{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:mae_etds-1508"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:mae_etds-1508","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Analysis of a Direct Expansion Solar-Assisted Heat Pump Using Different Refrigerants","abstract":"A direct expansion solar-assisted heat pump, the components of which are properly matched for a specified ambient condition characterized by geographical location, has been analyzed. The steady state energy equation across the collector is solved for several refrigerants for two configurations; bare collector and one-cover collector. The REFPROP computer program, developed by the National Institute of Science and Technology, is used to predict refrigerant properties that are used in the steady state energy balance. The thermal performance as characterized by the coefficient of performance (COPn) is determined for a variety of refrigerants. A graphical procedure is developed for sizing of solar collector area and heat pump compressor displacement capacity for two configurations that use a glass cover and a bare collector, respectively. The effects of using different refrigerants on system thermal performance are analyzed. The performance degradation due to mandated switching from refrigerant R-12 to hydro-fluoro-carbon refrigerants and refrigerant blends is investigated.","abstract_html":"A direct expansion solar-assisted heat pump, the components of which are properly matched for a specified ambient condition characterized by geographical location, has been analyzed. The steady state energy equation across the collector is solved for several refrigerants for two configurations; bare collector and one-cover collector. The REFPROP computer program, developed by the National Institute of Science and Technology, is used to predict refrigerant properties that are used in the steady state energy balance. The thermal performance as characterized by the coefficient of performance (COPn) is determined for a variety of refrigerants. A graphical procedure is developed for sizing of solar collector area and heat pump compressor displacement capacity for two configurations that use a glass cover and a bare collector, respectively. The effects of using different refrigerants on system thermal performance are analyzed. The performance degradation due to mandated switching from refrigerant R-12 to hydro-fluoro-carbon refrigerants and refrigerant blends is investigated.","abstract_has_math":false,"creators":["Gorozabel Chata, Francis Benjamin"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical & Aerospace Engineering","degree_department":null,"school":null,"contributors":["Sushil K. Chaturvedi","Surendra N. Tiwari","Taj O. Mohieldin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:35Z","subjects":["Heat pumps","Refrigerants","Soler energy","Mechanical Engineering"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/mae_etds/517","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/mae_etds/517","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Amae_etds-1508","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Amae_etds-1508","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sushil K. Chaturvedi","Surendra N. Tiwari","Taj O. Mohieldin"]},{"key":"dc:creator","label":"Author","values":["Gorozabel Chata, Francis Benjamin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-14T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2002-04-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical & Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Heat pumps","Refrigerants","Soler energy","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/mae_etds/517"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A direct expansion solar-assisted heat pump, the components of which are properly matched for a specified ambient condition characterized by geographical location, has been analyzed. The steady state energy equation across the collector is solved for several refrigerants for two configurations; bare collector and one-cover collector. The REFPROP computer program, developed by the National Institute of Science and Technology, is used to predict refrigerant properties that are used in the steady state energy balance. The thermal performance as characterized by the coefficient of performance (COPn) is determined for a variety of refrigerants. A graphical procedure is developed for sizing of solar collector area and heat pump compressor displacement capacity for two configurations that use a glass cover and a bare collector, respectively. The effects of using different refrigerants on system thermal performance are analyzed. The performance degradation due to mandated switching from refrigerant R-12 to hydro-fluoro-carbon refrigerants and refrigerant blends is investigated."]},{"key":"dc:title","label":"Title","values":["Analysis of a Direct Expansion Solar-Assisted Heat Pump Using Different Refrigerants"]}]}],"canonical_facts":{"dc:contributor":["Sushil K. Chaturvedi","Surendra N. Tiwari","Taj O. Mohieldin"],"dc:creator":["Gorozabel Chata, Francis Benjamin"],"dc:date.available":["2025-01-14T08:00:00Z"],"dc:date.created":["2002-04-01T08:00:00Z"],"dc:description.abstract":["A direct expansion solar-assisted heat pump, the components of which are properly matched for a specified ambient condition characterized by geographical location, has been analyzed. The steady state energy equation across the collector is solved for several refrigerants for two configurations; bare collector and one-cover collector. The REFPROP computer program, developed by the National Institute of Science and Technology, is used to predict refrigerant properties that are used in the steady state energy balance. The thermal performance as characterized by the coefficient of performance (COPn) is determined for a variety of refrigerants. A graphical procedure is developed for sizing of solar collector area and heat pump compressor displacement capacity for two configurations that use a glass cover and a bare collector, respectively. The effects of using different refrigerants on system thermal performance are analyzed. The performance degradation due to mandated switching from refrigerant R-12 to hydro-fluoro-carbon refrigerants and refrigerant blends is investigated."],"dc:identifier":["https://digitalcommons.odu.edu/mae_etds/517"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Heat pumps","Refrigerants","Soler energy","Mechanical Engineering"],"dc:title":["Analysis of a Direct Expansion Solar-Assisted Heat Pump Using Different Refrigerants"],"thesis:degree_discipline":["Mechanical & Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:35Z"}