{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:ece_etds-1418"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:ece_etds-1418","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Mitigation of Water Vapor Interference for Infrared Polarization-Modulated Gas Filter Correlation Radiometry","abstract":"Gas filter correlation radiometry (GFCR) is a high-resolution, high-specificity technique for sensing gaseous species. A variation of absorption spectroscopy, GFCR has a long-proven record on orbital platforms for quantitative measurements of atmospheric constituents, as well as common usage in ground-based sensing applications. PMGFCR (Polarization-modulated GFCR) is a recent refinement of the technique with several advantages over the traditional method, including reducing the number of photodetectors required, increased sensitivity, and elimination of moving parts. To date, no infrared remote sensors have successfully measured nitric oxide (NO) in vehicle exhaust due to spectral overlap by strong water vapor (H2Ov) absorption bands. The inherent specificity of PMGFCR provides sufficient suppression of H2Ov interference to measure vehicles with high NO emissions (l00's parts per million (ppm)). This thesis investigates optimization of the PMGFCR to further reduce H2Ov interference. We use a computer model to demonstrate that with careful optical filter selection, accurate measurements of NO are feasible with the PM-GFCR, and optimize a laboratory bench-top PM-GFCR system to verify the predictions made with the computer model. Typical measurement error due to transient water vapor may be reduced from over 300 ppm equivalent NO to as little as 2 ppm.","abstract_html":"Gas filter correlation radiometry (GFCR) is a high-resolution, high-specificity technique for sensing gaseous species. A variation of absorption spectroscopy, GFCR has a long-proven record on orbital platforms for quantitative measurements of atmospheric constituents, as well as common usage in ground-based sensing applications. PMGFCR (Polarization-modulated GFCR) is a recent refinement of the technique with several advantages over the traditional method, including reducing the number of photodetectors required, increased sensitivity, and elimination of moving parts. To date, no infrared remote sensors have successfully measured nitric oxide (NO) in vehicle exhaust due to spectral overlap by strong water vapor (H2Ov) absorption bands. The inherent specificity of PMGFCR provides sufficient suppression of H2Ov interference to measure vehicles with high NO emissions (l00&#x27;s parts per million (ppm)). This thesis investigates optimization of the PMGFCR to further reduce H2Ov interference. We use a computer model to demonstrate that with careful optical filter selection, accurate measurements of NO are feasible with the PM-GFCR, and optimize a laboratory bench-top PM-GFCR system to verify the predictions made with the computer model. Typical measurement error due to transient water vapor may be reduced from over 300 ppm equivalent NO to as little as 2 ppm.","abstract_has_math":false,"creators":["Lockwood, David K."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engineering","degree_department":null,"school":null,"contributors":["Amin N. Dharamsi","Ravindra P. Joshi","Glen W. Sachse"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:31:47Z","subjects":["Absorbance scale","Air pollution","Spectroscopy","Water vapor","Atmospheric Sciences","Electromagnetics and Photonics","Engineering Physics","Meteorology"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/ece_etds/418","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/ece_etds/418","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Aece_etds-1418","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Aece_etds-1418","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Amin N. Dharamsi","Ravindra P. Joshi","Glen W. Sachse"]},{"key":"dc:creator","label":"Author","values":["Lockwood, David K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-08T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2001-04-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Absorbance scale","Air pollution","Spectroscopy","Water vapor","Atmospheric Sciences","Electromagnetics and Photonics","Engineering Physics","Meteorology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/ece_etds/418"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Gas filter correlation radiometry (GFCR) is a high-resolution, high-specificity technique for sensing gaseous species. A variation of absorption spectroscopy, GFCR has a long-proven record on orbital platforms for quantitative measurements of atmospheric constituents, as well as common usage in ground-based sensing applications. PMGFCR (Polarization-modulated GFCR) is a recent refinement of the technique with several advantages over the traditional method, including reducing the number of photodetectors required, increased sensitivity, and elimination of moving parts. To date, no infrared remote sensors have successfully measured nitric oxide (NO) in vehicle exhaust due to spectral overlap by strong water vapor (H2Ov) absorption bands. The inherent specificity of PMGFCR provides sufficient suppression of H2Ov interference to measure vehicles with high NO emissions (l00's parts per million (ppm)). This thesis investigates optimization of the PMGFCR to further reduce H2Ov interference. We use a computer model to demonstrate that with careful optical filter selection, accurate measurements of NO are feasible with the PM-GFCR, and optimize a laboratory bench-top PM-GFCR system to verify the predictions made with the computer model. Typical measurement error due to transient water vapor may be reduced from over 300 ppm equivalent NO to as little as 2 ppm."]},{"key":"dc:title","label":"Title","values":["Mitigation of Water Vapor Interference for Infrared Polarization-Modulated Gas Filter Correlation Radiometry"]}]}],"canonical_facts":{"dc:contributor":["Amin N. Dharamsi","Ravindra P. Joshi","Glen W. Sachse"],"dc:creator":["Lockwood, David K."],"dc:date.available":["2024-08-08T07:00:00Z"],"dc:date.created":["2001-04-01T08:00:00Z"],"dc:description.abstract":["Gas filter correlation radiometry (GFCR) is a high-resolution, high-specificity technique for sensing gaseous species. A variation of absorption spectroscopy, GFCR has a long-proven record on orbital platforms for quantitative measurements of atmospheric constituents, as well as common usage in ground-based sensing applications. PMGFCR (Polarization-modulated GFCR) is a recent refinement of the technique with several advantages over the traditional method, including reducing the number of photodetectors required, increased sensitivity, and elimination of moving parts. To date, no infrared remote sensors have successfully measured nitric oxide (NO) in vehicle exhaust due to spectral overlap by strong water vapor (H2Ov) absorption bands. The inherent specificity of PMGFCR provides sufficient suppression of H2Ov interference to measure vehicles with high NO emissions (l00's parts per million (ppm)). This thesis investigates optimization of the PMGFCR to further reduce H2Ov interference. We use a computer model to demonstrate that with careful optical filter selection, accurate measurements of NO are feasible with the PM-GFCR, and optimize a laboratory bench-top PM-GFCR system to verify the predictions made with the computer model. Typical measurement error due to transient water vapor may be reduced from over 300 ppm equivalent NO to as little as 2 ppm."],"dc:identifier":["https://digitalcommons.odu.edu/ece_etds/418"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Absorbance scale","Air pollution","Spectroscopy","Water vapor","Atmospheric Sciences","Electromagnetics and Photonics","Engineering Physics","Meteorology"],"dc:title":["Mitigation of Water Vapor Interference for Infrared Polarization-Modulated Gas Filter Correlation Radiometry"],"thesis:degree_discipline":["Electrical & Computer Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:31:47Z"}