{"id":{"repo_id":"odu","oai_identifier":"oai:digitalcommons.odu.edu:mae_etds-1742"},"canonical_url":"https://search.ndltd.org/etd/odu/oai:digitalcommons.odu.edu:mae_etds-1742","repository":{"repo_id":"odu","name":"Old Dominion University","base_url":"https://digitalcommons.odu.edu/do/oai/"},"display":{"title":"Study of Surface Heat Exchangers for High-Altitude Atmospheric Research Aircraft","abstract":"A flush-mounted heat exchanger concept, using the wing surface to dissipate heat, is investigated as a lower drag alternative to conventional ducted plate-fin radiators. A feasibility analysis is made for an unmanned high-altitude aircraft which will reach altitudes up to 25 kilometers. A computer code is used to calculate approximate heat transfer coefficients over the airfoil's surface. A model is tested in the Old Dominion University subsonic wind tunnel to verify the results of the computer code. The results indicate that a flush mounted heat exchanger design is able to provide 20 to 100 percent of the required heat dissipation at 25 kilometers altitude, depending upon which areas of the wing are considered usable. The attainable dissipation increases with decreasing altitude and with increasing angle of attack. The effect of surface heating on the boundary layer development is discussed. It is concluded that flush-mounted heat exchangers are a viable design option and are worthy of further study.","abstract_html":"A flush-mounted heat exchanger concept, using the wing surface to dissipate heat, is investigated as a lower drag alternative to conventional ducted plate-fin radiators. A feasibility analysis is made for an unmanned high-altitude aircraft which will reach altitudes up to 25 kilometers. A computer code is used to calculate approximate heat transfer coefficients over the airfoil&#x27;s surface. A model is tested in the Old Dominion University subsonic wind tunnel to verify the results of the computer code. The results indicate that a flush mounted heat exchanger design is able to provide 20 to 100 percent of the required heat dissipation at 25 kilometers altitude, depending upon which areas of the wing are considered usable. The attainable dissipation increases with decreasing altitude and with increasing angle of attack. The effect of surface heating on the boundary layer development is discussed. It is concluded that flush-mounted heat exchangers are a viable design option and are worthy of further study.","abstract_has_math":false,"creators":["Wang, Te-Kang"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Mechanical & Aerospace Engineering","degree_department":null,"school":null,"contributors":["Colin P. Britcher","Robert L. Ash","A. Sidney Roberts"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T04:11:35Z","subjects":["Air ducts","Aerodynamic heating","Heat exchanges","Aerodynamics and Fluid Mechanics","Aeronautical Vehicles"],"languages":[],"rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.odu.edu/mae_etds/735","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.odu.edu/mae_etds/735","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aodu%3Aoai%3Adigitalcommons.odu.edu%3Amae_etds-1742","prefix":"oai_dc"},"source_record":{"url":"https://digitalcommons.odu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.odu.edu%3Amae_etds-1742","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Colin P. Britcher","Robert L. Ash","A. Sidney Roberts"]},{"key":"dc:creator","label":"Author","values":["Wang, Te-Kang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-03-13T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1996-04-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical & Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air ducts","Aerodynamic heating","Heat exchanges","Aerodynamics and Fluid Mechanics","Aeronautical Vehicles"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.odu.edu/mae_etds/735"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A flush-mounted heat exchanger concept, using the wing surface to dissipate heat, is investigated as a lower drag alternative to conventional ducted plate-fin radiators. A feasibility analysis is made for an unmanned high-altitude aircraft which will reach altitudes up to 25 kilometers. A computer code is used to calculate approximate heat transfer coefficients over the airfoil's surface. A model is tested in the Old Dominion University subsonic wind tunnel to verify the results of the computer code. The results indicate that a flush mounted heat exchanger design is able to provide 20 to 100 percent of the required heat dissipation at 25 kilometers altitude, depending upon which areas of the wing are considered usable. The attainable dissipation increases with decreasing altitude and with increasing angle of attack. The effect of surface heating on the boundary layer development is discussed. It is concluded that flush-mounted heat exchangers are a viable design option and are worthy of further study."]},{"key":"dc:title","label":"Title","values":["Study of Surface Heat Exchangers for High-Altitude Atmospheric Research Aircraft"]}]}],"canonical_facts":{"dc:contributor":["Colin P. Britcher","Robert L. Ash","A. Sidney Roberts"],"dc:creator":["Wang, Te-Kang"],"dc:date.available":["2025-03-13T07:00:00Z"],"dc:date.created":["1996-04-01T08:00:00Z"],"dc:description.abstract":["A flush-mounted heat exchanger concept, using the wing surface to dissipate heat, is investigated as a lower drag alternative to conventional ducted plate-fin radiators. A feasibility analysis is made for an unmanned high-altitude aircraft which will reach altitudes up to 25 kilometers. A computer code is used to calculate approximate heat transfer coefficients over the airfoil's surface. A model is tested in the Old Dominion University subsonic wind tunnel to verify the results of the computer code. The results indicate that a flush mounted heat exchanger design is able to provide 20 to 100 percent of the required heat dissipation at 25 kilometers altitude, depending upon which areas of the wing are considered usable. The attainable dissipation increases with decreasing altitude and with increasing angle of attack. The effect of surface heating on the boundary layer development is discussed. It is concluded that flush-mounted heat exchangers are a viable design option and are worthy of further study."],"dc:identifier":["https://digitalcommons.odu.edu/mae_etds/735"],"dc:rights":["<p>In Copyright. URI: <a href=\"http://rightsstatements.org/vocab/InC/1.0/\">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>"],"dc:subject":["Air ducts","Aerodynamic heating","Heat exchanges","Aerodynamics and Fluid Mechanics","Aeronautical Vehicles"],"dc:title":["Study of Surface Heat Exchangers for High-Altitude Atmospheric Research Aircraft"],"thesis:degree_discipline":["Mechanical & Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-27T04:11:35Z"}