{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:ece_etds-1342"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:ece_etds-1342","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Characterization and Quantum Efficiency Validation of Ingaas Linear Focal Plane Array","abstract":"A 1x1024 InGaAs linear hybrid focal plane array (FPA) with CMOS readout was characterized at room temperature to analyze its electrical and optical properties and to measure its performance parameters. The most important parameter of an FPA is the gain constant K, which allows conversion of the FPA output measurement unit from digital counts into the number of generated signal electrons. For FPAs with CMOS readout, the commonly used meanvariance method for determining K often underestimates its value. A more reliable method for finding K is the photon transfer technique, which is developed for FPAs with CCD readout. This technique is verified by applying it to a group of custom-designed Si CCDs. The photon transfer technique is then applied to the InGaAs FPA with CMOS readout to find its K-value. However, it was found that the background noise of the InGaAs FPA is excessively high up to saturation; thus another method using mean square error minimization is used in conjunction with the photon transfer technique. An experimental setup and procedure for measuring the signal and noise of the array associated with the camera at varying exposure level, exposure time, and radiation wavelength were constructed. The K-value of the InGaAs FPA was obtained including the read noise and full-well capacity. The responsivity, quantum efficiency, detectivity, dark current, and linearity were also obtained and analyzed. To validate the experimental data for quantum efficiency, a theoretical model of the quantum efficiency of the InGaAs photodetectors making up the FPA was constructed based on optical properties of InGaAs material.","abstract_html":"A 1x1024 InGaAs linear hybrid focal plane array (FPA) with CMOS readout was characterized at room temperature to analyze its electrical and optical properties and to measure its performance parameters. The most important parameter of an FPA is the gain constant K, which allows conversion of the FPA output measurement unit from digital counts into the number of generated signal electrons. For FPAs with CMOS readout, the commonly used meanvariance method for determining K often underestimates its value. A more reliable method for finding K is the photon transfer technique, which is developed for FPAs with CCD readout. This technique is verified by applying it to a group of custom-designed Si CCDs. The photon transfer technique is then applied to the InGaAs FPA with CMOS readout to find its K-value. However, it was found that the background noise of the InGaAs FPA is excessively high up to saturation; thus another method using mean square error minimization is used in conjunction with the photon transfer technique. An experimental setup and procedure for measuring the signal and noise of the array associated with the camera at varying exposure level, exposure time, and radiation wavelength were constructed. The K-value of the InGaAs FPA was obtained including the read noise and full-well capacity. The responsivity, quantum efficiency, detectivity, dark current, and linearity were also obtained and analyzed. To validate the experimental data for quantum efficiency, a theoretical model of the quantum efficiency of the InGaAs photodetectors making up the FPA was constructed based on optical properties of InGaAs material.","abstract_has_math":false,"creators":["Garcia, Christopher Salenga"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engineering","degree_department":null,"school":null,"contributors":["Hani Elsayed-Ali","Sacharia Albin","Helmut Baumgart","Nurul Abedkn","Tamer Refaat"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:31:47Z","subjects":["Indium arsenide","Gallium arsenide","Focal planes","Metal oxide semiconductors","Charge coupled devices","Electronic Devices and Semiconductor Manufacturing","Engineering Physics"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/ece_etds/349","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/ece_etds/349","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Aece_etds-1342","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Aece_etds-1342","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hani Elsayed-Ali","Sacharia Albin","Helmut Baumgart","Nurul Abedkn","Tamer Refaat"]},{"key":"dc:creator","label":"Author","values":["Garcia, Christopher Salenga"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-07-29T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-04-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Indium arsenide","Gallium arsenide","Focal planes","Metal oxide semiconductors","Charge coupled devices","Electronic Devices and Semiconductor Manufacturing","Engineering Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/ece_etds/349"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A 1x1024 InGaAs linear hybrid focal plane array (FPA) with CMOS readout was characterized at room temperature to analyze its electrical and optical properties and to measure its performance parameters. The most important parameter of an FPA is the gain constant K, which allows conversion of the FPA output measurement unit from digital counts into the number of generated signal electrons. For FPAs with CMOS readout, the commonly used meanvariance method for determining K often underestimates its value. A more reliable method for finding K is the photon transfer technique, which is developed for FPAs with CCD readout. This technique is verified by applying it to a group of custom-designed Si CCDs. The photon transfer technique is then applied to the InGaAs FPA with CMOS readout to find its K-value. However, it was found that the background noise of the InGaAs FPA is excessively high up to saturation; thus another method using mean square error minimization is used in conjunction with the photon transfer technique. An experimental setup and procedure for measuring the signal and noise of the array associated with the camera at varying exposure level, exposure time, and radiation wavelength were constructed. The K-value of the InGaAs FPA was obtained including the read noise and full-well capacity. The responsivity, quantum efficiency, detectivity, dark current, and linearity were also obtained and analyzed. To validate the experimental data for quantum efficiency, a theoretical model of the quantum efficiency of the InGaAs photodetectors making up the FPA was constructed based on optical properties of InGaAs material."]},{"key":"dc:title","label":"Title","values":["Characterization and Quantum Efficiency Validation of Ingaas Linear Focal Plane Array"]}]}],"canonical_facts":{"dc:contributor":["Hani Elsayed-Ali","Sacharia Albin","Helmut Baumgart","Nurul Abedkn","Tamer Refaat"],"dc:creator":["Garcia, Christopher Salenga"],"dc:date.available":["2024-07-29T07:00:00Z"],"dc:date.created":["2006-04-01T08:00:00Z"],"dc:description.abstract":["A 1x1024 InGaAs linear hybrid focal plane array (FPA) with CMOS readout was characterized at room temperature to analyze its electrical and optical properties and to measure its performance parameters. The most important parameter of an FPA is the gain constant K, which allows conversion of the FPA output measurement unit from digital counts into the number of generated signal electrons. For FPAs with CMOS readout, the commonly used meanvariance method for determining K often underestimates its value. A more reliable method for finding K is the photon transfer technique, which is developed for FPAs with CCD readout. This technique is verified by applying it to a group of custom-designed Si CCDs. The photon transfer technique is then applied to the InGaAs FPA with CMOS readout to find its K-value. However, it was found that the background noise of the InGaAs FPA is excessively high up to saturation; thus another method using mean square error minimization is used in conjunction with the photon transfer technique. An experimental setup and procedure for measuring the signal and noise of the array associated with the camera at varying exposure level, exposure time, and radiation wavelength were constructed. The K-value of the InGaAs FPA was obtained including the read noise and full-well capacity. The responsivity, quantum efficiency, detectivity, dark current, and linearity were also obtained and analyzed. To validate the experimental data for quantum efficiency, a theoretical model of the quantum efficiency of the InGaAs photodetectors making up the FPA was constructed based on optical properties of InGaAs material."],"dc:identifier":["https://digitalcommons.odu.edu/ece_etds/349"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Indium arsenide","Gallium arsenide","Focal planes","Metal oxide semiconductors","Charge coupled devices","Electronic Devices and Semiconductor Manufacturing","Engineering Physics"],"dc:title":["Characterization and Quantum Efficiency Validation of Ingaas Linear Focal Plane Array"],"thesis:degree_discipline":["Electrical & Computer Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:31:47Z"}