{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:hms_etds-1034"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:hms_etds-1034","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Determining the Validity of a New Cycle Ergometer Protocol for Estimating VO(2) Max","abstract":"The current American College of Sports Medicine (ACSM) submaximal cycle ergometer protocol has been evaluated by several researchers for its validity in estimating maximal oxygen consumption (VO2max). It has been found that the ACSM protocol overestimates VO2max by 28% on average (Swain and Wright, 1997). It is felt that the short stage duration, only 3 minutes, of the ACSM protocol is largely responsible for this overestimation. The new submaximal cycle ergometer protocol evaluated here utilizes a 6-minute stage in an attempt to reduce the overestimation of VO2max while increasing the overall test validity. A regression performed on actual VO2max vs. the VO2 Reserve method of VO2max estimation showed an r-value of 0.89, and an SEE of 3.97 ml·min−1.kg−1. The mean value of actual VO2max was 36.9 ± 8.8 ml·min−1. kg−1, while that for the VO2R estimated VO2max was 36.7 ± 8.4 ml·min−1.kg −1. A regression performed on actual VO2max vs. the Astrand estimate of VO2max showed an r-value of 0.82, and an SEE of 5.09 ml·min−1.kg−1. The mean value for the Astrand estimate of VO2max was 39.8 ± 11.1 ml·min−1.kg−1.","abstract_html":"The current American College of Sports Medicine (ACSM) submaximal cycle ergometer protocol has been evaluated by several researchers for its validity in estimating maximal oxygen consumption (VO2max). It has been found that the ACSM protocol overestimates VO2max by 28% on average (Swain and Wright, 1997). It is felt that the short stage duration, only 3 minutes, of the ACSM protocol is largely responsible for this overestimation. The new submaximal cycle ergometer protocol evaluated here utilizes a 6-minute stage in an attempt to reduce the overestimation of VO2max while increasing the overall test validity. A regression performed on actual VO2max vs. the VO2 Reserve method of VO2max estimation showed an r-value of 0.89, and an SEE of 3.97 ml·min−1.kg−1. The mean value of actual VO2max was 36.9 ± 8.8 ml·min−1. kg−1, while that for the VO2R estimated VO2max was 36.7 ± 8.4 ml·min−1.kg −1. A regression performed on actual VO2max vs. the Astrand estimate of VO2max showed an r-value of 0.82, and an SEE of 5.09 ml·min−1.kg−1. The mean value for the Astrand estimate of VO2max was 39.8 ± 11.1 ml·min−1.kg−1.","abstract_has_math":false,"creators":["Parrott, James Allen"],"institution":null,"degree_name":"Master of Science in Education (MSEd)","degree_level":"Thesis","degree_discipline":"Human Movement Sciences","degree_department":null,"school":null,"contributors":["David P. Swain","J. David Branch","Elizabeth Dowling"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:08:33Z","subjects":["Physical fitness","Measurement","Testing","Oxygen","Health and Physical Education","Sports Medicine"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["9780496216888"],"render_values":[{"text":"9780496216888","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/hms_etds/32","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/hms_etds/32","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Ahms_etds-1034","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Ahms_etds-1034","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David P. Swain","J. David Branch","Elizabeth Dowling"]},{"key":"dc:creator","label":"Author","values":["Parrott, James Allen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-07-02T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2003-04-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Human Movement Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Education (MSEd)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physical fitness","Measurement","Testing","Oxygen","Health and Physical Education","Sports Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["9780496216888","https://digitalcommons.odu.edu/hms_etds/32"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The current American College of Sports Medicine (ACSM) submaximal cycle ergometer protocol has been evaluated by several researchers for its validity in estimating maximal oxygen consumption (VO2max). It has been found that the ACSM protocol overestimates VO2max by 28% on average (Swain and Wright, 1997). It is felt that the short stage duration, only 3 minutes, of the ACSM protocol is largely responsible for this overestimation. The new submaximal cycle ergometer protocol evaluated here utilizes a 6-minute stage in an attempt to reduce the overestimation of VO2max while increasing the overall test validity. A regression performed on actual VO2max vs. the VO2 Reserve method of VO2max estimation showed an r-value of 0.89, and an SEE of 3.97 ml·min−1.kg−1. The mean value of actual VO2max was 36.9 ± 8.8 ml·min−1. kg−1, while that for the VO2R estimated VO2max was 36.7 ± 8.4 ml·min−1.kg −1. A regression performed on actual VO2max vs. the Astrand estimate of VO2max showed an r-value of 0.82, and an SEE of 5.09 ml·min−1.kg−1. The mean value for the Astrand estimate of VO2max was 39.8 ± 11.1 ml·min−1.kg−1."]},{"key":"dc:title","label":"Title","values":["Determining the Validity of a New Cycle Ergometer Protocol for Estimating VO(2) Max"]}]}],"canonical_facts":{"dc:contributor":["David P. Swain","J. David Branch","Elizabeth Dowling"],"dc:creator":["Parrott, James Allen"],"dc:date.available":["2019-07-02T07:00:00Z"],"dc:date.created":["2003-04-01T08:00:00Z"],"dc:description.abstract":["The current American College of Sports Medicine (ACSM) submaximal cycle ergometer protocol has been evaluated by several researchers for its validity in estimating maximal oxygen consumption (VO2max). It has been found that the ACSM protocol overestimates VO2max by 28% on average (Swain and Wright, 1997). It is felt that the short stage duration, only 3 minutes, of the ACSM protocol is largely responsible for this overestimation. The new submaximal cycle ergometer protocol evaluated here utilizes a 6-minute stage in an attempt to reduce the overestimation of VO2max while increasing the overall test validity. A regression performed on actual VO2max vs. the VO2 Reserve method of VO2max estimation showed an r-value of 0.89, and an SEE of 3.97 ml·min−1.kg−1. The mean value of actual VO2max was 36.9 ± 8.8 ml·min−1. kg−1, while that for the VO2R estimated VO2max was 36.7 ± 8.4 ml·min−1.kg −1. A regression performed on actual VO2max vs. the Astrand estimate of VO2max showed an r-value of 0.82, and an SEE of 5.09 ml·min−1.kg−1. The mean value for the Astrand estimate of VO2max was 39.8 ± 11.1 ml·min−1.kg−1."],"dc:identifier":["9780496216888","https://digitalcommons.odu.edu/hms_etds/32"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Physical fitness","Measurement","Testing","Oxygen","Health and Physical Education","Sports Medicine"],"dc:title":["Determining the Validity of a New Cycle Ergometer Protocol for Estimating VO(2) Max"],"thesis:degree_discipline":["Human Movement Sciences"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Education (MSEd)"]},"updated_at":"2026-11-27T04:08:33Z"}