{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:cee_etds-1228"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:cee_etds-1228","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Validating Low Dissolved Oxygen Measurements to Improve Process Performance and Control","abstract":"Conventional operation of wastewater treatment plants (WWTPs) is to maintain a dissolved oxygen (DO) concentration at or above 2.0 mg/L in the aeration process for biological nutrient removal (BNR). However, the adoption of operating at low DO in WWTP aeration systems has led to the improvement of process efficiency and reduced aeration energy requirements, making the transition to low DO favorable. Furthermore, as systems transition to oxygen-limiting conditions, the accuracy in DO measurements becomes increasingly important. Many plants use DO sensors to regularly control aeration processes, but their precision and accuracy at (ultra) low DO concentrations are less established. If a system lacks certainty in a DO measurement, both process optimization and BNR performance can become hindered. The research in this study evaluated various methods to validate low and ultra-low DO measurements for a BNR system. Pilot-scale and full-scale studies were conducted to assess phosphorus and nitrogen removal performance under these limiting DO conditions. Additionally, pilot-scale tests were conducted to evaluate DO sensor performance, compare sensor measurement methods, and determine practical approaches to verify DO concentrations under controlled conditions. Multiple methods were examined and applied over a range of operation conditions representative of wastewater treatment processes. The results from this work demonstrated that effective phosphorus removal can be achieved at DO concentrations significantly below conventional operating targets. PAO Ko values were observed at DO concentrations below 0.13 mg/L in batch tests. Additionally, significant differences in DO sensor performance were observed among measurement technologies, specifically within the ultra-low DO range (< 0.2 mg/L). Optical sensors generally displayed improved accuracy, precision, and stability compared to electrochemical sensors, with the PyroScience TROXROB10 optical sensor providing the most reliable measurements.","abstract_html":"Conventional operation of wastewater treatment plants (WWTPs) is to maintain a dissolved oxygen (DO) concentration at or above 2.0 mg/L in the aeration process for biological nutrient removal (BNR). However, the adoption of operating at low DO in WWTP aeration systems has led to the improvement of process efficiency and reduced aeration energy requirements, making the transition to low DO favorable. Furthermore, as systems transition to oxygen-limiting conditions, the accuracy in DO measurements becomes increasingly important. Many plants use DO sensors to regularly control aeration processes, but their precision and accuracy at (ultra) low DO concentrations are less established. If a system lacks certainty in a DO measurement, both process optimization and BNR performance can become hindered. The research in this study evaluated various methods to validate low and ultra-low DO measurements for a BNR system. Pilot-scale and full-scale studies were conducted to assess phosphorus and nitrogen removal performance under these limiting DO conditions. Additionally, pilot-scale tests were conducted to evaluate DO sensor performance, compare sensor measurement methods, and determine practical approaches to verify DO concentrations under controlled conditions. Multiple methods were examined and applied over a range of operation conditions representative of wastewater treatment processes. The results from this work demonstrated that effective phosphorus removal can be achieved at DO concentrations significantly below conventional operating targets. PAO Ko values were observed at DO concentrations below 0.13 mg/L in batch tests. Additionally, significant differences in DO sensor performance were observed among measurement technologies, specifically within the ultra-low DO range (&lt; 0.2 mg/L). Optical sensors generally displayed improved accuracy, precision, and stability compared to electrochemical sensors, with the PyroScience TROXROB10 optical sensor providing the most reliable measurements.","abstract_has_math":false,"creators":["Bradshaw, Hailey"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil & Environmental Engineering","degree_department":null,"school":null,"contributors":["Gary Scharfran","Charles Bott","Mujde Erten-Unal"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:34:25Z","subjects":["Biological Nutrient Removal","Dissolved Oxygen","Phosphorus","Environmental Engineering"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["9798193214670"],"render_values":[{"text":"9798193214670","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/cee_etds/228","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/cee_etds/228","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Acee_etds-1228","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gary Scharfran","Charles Bott","Mujde