{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:mae_etds-1314"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:mae_etds-1314","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Thermal Contact Resistance Measurement and Related Uncertainties","abstract":"Thermal contact resistance is an important parameter in detailed thermal analysis and design of aerospace systems. The ability to determine thermal contact resistance reliably can have a significant impact on the fidelity of thermal models—particularly for space applications. The 2004 NASA Langley Research Center thermal contact resistance test apparatus has been employed to evaluate two methods for inferring estimated interface surface temperatures so that thermal contact resistance can be calculated more accurately. The traditional method of extrapolation is a steady-state approach, while the new method utilizes inverse heat transfer techniques to account for inherent unsteadiness in these quasi-steady-state measurements. The understanding of the uncertainty for the empirical data has helped quantify the reliability of thermal contact resistance. As a result, this study includes a thorough uncertainty analysis so that the two methods could be compared.","abstract_html":"Thermal contact resistance is an important parameter in detailed thermal analysis and design of aerospace systems. The ability to determine thermal contact resistance reliably can have a significant impact on the fidelity of thermal models—particularly for space applications. The 2004 NASA Langley Research Center thermal contact resistance test apparatus has been employed to evaluate two methods for inferring estimated interface surface temperatures so that thermal contact resistance can be calculated more accurately. The traditional method of extrapolation is a steady-state approach, while the new method utilizes inverse heat transfer techniques to account for inherent unsteadiness in these quasi-steady-state measurements. The understanding of the uncertainty for the empirical data has helped quantify the reliability of thermal contact resistance. As a result, this study includes a thorough uncertainty analysis so that the two methods could be compared.","abstract_has_math":false,"creators":["Stark, Amanda Elizabeth"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical & Aerospace Engineering","degree_department":null,"school":null,"contributors":["Robert Ash","Kamran Daryabeigi","Arthur Taylor"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:10:24Z","subjects":["Heat transfer","Inverse heat transfer method","Thermal contact resistance","Uncertainty analysis","Aerospace Engineering","Mechanical Engineering"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["9798641317649"],"render_values":[{"text":"9798641317649","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/mae_etds/314","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/mae_etds/314","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Amae_etds-1314","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Amae_etds-1314","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Robert Ash","Kamran Daryabeigi","Arthur Taylor"]},{"key":"dc:creator","label":"Author","values":["Stark, Amanda Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-07-10T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-04-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical & Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Heat transfer","Inverse heat transfer method","Thermal contact resistance","Uncertainty analysis","Aerospace Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["9798641317649","https://digitalcommons.odu.edu/mae_etds/314"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Thermal contact resistance is an important parameter in detailed thermal analysis and design of aerospace systems. The ability to determine thermal contact resistance reliably can have a significant impact on the fidelity of thermal models—particularly for space applications. The 2004 NASA Langley Research Center thermal contact resistance test apparatus has been employed to evaluate two methods for inferring estimated interface surface temperatures so that thermal contact resistance can be calculated more accurately. The traditional method of extrapolation is a steady-state approach, while the new method utilizes inverse heat transfer techniques to account for inherent unsteadiness in these quasi-steady-state measurements. The understanding of the uncertainty for the empirical data has helped quantify the reliability of thermal contact resistance. As a result, this study includes a thorough uncertainty analysis so that the two methods could be compared."]},{"key":"dc:title","label":"Title","values":["Thermal Contact Resistance Measurement and Related Uncertainties"]}]}],"canonical_facts":{"dc:contributor":["Robert Ash","Kamran Daryabeigi","Arthur Taylor"],"dc:creator":["Stark, Amanda Elizabeth"],"dc:date.available":["2020-07-10T07:00:00Z"],"dc:date.created":["2020-04-01T07:00:00Z"],"dc:description.abstract":["Thermal contact resistance is an important parameter in detailed thermal analysis and design of aerospace systems. The ability to determine thermal contact resistance reliably can have a significant impact on the fidelity of thermal models—particularly for space applications. The 2004 NASA Langley Research Center thermal contact resistance test apparatus has been employed to evaluate two methods for inferring estimated interface surface temperatures so that thermal contact resistance can be calculated more accurately. The traditional method of extrapolation is a steady-state approach, while the new method utilizes inverse heat transfer techniques to account for inherent unsteadiness in these quasi-steady-state measurements. The understanding of the uncertainty for the empirical data has helped quantify the reliability of thermal contact resistance. As a result, this study includes a thorough uncertainty analysis so that the two methods could be compared."],"dc:identifier":["9798641317649","https://digitalcommons.odu.edu/mae_etds/314"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Heat transfer","Inverse heat transfer method","Thermal contact resistance","Uncertainty analysis","Aerospace Engineering","Mechanical Engineering"],"dc:title":["Thermal Contact Resistance Measurement and Related Uncertainties"],"thesis:degree_discipline":["Mechanical & Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:10:24Z"}