{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:mae_etds-1437"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:mae_etds-1437","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"An Experimental and Analytical Investigation of Friction Factors for Fully Developed Flow in Internally Finned Triangular Ducts","abstract":"Friction factors for fully-developed flow in triangular ducts with fins of various sizes are investigated for Reynolds numbers ranging from 150 to 90,000. Two triangular ducts having apex angles of 60 and 38.8 degrees are studied. Results are presented in the form of standard plots of friction factor as a function of Reynolds number. Friction factor values for the smooth triangular-duct cases are in good agreement with the existing results. For the finned-duct cases, the fully developed axial-velocity profiles in laminar flow are determined by solving the x-momentum equation iteratively by the Gauss-Seidel finite difference technique. The theoretically determined friction factors for these cases are in good agreement with the experimental values of friction factors based on pressure drop measurements.","abstract_html":"Friction factors for fully-developed flow in triangular ducts with fins of various sizes are investigated for Reynolds numbers ranging from 150 to 90,000. Two triangular ducts having apex angles of 60 and 38.8 degrees are studied. Results are presented in the form of standard plots of friction factor as a function of Reynolds number. Friction factor values for the smooth triangular-duct cases are in good agreement with the existing results. For the finned-duct cases, the fully developed axial-velocity profiles in laminar flow are determined by solving the x-momentum equation iteratively by the Gauss-Seidel finite difference technique. The theoretically determined friction factors for these cases are in good agreement with the experimental values of friction factors based on pressure drop measurements.","abstract_has_math":false,"creators":["Chegini, Hoshang"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical & Aerospace Engineering","degree_department":null,"school":null,"contributors":["Sushil K. Chaturvedi","Oktay Baysal","Gregory V. Selby"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:26Z","subjects":["Friction","Reynolds number","Aerospace Engineering"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/mae_etds/424","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/mae_etds/424","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Amae_etds-1437","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Amae_etds-1437","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sushil K. Chaturvedi","Oktay Baysal","Gregory V. Selby"]},{"key":"dc:creator","label":"Author","values":["Chegini, Hoshang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-08T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1984-07-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical & Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Friction","Reynolds number","Aerospace Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/mae_etds/424"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Friction factors for fully-developed flow in triangular ducts with fins of various sizes are investigated for Reynolds numbers ranging from 150 to 90,000. Two triangular ducts having apex angles of 60 and 38.8 degrees are studied. Results are presented in the form of standard plots of friction factor as a function of Reynolds number. Friction factor values for the smooth triangular-duct cases are in good agreement with the existing results. For the finned-duct cases, the fully developed axial-velocity profiles in laminar flow are determined by solving the x-momentum equation iteratively by the Gauss-Seidel finite difference technique. The theoretically determined friction factors for these cases are in good agreement with the experimental values of friction factors based on pressure drop measurements."]},{"key":"dc:title","label":"Title","values":["An Experimental and Analytical Investigation of Friction Factors for Fully Developed Flow in Internally Finned Triangular Ducts"]}]}],"canonical_facts":{"dc:contributor":["Sushil K. Chaturvedi","Oktay Baysal","Gregory V. Selby"],"dc:creator":["Chegini, Hoshang"],"dc:date.available":["2025-01-08T08:00:00Z"],"dc:date.created":["1984-07-01T07:00:00Z"],"dc:description.abstract":["Friction factors for fully-developed flow in triangular ducts with fins of various sizes are investigated for Reynolds numbers ranging from 150 to 90,000. Two triangular ducts having apex angles of 60 and 38.8 degrees are studied. Results are presented in the form of standard plots of friction factor as a function of Reynolds number. Friction factor values for the smooth triangular-duct cases are in good agreement with the existing results. For the finned-duct cases, the fully developed axial-velocity profiles in laminar flow are determined by solving the x-momentum equation iteratively by the Gauss-Seidel finite difference technique. The theoretically determined friction factors for these cases are in good agreement with the experimental values of friction factors based on pressure drop measurements."],"dc:identifier":["https://digitalcommons.odu.edu/mae_etds/424"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Friction","Reynolds number","Aerospace Engineering"],"dc:title":["An Experimental and Analytical Investigation of Friction Factors for Fully Developed Flow in Internally Finned Triangular Ducts"],"thesis:degree_discipline":["Mechanical & Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:26Z"}