Erten-Unal"]},{"key":"dc:creator","label":"Author","values":["Bradshaw, Hailey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-10-02T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil & Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biological Nutrient Removal","Dissolved Oxygen","Phosphorus","Environmental Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["9798193214670","https://digitalcommons.odu.edu/cee_etds/228"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Conventional operation of wastewater treatment plants (WWTPs) is to maintain a dissolved oxygen (DO) concentration at or above 2.0 mg/L in the aeration process for biological nutrient removal (BNR). However, the adoption of operating at low DO in WWTP aeration systems has led to the improvement of process efficiency and reduced aeration energy requirements, making the transition to low DO favorable. Furthermore, as systems transition to oxygen-limiting conditions, the accuracy in DO measurements becomes increasingly important. Many plants use DO sensors to regularly control aeration processes, but their precision and accuracy at (ultra) low DO concentrations are less established. If a system lacks certainty in a DO measurement, both process optimization and BNR performance can become hindered. The research in this study evaluated various methods to validate low and ultra-low DO measurements for a BNR system. Pilot-scale and full-scale studies were conducted to assess phosphorus and nitrogen removal performance under these limiting DO conditions. Additionally, pilot-scale tests were conducted to evaluate DO sensor performance, compare sensor measurement methods, and determine practical approaches to verify DO concentrations under controlled conditions. Multiple methods were examined and applied over a range of operation conditions representative of wastewater treatment processes. The results from this work demonstrated that effective phosphorus removal can be achieved at DO concentrations significantly below conventional operating targets. PAO Ko values were observed at DO concentrations below 0.13 mg/L in batch tests. Additionally, significant differences in DO sensor performance were observed among measurement technologies, specifically within the ultra-low DO range (< 0.2 mg/L). Optical sensors generally displayed improved accuracy, precision, and stability compared to electrochemical sensors, with the PyroScience TROXROB10 optical sensor providing the most reliable measurements."]},{"key":"dc:title","label":"Title","values":["Validating Low Dissolved Oxygen Measurements to Improve Process Performance and Control"]}]}],"canonical_facts":{"dc:contributor":["Gary Scharfran","Charles Bott","Mujde Erten-Unal"],"dc:creator":["Bradshaw, Hailey"],"dc:date.available":["2026-10-02T07:00:00Z"],"dc:date.created":["2016-08-01T07:00:00Z"],"dc:description.abstract":["Conventional operation of wastewater treatment plants (WWTPs) is to maintain a dissolved oxygen (DO) concentration at or above 2.0 mg/L in the aeration process for biological nutrient removal (BNR). However, the adoption of operating at low DO in WWTP aeration systems has led to the improvement of process efficiency and reduced aeration energy requirements, making the transition to low DO favorable. Furthermore, as systems transition to oxygen-limiting conditions, the accuracy in DO measurements becomes increasingly important. Many plants use DO sensors to regularly control aeration processes, but their precision and accuracy at (ultra) low DO concentrations are less established. If a system lacks certainty in a DO measurement, both process optimization and BNR performance can become hindered. The research in this study evaluated various methods to validate low and ultra-low DO measurements for a BNR system. Pilot-scale and full-scale studies were conducted to assess phosphorus and nitrogen removal performance under these limiting DO conditions. Additionally, pilot-scale tests were conducted to evaluate DO sensor performance, compare sensor measurement methods, and determine practical approaches to verify DO concentrations under controlled conditions. Multiple methods were examined and applied over a range of operation conditions representative of wastewater treatment processes. The results from this work demonstrated that effective phosphorus removal can be achieved at DO concentrations significantly below conventional operating targets. PAO Ko values were observed at DO concentrations below 0.13 mg/L in batch tests. Additionally, significant differences in DO sensor performance were observed among measurement technologies, specifically within the ultra-low DO range (< 0.2 mg/L). Optical sensors generally displayed improved accuracy, precision, and stability compared to electrochemical sensors, with the PyroScience TROXROB10 optical sensor providing the most reliable measurements."],"dc:identifier":["9798193214670","https://digitalcommons.odu.edu/cee_etds/228"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Biological Nutrient Removal","Dissolved Oxygen","Phosphorus","Environmental Engineering"],"dc:title":["Validating Low Dissolved Oxygen Measurements to Improve Process Performance and Control"],"thesis:degree_discipline":["Civil & Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:34:25Z"}