffness and damping for experimental substructures, which are incorporated into the calculation of the integration parameters. In general, those values that are greater than the expected stiffness and damping of the experimental substructure are used to ensure the stability of simulation. If a rate-dependent and nonlinear experimental substructure is used, the use of excessively large values in the equivalent stiffness or damping may be required to ensure the stability of simulation over a wide range of frequency responses of the experimental substructure. However, the large values of the equivalent stiffness or damping can cause an error in the response update of the structural system, resulting in inaccurate simulation results. In this presentation, the effect of the use of large values in the equivalent stiffness or damping on the accuracy of numerical integration methods is investigated for a single-story building with a nonlinear viscous damper mounted on a diagonal bracing. In this case, the simulation results can be sensitive to the selection of equivalent stiffness and damping of the nonlinear viscous damper due to large axial stiffness of the diagonal bracing. The accuracy and stability of three different integration methods are investigated with different values of time delay, equivalent stiffness and the damping coefficientsof the nonlinear viscous damper, along with the variation of the stiffness of the diagonal bracing. It is expected that the results of this study can provide guidance for the proper selection of integration algorithms to increase the accuracy of RTHS.","abstract_html":"The use of accurate numerical integration algorithms is one of the key factors for a successful real-time hybrid simulation (RTHS). In RTHSs, explicit integration algorithms are preferred more than implicit methods since all calculations need to be completed within a given time step during simulation. Explicit methods require the use of effective stiffness and damping for experimental substructures, which are incorporated into the calculation of the integration parameters. In general, those values that are greater than the expected stiffness and damping of the experimental substructure are used to ensure the stability of simulation. If a rate-dependent and nonlinear experimental substructure is used, the use of excessively large values in the equivalent stiffness or damping may be required to ensure the stability of simulation over a wide range of frequency responses of the experimental substructure. However, the large values of the equivalent stiffness or damping can cause an error in the response update of the structural system, resulting in inaccurate simulation results. In this presentation, the effect of the use of large values in the equivalent stiffness or damping on the accuracy of numerical integration methods is investigated for a single-story building with a nonlinear viscous damper mounted on a diagonal bracing. In this case, the simulation results can be sensitive to the selection of equivalent stiffness and damping of the nonlinear viscous damper due to large axial stiffness of the diagonal bracing. The accuracy and stability of three different integration methods are investigated with different values of time delay, equivalent stiffness and the damping coefficientsof the nonlinear viscous damper, along with the variation of the stiffness of the diagonal bracing. It is expected that the results of this study can provide guidance for the proper selection of integration algorithms to increase the accuracy of RTHS.","abstract_has_math":false,"creators":["Reddy, Ganesh Anant"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil & Environmental Engineering","degree_department":null,"school":null,"contributors":["Yunbyeong Chae","Zia Razzaq","Reza Moradi"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:33:46Z","subjects":["Hybrid computer simulation","Integration methods","Applied Mathematics","Civil Engineering","Computational Engineering","Theory and Algorithms"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/cee_etds/198","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/cee_etds/198","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Acee_etds-1198","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yunbyeong Chae","Zia Razzaq","Reza Moradi"]},{"key":"dc:creator","label":"Author","values":["Reddy, Ganesh Anant"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-11-09T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-07-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil & Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hybrid computer simulation","Integration methods","Applied Mathematics","Civil Engineering","Computational Engineering","Theory and Algorithms"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/cee_etds/198"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of accurate numerical integration algorithms is one of the key factors for a successful real-time hybrid simulation (RTHS). In RTHSs, explicit integration algorithms are preferred more than implicit methods since all calculations need to be completed within a given time step during simulation. Explicit methods require the use of effective stiffness and damping for experimental substructures, which are incorporated into the calculation of the integration parameters. In general, those values that are greater than the expected stiffness and damping of the experimental substructure are used to ensure the stability of simulation. If a rate-dependent and nonlinear experimental substructure is used, the use of excessively large values in the equivalent stiffness or damping may be required to ensure the stability of simulation over a wide range of frequency responses of the experimental substructure. However, the large values of the equivalent stiffness or damping can cause an error in the response update of the structural system, resulting in inaccurate simulation results. In this presentation, the effect of the use of large values in the equivalent stiffness or damping on the accuracy of numerical integration methods is investigated for a single-story building with a nonlinear viscous damper mounted on a diagonal bracing. In this case, the simulation results can be sensitive to the selection of equivalent stiffness and damping of the nonlinear viscous damper due to large axial stiffness of the diagonal bracing. The accuracy and stability of three different integration methods are investigated with different values of time delay, equivalent stiffness and the damping coefficientsof the nonlinear viscous damper, along with the variation of the stiffness of the diagonal bracing. It is expected that the results of this study can provide guidance for the proper selection of integration algorithms to increase the accuracy of RTHS."]},{"key":"dc:title","label":"Title","values":["Accuracy Comparison of Numerical Integration Algorithms for Real-Time Hybrid Simulations"]}]}],"canonical_facts":{"dc:contributor":["Yunbyeong Chae","Zia Razzaq","Reza Moradi"],"dc:creator":["Reddy, Ganesh Anant"],"dc:date.available":["2023-11-09T08:00:00Z"],"dc:date.created":["2015-07-01T07:00:00Z"],"dc:description.abstract":["The use of accurate numerical integration algorithms is one of the key factors for a successful real-time hybrid simulation (RTHS). In RTHSs, explicit integration algorithms are preferred more than implicit methods since all calculations need to be completed within a given time step during simulation. Explicit methods require the use of effective stiffness and damping for experimental substructures, which are incorporated into the calculation of the integration parameters. In general, those values that are greater than the expected stiffness and damping of the experimental substructure are used to ensure the stability of simulation. If a rate-dependent and nonlinear experimental substructure is used, the use of excessively large values in the equivalent stiffness or damping may be required to ensure the stability of simulation over a wide range of frequency responses of the experimental substructure. However, the large values of the equivalent stiffness or damping can cause an error in the response update of the structural system, resulting in inaccurate simulation results. In this presentation, the effect of the use of large values in the equivalent stiffness or damping on the accuracy of numerical integration methods is investigated for a single-story building with a nonlinear viscous damper mounted on a diagonal bracing. In this case, the simulation results can be sensitive to the selection of equivalent stiffness and damping of the nonlinear viscous damper due to large axial stiffness of the diagonal bracing. The accuracy and stability of three different integration methods are investigated with different values of time delay, equivalent stiffness and the damping coefficientsof the nonlinear viscous damper, along with the variation of the stiffness of the diagonal bracing. It is expected that the results of this study can provide guidance for the proper selection of integration algorithms to increase the accuracy of RTHS."],"dc:identifier":["https://digitalcommons.odu.edu/cee_etds/198"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Hybrid computer simulation","Integration methods","Applied Mathematics","Civil Engineering","Computational Engineering","Theory and Algorithms"],"dc:title":["Accuracy Comparison of Numerical Integration Algorithms for Real-Time Hybrid Simulations"],"thesis:degree_discipline":["Civil & Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:33:46Z"}