{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:mae_etds-1712"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:mae_etds-1712","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Experimental Study of the Frequency Response of a Hot Film Anemometer","abstract":"This endeavor was motivated by the need to accurately quantify wind tunnel turbulence, a component of flow quality. The use of spheres and cones to find a turbulence correction factor has been mentioned in the literature but these methods are indirect approaches. To measure the amplitude and spectra of the velocity fluctuations, the hot wire anemometer is the only reliable instrument. A fiber-film sensor, which is similar in operation but with more mechanical rigidity, may be preferred over a hot wire owing to its robustness. In this work, the frequency response characteristics of the hot fiber-film sensor are studied. The sensor was tested in a grid generated turbulent flow, which was nearly homogenous and isotropic, over a large speed range (20-110 mis) and at five different overheat ratios (1.2, 1.3, 1.4, 1.6 and 1.7). Power spectra of the turbulence were plotted and compared with the power spectra obtained by a conventional hot wire anemometer at the same flow conditions and a overheat ratio of 1.7. This comparison yielded a set of relative response plots that were considered to be indicative of the frequency response of the hot film circuit. The hot wire response was assumed to be correct and was used to estimate the transfer function of the hot film. The transfer function of the hot film circuit was found to be changing with speed and overheat ratio and further investigation is required into this behavior. The usable bandwidth of the hot film is typically inferior to the hot wire.","abstract_html":"This endeavor was motivated by the need to accurately quantify wind tunnel turbulence, a component of flow quality. The use of spheres and cones to find a turbulence correction factor has been mentioned in the literature but these methods are indirect approaches. To measure the amplitude and spectra of the velocity fluctuations, the hot wire anemometer is the only reliable instrument. A fiber-film sensor, which is similar in operation but with more mechanical rigidity, may be preferred over a hot wire owing to its robustness. In this work, the frequency response characteristics of the hot fiber-film sensor are studied. The sensor was tested in a grid generated turbulent flow, which was nearly homogenous and isotropic, over a large speed range (20-110 mis) and at five different overheat ratios (1.2, 1.3, 1.4, 1.6 and 1.7). Power spectra of the turbulence were plotted and compared with the power spectra obtained by a conventional hot wire anemometer at the same flow conditions and a overheat ratio of 1.7. This comparison yielded a set of relative response plots that were considered to be indicative of the frequency response of the hot film circuit. The hot wire response was assumed to be correct and was used to estimate the transfer function of the hot film. The transfer function of the hot film circuit was found to be changing with speed and overheat ratio and further investigation is required into this behavior. The usable bandwidth of the hot film is typically inferior to the hot wire.","abstract_has_math":false,"creators":["Tamhane, Ashish"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical & Aerospace Engineering","degree_department":null,"school":null,"contributors":["Colin P. Britcher","Drew Landman","Robert L. Ash"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:35Z","subjects":["Wind tunnels","Turbulence","Hot-wire anemometer","Aerospace Engineering"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/mae_etds/702","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/mae_etds/702","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Amae_etds-1712","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Amae_etds-1712","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Colin P. Britcher","Drew Landman","Robert L. Ash"]},{"key":"dc:creator","label":"Author","values":["Tamhane, Ashish"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-03-06T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2008-10-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical & Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wind tunnels","Turbulence","Hot-wire anemometer","Aerospace Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/mae_etds/702"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This endeavor was motivated by the need to accurately quantify wind tunnel turbulence, a component of flow quality. The use of spheres and cones to find a turbulence correction factor has been mentioned in the literature but these methods are indirect approaches. To measure the amplitude and spectra of the velocity fluctuations, the hot wire anemometer is the only reliable instrument. A fiber-film sensor, which is similar in operation but with more mechanical rigidity, may be preferred over a hot wire owing to its robustness. In this work, the frequency response characteristics of the hot fiber-film sensor are studied. The sensor was tested in a grid generated turbulent flow, which was nearly homogenous and isotropic, over a large speed range (20-110 mis) and at five different overheat ratios (1.2, 1.3, 1.4, 1.6 and 1.7). Power spectra of the turbulence were plotted and compared with the power spectra obtained by a conventional hot wire anemometer at the same flow conditions and a overheat ratio of 1.7. This comparison yielded a set of relative response plots that were considered to be indicative of the frequency response of the hot film circuit. The hot wire response was assumed to be correct and was used to estimate the transfer function of the hot film. The transfer function of the hot film circuit was found to be changing with speed and overheat ratio and further investigation is required into this behavior. The usable bandwidth of the hot film is typically inferior to the hot wire."]},{"key":"dc:title","label":"Title","values":["Experimental Study of the Frequency Response of a Hot Film Anemometer"]}]}],"canonical_facts":{"dc:contributor":["Colin P. Britcher","Drew Landman","Robert L. Ash"],"dc:creator":["Tamhane, Ashish"],"dc:date.available":["2025-03-06T08:00:00Z"],"dc:date.created":["2008-10-01T07:00:00Z"],"dc:description.abstract":["This endeavor was motivated by the need to accurately quantify wind tunnel turbulence, a component of flow quality. The use of spheres and cones to find a turbulence correction factor has been mentioned in the literature but these methods are indirect approaches. To measure the amplitude and spectra of the velocity fluctuations, the hot wire anemometer is the only reliable instrument. A fiber-film sensor, which is similar in operation but with more mechanical rigidity, may be preferred over a hot wire owing to its robustness. In this work, the frequency response characteristics of the hot fiber-film sensor are studied. The sensor was tested in a grid generated turbulent flow, which was nearly homogenous and isotropic, over a large speed range (20-110 mis) and at five different overheat ratios (1.2, 1.3, 1.4, 1.6 and 1.7). Power spectra of the turbulence were plotted and compared with the power spectra obtained by a conventional hot wire anemometer at the same flow conditions and a overheat ratio of 1.7. This comparison yielded a set of relative response plots that were considered to be indicative of the frequency response of the hot film circuit. The hot wire response was assumed to be correct and was used to estimate the transfer function of the hot film. The transfer function of the hot film circuit was found to be changing with speed and overheat ratio and further investigation is required into this behavior. The usable bandwidth of the hot film is typically inferior to the hot wire."],"dc:identifier":["https://digitalcommons.odu.edu/mae_etds/702"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Wind tunnels","Turbulence","Hot-wire anemometer","Aerospace Engineering"],"dc:title":["Experimental Study of the Frequency Response of a Hot Film Anemometer"],"thesis:degree_discipline":["Mechanical & Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:35Z"}