{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:ece_etds-1357"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:ece_etds-1357","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Frequency Response Enhancement of a Flow Sensor Using Diamond Thin Films Synthesized by Plasma CVD","abstract":"Theoretical modeling conducted previously in our Microelectronics Laboratory has shown that a layer of diamond film inserted between a metal film and a substrate will enhance the frequency response of a conventional thin film flow sensor. This thesis involved fabricating and testing a conventional thin film sensor of nickel on quartz (Ni/Q) and a diamond enhanced sensor (Ni/D/Q) for comparative frequency response analysis to validate the theory. Diamond films were grown onto quartz substrates using a microwave plasma enhanced chemical vapor deposition process. Conditions were established to synthesize continuous diamond films on quartz substrates. These films were characterized by scanning electron microscopy and Raman spectroscopy. The frequency response of the Ni/Q and Ni/D/Q sensors were measured using a constant temperature anemometer. The diamond enhanced sensor yielded a frequency response of 240 kHz compared to 100 kHz for the conventional thin film sensor, which is in agreement with the theoretically predicted results.","abstract_html":"Theoretical modeling conducted previously in our Microelectronics Laboratory has shown that a layer of diamond film inserted between a metal film and a substrate will enhance the frequency response of a conventional thin film flow sensor. This thesis involved fabricating and testing a conventional thin film sensor of nickel on quartz (Ni/Q) and a diamond enhanced sensor (Ni/D/Q) for comparative frequency response analysis to validate the theory. Diamond films were grown onto quartz substrates using a microwave plasma enhanced chemical vapor deposition process. Conditions were established to synthesize continuous diamond films on quartz substrates. These films were characterized by scanning electron microscopy and Raman spectroscopy. The frequency response of the Ni/Q and Ni/D/Q sensors were measured using a constant temperature anemometer. The diamond enhanced sensor yielded a frequency response of 240 kHz compared to 100 kHz for the conventional thin film sensor, which is in agreement with the theoretically predicted results.","abstract_has_math":false,"creators":["Hagwood, John Curren"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engineering","degree_department":null,"school":null,"contributors":["Sacharia Albin","Vishnu K. Lakdawala","Linda Vahala"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:31:47Z","subjects":["Diamond thin films","Frequency response","Thin-film circuits","Electrical and Electronics","Engineering Physics"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/ece_etds/354","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/ece_etds/354","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Aece_etds-1357","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sacharia Albin","Vishnu K. Lakdawala","Linda Vahala"]},{"key":"dc:creator","label":"Author","values":["Hagwood, John Curren"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-07-30T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1996-04-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Diamond thin films","Frequency response","Thin-film circuits","Electrical and Electronics","Engineering Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/ece_etds/354"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Theoretical modeling conducted previously in our Microelectronics Laboratory has shown that a layer of diamond film inserted between a metal film and a substrate will enhance the frequency response of a conventional thin film flow sensor. This thesis involved fabricating and testing a conventional thin film sensor of nickel on quartz (Ni/Q) and a diamond enhanced sensor (Ni/D/Q) for comparative frequency response analysis to validate the theory. Diamond films were grown onto quartz substrates using a microwave plasma enhanced chemical vapor deposition process. Conditions were established to synthesize continuous diamond films on quartz substrates. These films were characterized by scanning electron microscopy and Raman spectroscopy. The frequency response of the Ni/Q and Ni/D/Q sensors were measured using a constant temperature anemometer. The diamond enhanced sensor yielded a frequency response of 240 kHz compared to 100 kHz for the conventional thin film sensor, which is in agreement with the theoretically predicted results."]},{"key":"dc:title","label":"Title","values":["Frequency Response Enhancement of a Flow Sensor Using Diamond Thin Films Synthesized by Plasma CVD"]}]}],"canonical_facts":{"dc:contributor":["Sacharia Albin","Vishnu K. Lakdawala","Linda Vahala"],"dc:creator":["Hagwood, John Curren"],"dc:date.available":["2024-07-30T07:00:00Z"],"dc:date.created":["1996-04-01T08:00:00Z"],"dc:description.abstract":["Theoretical modeling conducted previously in our Microelectronics Laboratory has shown that a layer of diamond film inserted between a metal film and a substrate will enhance the frequency response of a conventional thin film flow sensor. This thesis involved fabricating and testing a conventional thin film sensor of nickel on quartz (Ni/Q) and a diamond enhanced sensor (Ni/D/Q) for comparative frequency response analysis to validate the theory. Diamond films were grown onto quartz substrates using a microwave plasma enhanced chemical vapor deposition process. Conditions were established to synthesize continuous diamond films on quartz substrates. These films were characterized by scanning electron microscopy and Raman spectroscopy. The frequency response of the Ni/Q and Ni/D/Q sensors were measured using a constant temperature anemometer. The diamond enhanced sensor yielded a frequency response of 240 kHz compared to 100 kHz for the conventional thin film sensor, which is in agreement with the theoretically predicted results."],"dc:identifier":["https://digitalcommons.odu.edu/ece_etds/354"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Diamond thin films","Frequency response","Thin-film circuits","Electrical and Electronics","Engineering Physics"],"dc:title":["Frequency Response Enhancement of a Flow Sensor Using Diamond Thin Films Synthesized by Plasma CVD"],"thesis:degree_discipline":["Electrical & Computer Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:31:47Z"}