{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:cee_etds-1225"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:cee_etds-1225","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Downstream Effects of Post Aerobic Digestion and Divalent Cation Treatment: Dewaterability, Phosphorus Mitigation, and Process Odors","abstract":"This study evaluated post-aerobic digestion (PAD) with aeration, mixing, and divalent cation addition to improve phosphorus capture, dewaterability, and odor control in thermal hydrolysis process (THP)–treated anaerobic digestate at the Hampton Roads Sanitation District’s Atlantic Treatment Plant. A three-day PAD process was operated under constant air flow (5 LPM) and dissolved oxygen (DO)-setpoint (0.2 mg/L) aeration conditions with Ca(OH)₂ or Mg(OH)₂ dosing. Aeration and mixing alone increased polymer demand by 14–46 % relative to untreated influent, indicating enhanced extracellular polymeric substance release. Chemical conditioning partially mitigated this increase but did not restore polymer demand to baseline levels. Dewatered cake total solids remained near the influent average (29–30%), with minor improvements of up to 2.7 percentage points observed under certain calcium treatments. Overdosing magnesium beyond a 1:1 Mg:P molar ratio provided no additional benefit. Phosphorus removal was greatest under Mg(OH)₂ dosing under 0.2 mg/L DO-setpoint aeration, which reduced orthophosphate and total phosphorus in the filtrate by up to 88% and 86%, respectively. Ca(OH)₂ performed better under constant air flow compared to the 0.2 mg/L DO setpoint aeration setting, increasing total solids by 2% and retaining up to 92% of total phosphorus in the dewatered cake. Phosphorus capture was maximized near pH 8.5; lower and higher pH values reduced retention. Odor analysis showed that ammonia was the most abundant compound by concentration across all treatments, while methyl mercaptan exhibited the highest odor activity values and was the dominant contributor to overall odor perception. Aeration alone reduced total volatile sulfur compound (TVOSC) emissions, whereas the combination of aeration, mixing, and chemical addition increased them. These findings demonstrate that optimizing nutrient recovery, polymer consumption, and odor control in THP-treated biosolids requires balancing aeration intensity, mixing, and divalent-cation dose.","abstract_html":"This study evaluated post-aerobic digestion (PAD) with aeration, mixing, and divalent cation addition to improve phosphorus capture, dewaterability, and odor control in thermal hydrolysis process (THP)–treated anaerobic digestate at the Hampton Roads Sanitation District’s Atlantic Treatment Plant. A three-day PAD process was operated under constant air flow (5 LPM) and dissolved oxygen (DO)-setpoint (0.2 mg/L) aeration conditions with Ca(OH)₂ or Mg(OH)₂ dosing. Aeration and mixing alone increased polymer demand by 14–46 % relative to untreated influent, indicating enhanced extracellular polymeric substance release. Chemical conditioning partially mitigated this increase but did not restore polymer demand to baseline levels. Dewatered cake total solids remained near the influent average (29–30%), with minor improvements of up to 2.7 percentage points observed under certain calcium treatments. Overdosing magnesium beyond a 1:1 Mg:P molar ratio provided no additional benefit. Phosphorus removal was greatest under Mg(OH)₂ dosing under 0.2 mg/L DO-setpoint aeration, which reduced orthophosphate and total phosphorus in the filtrate by up to 88% and 86%, respectively. Ca(OH)₂ performed better under constant air flow compared to the 0.2 mg/L DO setpoint aeration setting, increasing total solids by 2% and retaining up to 92% of total phosphorus in the dewatered cake. Phosphorus capture was maximized near pH 8.5; lower and higher pH values reduced retention. Odor analysis showed that ammonia was the most abundant compound by concentration across all treatments, while methyl mercaptan exhibited the highest odor activity values and was the dominant contributor to overall odor perception. Aeration alone reduced total volatile sulfur compound (TVOSC) emissions, whereas the combination of aeration, mixing, and chemical addition increased them. These findings demonstrate that optimizing nutrient recovery, polymer consumption, and odor control in THP-treated biosolids requires balancing aeration intensity, mixing, and divalent-cation dose.","abstract_has_math":false,"creators":["Garcia, Maya Marisol Quijano"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil & Environmental Engineering","degree_department":null,"school":null,"contributors":["Gary Schafran","Mujde Erten-Unal","Christopher Wilson"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:43Z","subjects":["Post-aerobic digestion","Thermal hydrolysis process","Total volatile sulfur compound","Dissolved oxygen","Engineering","Environmental Sciences","Other Engineering","Water Resource Management"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\" target=\"_blank\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["9798197809209"],"render_values":[{"text":"9798197809209","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/cee_etds/225","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/cee_etds/225","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Acee_etds-1225","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Acee_etds-1225","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gary Schafran","Mujde Erten-Unal","Christopher Wilson"]},{"key":"dc:creator","label":"Author","values":["Garcia, Maya Marisol Quijano"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-15T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-04-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil & Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Post-aerobic digestion","Thermal hydrolysis process","Total volatile sulfur compound","Dissolved oxygen","Engineering","Environmental Sciences","Other Engineering","Water Resource Management"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\" target=\"_blank\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["9798197809209","https://digitalcommons.odu.edu/cee_etds/225"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study evaluated post-aerobic digestion (PAD) with aeration, mixing, and divalent cation addition to improve phosphorus capture, dewaterability, and odor control in thermal hydrolysis process (THP)–treated anaerobic digestate at the Hampton Roads Sanitation District’s Atlantic Treatment Plant. A three-day PAD process was operated under constant air flow (5 LPM) and dissolved oxygen (DO)-setpoint (0.2 mg/L) aeration conditions with Ca(OH)₂ or Mg(OH)₂ dosing. Aeration and mixing alone increased polymer demand by 14–46 % relative to untreated influent, indicating enhanced extracellular polymeric substance release. Chemical conditioning partially mitigated this increase but did not restore polymer demand to baseline levels. Dewatered cake total solids remained near the influent average (29–30%), with minor improvements of up to 2.7 percentage points observed under certain calcium treatments. Overdosing magnesium beyond a 1:1 Mg:P molar ratio provided no additional benefit. Phosphorus removal was greatest under Mg(OH)₂ dosing under 0.2 mg/L DO-setpoint aeration, which reduced orthophosphate and total phosphorus in the filtrate by up to 88% and 86%, respectively. Ca(OH)₂ performed better under constant air flow compared to the 0.2 mg/L DO setpoint aeration setting, increasing total solids by 2% and retaining up to 92% of total phosphorus in the dewatered cake. Phosphorus capture was maximized near pH 8.5; lower and higher pH values reduced retention. Odor analysis showed that ammonia was the most abundant compound by concentration across all treatments, while methyl mercaptan exhibited the highest odor activity values and was the dominant contributor to overall odor perception. Aeration alone reduced total volatile sulfur compound (TVOSC) emissions, whereas the combination of aeration, mixing, and chemical addition increased them. These findings demonstrate that optimizing nutrient recovery, polymer consumption, and odor control in THP-treated biosolids requires balancing aeration intensity, mixing, and divalent-cation dose."]},{"key":"dc:title","label":"Title","values":["Downstream Effects of Post Aerobic Digestion and Divalent Cation Treatment: Dewaterability, Phosphorus Mitigation, and Process Odors"]}]}],"canonical_facts":{"dc:contributor":["Gary Schafran","Mujde Erten-Unal","Christopher Wilson"],"dc:creator":["Garcia, Maya Marisol Quijano"],"dc:date.available":["2026-07-15T07:00:00Z"],"dc:date.created":["2026-04-01T07:00:00Z"],"dc:description.abstract":["This study evaluated post-aerobic digestion (PAD) with aeration, mixing, and divalent cation addition to improve phosphorus capture, dewaterability, and odor control in thermal hydrolysis process (THP)–treated anaerobic digestate at the Hampton Roads Sanitation District’s Atlantic Treatment Plant. A three-day PAD process was operated under constant air flow (5 LPM) and dissolved oxygen (DO)-setpoint (0.2 mg/L) aeration conditions with Ca(OH)₂ or Mg(OH)₂ dosing. Aeration and mixing alone increased polymer demand by 14–46 % relative to untreated influent, indicating enhanced extracellular polymeric substance release. Chemical conditioning partially mitigated this increase but did not restore polymer demand to baseline levels. Dewatered cake total solids remained near the influent average (29–30%), with minor improvements of up to 2.7 percentage points observed under certain calcium treatments. Overdosing magnesium beyond a 1:1 Mg:P molar ratio provided no additional benefit. Phosphorus removal was greatest under Mg(OH)₂ dosing under 0.2 mg/L DO-setpoint aeration, which reduced orthophosphate and total phosphorus in the filtrate by up to 88% and 86%, respectively. Ca(OH)₂ performed better under constant air flow compared to the 0.2 mg/L DO setpoint aeration setting, increasing total solids by 2% and retaining up to 92% of total phosphorus in the dewatered cake. Phosphorus capture was maximized near pH 8.5; lower and higher pH values reduced retention. Odor analysis showed that ammonia was the most abundant compound by concentration across all treatments, while methyl mercaptan exhibited the highest odor activity values and was the dominant contributor to overall odor perception. Aeration alone reduced total volatile sulfur compound (TVOSC) emissions, whereas the combination of aeration, mixing, and chemical addition increased them. These findings demonstrate that optimizing nutrient recovery, polymer consumption, and odor control in THP-treated biosolids requires balancing aeration intensity, mixing, and divalent-cation dose."],"dc:identifier":["9798197809209","https://digitalcommons.odu.edu/cee_etds/225"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\" target=\"_blank\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Post-aerobic digestion","Thermal hydrolysis process","Total volatile sulfur compound","Dissolved oxygen","Engineering","Environmental Sciences","Other Engineering","Water Resource Management"],"dc:title":["Downstream Effects of Post Aerobic Digestion and Divalent Cation Treatment: Dewaterability, Phosphorus Mitigation, and Process Odors"],"thesis:degree_discipline":["Civil & Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:43Z"}